Lucene search
+L

343 matches found

CVE
CVE
added 2020/09/11 12:53 p.m.72 views

CVE-2020-16214

CVE-2020-16214 affects Philips PIC iX (PICiX) — versions B.02, C.02, C.03 — where user data saved to CSV files can include elements that are not properly neutralized, potentially enabling command interpretation when opened in spreadsheet software.Connected documents confirm the root cause: improp...

5.8CVSS5.5AI score0.00591EPSS
Exploits0References2Affected Software1
Positive Technologies
Positive Technologies
added 2020/09/11 12:0 a.m.14 views

PT-2020-14815 · Philips · Intellivue Mx750 +9

Name of the Vulnerable Software and Affected Versions: IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior Description: The product receives input or data but does not validate or incorrectly validates that the...

6.5CVSS6.4AI score0.00704EPSS
Exploits0References4
Positive Technologies
Positive Technologies
added 2020/09/11 12:0 a.m.9 views

PT-2020-14827 · Philips · Patient Information Center Ix +2

Name of the Vulnerable Software and Affected Versions: Patient Information Center iX PICiX versions C.02 and C.03 PerformanceBridge Focal Point version A.01 IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850 IntelliVue X3 versions N and prior Description: The software does not check or...

6.4CVSS6.3AI score0.00371EPSS
Exploits0References4
Citrix
Citrix
added 2020/07/31 12:0 a.m.10 views

FAQ: Where is the setting to enable multiple monitors?

Q:Where is the setting to enable multiple monitors? A : To enable multiple monitors edit the web.config file in the StoreWeb -directory on the StoreFront server. The default location isc:\inetpub\wwwroot\citrix\Storeweb. In the web.config file, change showDesktopViewer=true to...

7.1AI score
Exploits0
CISA
CISA
added 2020/03/05 12:0 a.m.12 views

NCSC Releases Advisory on Securing Internet-Connected Cameras

The United Kingdom UK National Cyber Security Centre NCSC has released an advisory on securing internet-connected cameras such as smart security cameras and baby monitors. An attacker could gain access to unsecured, or poorly secured, internet-connected cameras to obtain live feeds or images. The...

6.7AI score
Exploits0References5
Hacker One
Hacker One
added 2020/02/03 8:54 p.m.15 views

New Relic: Secure credentials values disclosure to regular users due to access control issue in monitor creating function

@skavans discovered a test endpoint for Syntethics monitors that did not properly validate the permissions of the user making the request. This could allow lesser privileged users on the same to account create monitors using Secure Credentials...

3.3AI score
Exploits0
Hacker One
Hacker One
added 2020/02/02 9:50 p.m.21 views

New Relic: Ability to run monitors' jobs of other accounts and to read these jobs content (including the secure credentials values)

@skavans identified an endpoint for testing Synthetics monitors. Without proper validation, this could allow monitors from other accounts to run on your account with knowledge of the monitor's ID: POST /accounts//monitors/monitor/recheck.json?monitorId= HTTP/1.1 Host: synthetics.newrelic.com...

3.9AI score
Exploits0
ICS
ICS
added 2020/01/23 12:0 a.m.50 views

GE CARESCAPE, ApexPro, and Clinical Information Center systems

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station CSCS and Clinical Information Center CIC systems, CARESCAPE B450, B650, B850 Monitors Vulnerabilities:...

10CVSS10AI score0.04932EPSS
Exploits0References5
Penetration Testing Lab
Penetration Testing Lab
added 2019/10/28 9:28 a.m.81 views

Persistence – Port Monitors

The print spooler service is responsible for managing printing jobs in Windows operating systems. Interaction with the service is performed through the Print Spooler API which contains a function AddMonitor that can be used to install local port monitors and connects the configuration, data and...

3.1AI score
Exploits0
NVD
NVD
added 2019/09/12 8:15 p.m.15 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.2CVSS7.1AI score0.00687EPSS
Exploits0References1
OSV
OSV
added 2019/09/12 8:15 p.m.3 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7.2CVSS5.8AI score0.01358EPSS
Exploits0References1
NVD
NVD
added 2019/09/12 8:15 p.m.16 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7.2CVSS7AI score0.01358EPSS
Exploits0References1
OSV
OSV
added 2019/09/12 8:15 p.m.7 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.2CVSS7.2AI score0.00687EPSS
Exploits0References1
Prion
Prion
added 2019/09/12 8:15 p.m.19 views

Design/Logic Flaw

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

6.5CVSS6.9AI score0.01358EPSS
Exploits0References1Affected Software4
Prion
Prion
added 2019/09/12 8:15 p.m.17 views

Code injection

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

6.5CVSS7AI score0.00687EPSS
Exploits0References1Affected Software4
Cvelist
Cvelist
added 2019/09/12 7:5 p.m.23 views

CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...

7AI score0.01358EPSS
Exploits0References1
CVE
CVE
added 2019/09/12 7:5 p.m.156 views

CVE-2019-13530

CVE-2019-13530 affects Philips IntelliVue WLAN portable patient monitors. Affected products include MP20‑MP90 (WLAN Version A, Firmware A.03.09), MP5/5SC (A.03.09), MP2/X2 and MX800/700/600 (WLAN Version B, Firmware A.01.09). The root cause is hard-coded credentials enabling FTP login to upload a...

7.2CVSS7AI score0.01358EPSS
Exploits0References1Affected Software1
CVE
CVE
added 2019/09/12 7:2 p.m.142 views

CVE-2019-13534

Philips IntelliVue WLAN portable patient monitors are affected by CVE-2019-13534. The vulnerability stems from the device downloading a file (code or firmware) from a remote location and executing it without sufficiently verifying the origin or integrity of the code. Affected products include Int...

7.2CVSS7.1AI score0.00687EPSS
Exploits0References1Affected Software1
Cvelist
Cvelist
added 2019/09/12 7:2 p.m.27 views

CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...

7.1AI score0.00687EPSS
Exploits0References1
Hacker One
Hacker One
added 2019/08/23 9:47 p.m.15 views

New Relic: User can run monitors at private locations, which he has no access to

@skavans discovered that insufficient validation was performed when configuring Synthetics monitors allowing deployment to arbitrary private locations with knowledge of the location ID: POST /accounts//validation.json HTTP/1.1 Host: synthetics.newrelic.com...

2AI score
Exploits0
Rows per page
Query Builder