Lucene search
+L

345 matches found

NVD
NVD
added 2026/07/20 12:19 p.m.14 views

CVE-2026-64621

FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...

9.3CVSS0.00304EPSS
SaveExploits1References3
ATTACKERKB
ATTACKERKB
added 2026/07/20 12:4 p.m.6 views

CVE-2026-64621

FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...

9.3CVSS5.5AI score0.00304EPSS
SaveExploits1References4
CVE
CVE
added 2026/07/20 12:4 p.m.19 views

CVE-2026-64621

FreeRDP before 3.28.0 (affected 3.x through 3.27.1) contains a size-controlled double-free in freerdp_client_rdp_file_apply_to_settings() when parsing the selectedmonitors field in an .rdp file. The MonitorIds array is allocated via the settings object and a raw pointer is freed on the strtoul er...

9.3CVSS5.5AI score0.00304EPSS
SaveExploits1References3Affected Software1
OSV
OSV
added 2026/07/20 12:4 p.m.7 views

CVE-2026-64621 FreeRDP before 3.28.0 Double-Free via selectedmonitors

FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...

9.3CVSS5.5AI score
SaveExploits0References5
Debian CVE
Debian CVE
added 2026/07/20 12:4 p.m.6 views

CVE-2026-64621

FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...

9.3CVSS5.5AI score0.00304EPSS
SaveExploits1
The Hacker News
The Hacker News
added 2026/07/06 8:50 a.m.24 views

New TrojPix Attack Leaks Data From Air-Gapped Systems via Video Cable Emissions

Researchers at Shandong University have shown a fast new way to pull data off computers that are cut off from every network. The technique, called TrojPix, tweaks on-screen pixels in ways the eye cannot see, so that the video cable carrying them radiates a faint radio signal a nearby receiver can...

6AI score
SaveExploits0
RedhatCVE
RedhatCVE
added 2026/06/05 7:20 p.m.18 views

CVE-2026-32673

A vulnerability exists in BIG-IP scripted monitors that may allow an authenticated attacker with the Resource Administrator or Administrator role to execute arbitrary system commands with higher privileges. In appliance mode deployments, a successful exploit can allow the attacker to cross a...

8.7CVSS5.6AI score0.00235EPSS
SaveExploits0References1
NVD
NVD
added 2026/06/02 10:16 p.m.26 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.0016EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/06/02 9:6 p.m.10 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.0016EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2026/06/02 9:6 p.m.45 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.0016EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2026/06/02 7:11 p.m.11 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/06/02 7:11 p.m.18 views

EUVD-2019-20160

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00175EPSS
SaveExploits0References2
NVD
NVD
added 2026/06/02 2:16 p.m.16 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS0.00132EPSS
SaveExploits0References2
NVD
NVD
added 2026/06/02 2:16 p.m.21 views

CVE-2019-25717

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00203EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/06/02 2:0 p.m.18 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2026/06/02 2:0 p.m.50 views

CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS0.00132EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/06/02 1:42 p.m.11 views

CVE-2019-25717

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS5.8AI score0.00203EPSS
SaveExploits0References3
CVE
CVE
added 2026/06/02 1:42 p.m.26 views

CVE-2019-25717

CVE-2019-25717 affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. The vulnerability allows unauthenticated attackers over a network to access exposed log files, exposing device internals, location data, and wired network configuration details. No root cause or remediation detail...

5.3CVSS5.8AI score0.00203EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2026/06/02 1:42 p.m.45 views

CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00203EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2026/06/02 12:0 a.m.31 views

PT-2026-45862

Name of the Vulnerable Software and Affected Versions Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions prior to VG4.2 Description A network message handling issue allows remote attackers to inject spoofed or tampered data. This can lead to denial-of-service...

8.8CVSS5.8AI score0.0016EPSS
SaveExploits0References4
Rows per page
Query Builder