350 matches found
Hale
Informazioni Hale è un monitor/spia per botnet command & control con un design modulare per sviluppare facilmente nuovi moduli che monitorano nuovi protocolli usati dai server C&C. Hale include monitor IRC e HTTP sviluppati con Twisted per gestire la scalabilità di un grande numero di connessioni...
CVE-2026-68155
In the Linux kernel, the following vulnerability has been resolved: libceph: Reject monmaps advertising zero monitors A message of type CEPHMSGMONMAP contains a monmap that is sent from a monitor to the client. This monmap contains information about the existing monitors in the cluster. Currently...
CVE-2026-68155
CVE-2026-68155 affects the Linux kernel libceph component. A crafted monmap advertising zero monitors can be treated as valid, potentially crashing the client when opening a session (DoS) due to BUG_ON(monc->monmap->num_mon
EUVD-2026-55541
In the Linux kernel, the following vulnerability has been resolved: libceph: Reject monmaps advertising zero monitors A message of type CEPHMSGMONMAP contains a monmap that is sent from a monitor to the client. This monmap contains information about the existing monitors in the cluster. Currently...
CVE-2026-68155 libceph: Reject monmaps advertising zero monitors
In the Linux kernel, the following vulnerability has been resolved: libceph: Reject monmaps advertising zero monitors A message of type CEPHMSGMONMAP contains a monmap that is sent from a monitor to the client. This monmap contains information about the existing monitors in the cluster. Currently...
CVE-2026-64621
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
CVE-2026-64621
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
CVE-2026-64621
FreeRDP before 3.28.0 (affected 3.x through 3.27.1) contains a size-controlled double-free in freerdp_client_rdp_file_apply_to_settings() when parsing the selectedmonitors field in an .rdp file. The MonitorIds array is allocated via the settings object and a raw pointer is freed on the strtoul er...
CVE-2026-64621 FreeRDP before 3.28.0 Double-Free via selectedmonitors
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
CVE-2026-64621
FreeRDP before 3.28.0 affected 3.x through 3.27.1 contains a double-free vulnerability in freerdpclientrdpfileapplytosettings client/common/file.c when parsing the selectedmonitors field of a .rdp connection file. The MonitorIds array is allocated through the settings object, and a raw non-owning...
New TrojPix Attack Leaks Data From Air-Gapped Systems via Video Cable Emissions
Researchers at Shandong University have shown a fast new way to pull data off computers that are cut off from every network. The technique, called TrojPix, tweaks on-screen pixels in ways the eye cannot see, so that the video cable carrying them radiates a faint radio signal a nearby receiver can...
CVE-2026-32673
A vulnerability exists in BIG-IP scripted monitors that may allow an authenticated attacker with the Resource Administrator or Administrator role to execute arbitrary system commands with higher privileges. In appliance mode deployments, a successful exploit can allow the attacker to cross a...
CVE-2022-4992
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2022-4992
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
EUVD-2019-20160
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
CVE-2019-25717
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...
EUVD-2019-20156
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...