OPC UA Set Publishing Mode Response Command
...
OPC UA Set Publishing Mode Request Command
...
OPC UA Delete Nodes Request Command
...
OPC UA Delete References Request Command
...
OPC UA Call Method Request Command
...
OPC UA Publish Request Command
...
OPC UA Delete References Response Command
...
OPC UA Monitored Item Modify Request Command
...
OPC UA Create Subscription Request Command
...
OPC UA Test Stack Ex Request Command
...
MatrikonOPC SCADA DNP3 Master Station Improper Input Validation
OVERVIEW This updated advisory was originally posted to the US-CERT secure Portal library on August 02, 2013, and is now being released to the ICS-CERT Web page. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation vulnerability in...
CVE-2013-0682
Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 do not properly handle exceptions, which allows remote attackers to cause a denial of service application crash or possibly execute...
Command injection
The DataSim and DataPid demonstration clients in Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 allow remote servers to cause a denial of service incorrect pointer access and client cra...
CVE-2013-0681
Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 allow remote attackers to cause a denial of service NULL pointer dereference and application crash via malformed data in a formatted text...
CVE-2013-0681
CVE-2013-0681 affects Cogent Real-Time Systems products (Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub Windows before 6.4.22, DataHub QuickTrend before 7.3.0). The issue is a NULL pointer dereference in the parser when handling malformed data in a formatted text command ...
CVE-2013-0683
CVE-2013-0683 concerns Cogent Real-Time Systems DataHub family. The DataSim/DataPid demonstration clients, OPC DataHub, Cascade DataHub (Windows), and DataHub QuickTrend are vulnerable to remote DoS via malformed data in a formatted text command, caused by a NULL pointer dereference in the parser...
OPC UA General Settings
OPC Unified Architecture is a common OLE for process control OPC...
Open Automation Software OPC Systems.NET Vulnerability
Overview This Advisory is a follow-up to “ICS-ALERT-11-285-01—Open Automation Software OPC Systems.NET Vulnerability” that was posted on the ICS-CERT website on October 12, 2011. Independent researcher Luigi Auriemma publicly reported a malformed packet vulnerability in Open Automation Software’s...
CVE-2012-0227
Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method...
Buffer overflow
Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method...