Lucene search
+L

8 matches found

osv_cve
osv_cve
•added 2020/08/17 4:15 p.m.•15 views

CVE-2020-13122

The novish command-line interface, included in NoviFlow NoviWare before NW500.2.12 and deployed on NoviSwitch devices, is vulnerable to command injection in the "show status destination ipaddr" command. This could be used by a read-only user monitoring group or admin to execute commands on the...

8.8CVSS7.4AI score0.07116EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/08/17 12:00 a.m.•8 views

CVE-2020-13122: Improper Neutralization of Special Elements used in an OS Command

The novish command-line interface, included in NoviFlow NoviWare before NW500.2.12 and deployed on NoviSwitch devices, is vulnerable to command injection in the "show status destination ipaddr" command. This could be used by a read-only user monitoring group or admin to execute commands on the...

8.8CVSS6.1AI score0.07116EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2020/08/17 12:00 a.m.•8 views

PT-2020-13340

Name of the Vulnerable Software and Affected Versions NoviFlow NoviWare versions prior to NW500.2.12 Description The novish command-line interface in NoviFlow NoviWare is susceptible to command injection via the "show status destination ipaddr" command. This issue could be exploited by a read-onl...

8.8CVSS0.07116EPSS
SaveExploits1References3
attackerkb
attackerkb
•added 2017/08/22 5:29 p.m.•11 views

CVE-2017-12785

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user monitor role to gain privileged root code execution on the...

10CVSS6.5AI score0.15988EPSS
SaveExploits4References2
osv_cve
osv_cve
•added 2017/08/22 5:29 p.m.•19 views

CVE-2017-12785

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user monitor role to gain privileged root code execution on the...

9.8CVSS6.5AI score0.15988EPSS
SaveExploits4References1
CVE
CVE
•added 2017/08/22 5:00 p.m.•84 views

CVE-2017-12785

The CVE-2017-12785 issue affects NoviFlow NoviWare NW400.2.6 and earlier on NoviSwitch devices. A vulnerability in the novish command-line interface allows a buffer overflow in the show log cli command, enabling a read-only (monitor) user to inject commands and gain privileged (root) code executi...

10CVSS10AI score0.15988EPSS
SaveExploits4References1Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/22 12:00 a.m.•5 views

CVE-2017-12785: Improper Restriction of Operations within the Bounds of a Memory Buffer

The novish command-line interface, included in the NoviWare software distribution through NW400.2.6 and deployed on NoviSwitch devices, is prone to a buffer overflow in the "show log cli" command. This could be used by a read-only user monitor role to gain privileged root code execution on the...

10CVSS6.4AI score0.15988EPSS
SaveExploits4References2
Positive Technologies
Positive Technologies
•added 2017/05/11 12:00 a.m.•4 views

PT-2017-2751

Name of the Vulnerable Software and Affected Versions NoviWare versions through NW400.2.6 Description The issue is related to a buffer overflow in the show log cli command of the novish command-line interface, which is part of the NoviWare software distribution. This could allow a read-only user ...

10CVSS0.15988EPSS
SaveExploits4References4
Rows per page
Query Builder