343 matches found
CVE-2020-16214
CVE-2020-16214 affects Philips PIC iX (PICiX) — versions B.02, C.02, C.03 — where user data saved to CSV files can include elements that are not properly neutralized, potentially enabling command interpretation when opened in spreadsheet software.Connected documents confirm the root cause: improp...
PT-2020-14815 · Philips · Intellivue Mx750 +9
Name of the Vulnerable Software and Affected Versions: IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior Description: The product receives input or data but does not validate or incorrectly validates that the...
PT-2020-14827 · Philips · Patient Information Center Ix +2
Name of the Vulnerable Software and Affected Versions: Patient Information Center iX PICiX versions C.02 and C.03 PerformanceBridge Focal Point version A.01 IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850 IntelliVue X3 versions N and prior Description: The software does not check or...
FAQ: Where is the setting to enable multiple monitors?
Q:Where is the setting to enable multiple monitors? A : To enable multiple monitors edit the web.config file in the StoreWeb -directory on the StoreFront server. The default location isc:\inetpub\wwwroot\citrix\Storeweb. In the web.config file, change showDesktopViewer=true to...
NCSC Releases Advisory on Securing Internet-Connected Cameras
The United Kingdom UK National Cyber Security Centre NCSC has released an advisory on securing internet-connected cameras such as smart security cameras and baby monitors. An attacker could gain access to unsecured, or poorly secured, internet-connected cameras to obtain live feeds or images. The...
New Relic: Secure credentials values disclosure to regular users due to access control issue in monitor creating function
@skavans discovered a test endpoint for Syntethics monitors that did not properly validate the permissions of the user making the request. This could allow lesser privileged users on the same to account create monitors using Secure Credentials...
New Relic: Ability to run monitors' jobs of other accounts and to read these jobs content (including the secure credentials values)
@skavans identified an endpoint for testing Synthetics monitors. Without proper validation, this could allow monitors from other accounts to run on your account with knowledge of the monitor's ID: POST /accounts//monitors/monitor/recheck.json?monitorId= HTTP/1.1 Host: synthetics.newrelic.com...
GE CARESCAPE, ApexPro, and Clinical Information Center systems
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: GE Equipment: CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station CSCS and Clinical Information Center CIC systems, CARESCAPE B450, B650, B850 Monitors Vulnerabilities:...
Persistence – Port Monitors
The print spooler service is responsible for managing printing jobs in Windows operating systems. Interaction with the service is performed through the Print Spooler API which contains a function AddMonitor that can be used to install local port monitors and connects the configuration, data and...
CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...
CVE-2019-13530
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...
CVE-2019-13530
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...
CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...
Design/Logic Flaw
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...
Code injection
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...
CVE-2019-13530
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. An attacker can us...
CVE-2019-13530
CVE-2019-13530 affects Philips IntelliVue WLAN portable patient monitors. Affected products include MP20‑MP90 (WLAN Version A, Firmware A.03.09), MP5/5SC (A.03.09), MP2/X2 and MX800/700/600 (WLAN Version B, Firmware A.01.09). The root cause is hard-coded credentials enabling FTP login to upload a...
CVE-2019-13534
Philips IntelliVue WLAN portable patient monitors are affected by CVE-2019-13534. The vulnerability stems from the device downloading a file (code or firmware) from a remote location and executing it without sufficiently verifying the origin or integrity of the code. Affected products include Int...
CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part : M8096-67501, WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C and WLAN Version B, Firmware A.01.09, Part : N/A Replaced by Version C. The product...
New Relic: User can run monitors at private locations, which he has no access to
@skavans discovered that insufficient validation was performed when configuring Synthetics monitors allowing deployment to arbitrary private locations with knowledge of the location ID: POST /accounts//validation.json HTTP/1.1 Host: synthetics.newrelic.com...