345 matches found
CVE-2026-64621
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
CVE-2026-64621
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
CVE-2026-64621
FreeRDP before 3.28.0 (affected 3.x through 3.27.1) contains a size-controlled double-free in freerdp_client_rdp_file_apply_to_settings() when parsing the selectedmonitors field in an .rdp file. The MonitorIds array is allocated via the settings object and a raw pointer is freed on the strtoul er...
CVE-2026-64621 FreeRDP before 3.28.0 Double-Free via selectedmonitors
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
CVE-2026-64621
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
New TrojPix Attack Leaks Data From Air-Gapped Systems via Video Cable Emissions
Researchers at Shandong University have shown a fast new way to pull data off computers that are cut off from every network. The technique, called TrojPix, tweaks on-screen pixels in ways the eye cannot see, so that the video cable carrying them radiates a faint radio signal a nearby receiver can...
CVE-2026-32673
A vulnerability exists in BIG-IP scripted monitors that may allow an authenticated attacker with the Resource Administrator or Administrator role to execute arbitrary system commands with higher privileges. In appliance mode deployments, a successful exploit can allow the attacker to cross a...
CVE-2022-4992
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2022-4992
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
EUVD-2019-20160
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25717
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...
EUVD-2019-20156
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25717
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...
CVE-2019-25717
CVE-2019-25717 affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. The vulnerability allows unauthenticated attackers over a network to access exposed log files, exposing device internals, location data, and wired network configuration details. No root cause or remediation detail...
CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...
PT-2026-45862
Name of the Vulnerable Software and Affected Versions Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions prior to VG4.2 Description A network message handling issue allows remote attackers to inject spoofed or tampered data. This can lead to denial-of-service...