Schneider Electric Modicon Controllers Use of Insufficiently Random Values (CVE-2019-6821)
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. This plugin only works...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2018-7857)
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. This plugin only works with Tenable.ot...
Schneider Electric Web Server on Modicon M340 Out-of-Bounds Read (CVE-2020-7562)
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...
Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6841)
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware version prior to V3.10, Modicon M340 all firmware versions, and Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading...
Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6847)
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2018-7849)
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus. This plugin only works with...
Schneider Electric Modicon Controllers Improper Access Control (CVE-2018-7847)
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus. This plugin only wor...
Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2019-6819)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6808)
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus. This plugin only works with Tenable.ot...
Schneider Electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2012-0929)
Multiple buffer overflows in Schneider Electric Modicon Quantum PLC allow remote attackers to cause a denial of service via malformed requests to the 1 FTP server or 2 HTTP server. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more informatio...
Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6848)
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU BMEx58 and Modicon M580 communication module BMENOC0311, BMENOC0321 see notification for version info, which could cause a Denial of Service attack on the PLC when sending specific data on the REST API...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6828)
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 firmware version prior to V2.90, Modicon M340 firmware version prior to V3.10, Modicon Premium all versions, and Modicon Quantum all versions, which could cause a possible denial of service when reading specific coils and registers i...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2018-7855)
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus This plugin only works with Tenable.ot. Please...
Schneider Electric Modicon M221 PLCs and SoMachine Basic Protection Mechanism Failure (CVE-2017-7575)
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port 502/tcp. Subsequently the application may be arbitrarily downloaded, modified, and uploaded...
Schneider Electric Modicon Credentials Management Errors (CVE-2018-7788)
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2018-7833)
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can send a specially crafted XML data via a POST request to cause the web server to become unavailable...
Schneider Electric Modicon Cross-site Scripting (CVE-2018-7810)
An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browse...
Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6843)
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware version prior to V3.10, Modicon M340 all firmware versions, and Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6809)
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 firmware versions prior to V2.90, Modicon M340 firmware versions prior to V3.10, Modicon Premium all versions, Modicon Quantum all versions, which could cause a possible denial of service when reading invalid data from the...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2018-7852)
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus. This plugin only works with Tenable.ot...