Lucene search

K
nessusThis script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2018-7843.NASL
HistoryFeb 07, 2022 - 12:00 a.m.

Schneider Electric Modicon Out-of-bounds Read (CVE-2018-7843)

2022-02-0700:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
8

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:N/I:N/A:P

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

0.001 Low

EPSS

Percentile

48.8%

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500246);
  script_version("1.6");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/24");

  script_cve_id("CVE-2018-7843");

  script_name(english:"Schneider Electric Modicon Out-of-bounds Read (CVE-2018-7843)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum,
and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an
invalid data offset in the controller over Modbus.  

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  # https://www.talosintelligence.com/vulnerability_reports/TALOS-2018-0738
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?7af3a1b8");
  # https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-134-11
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?a432fe19");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-7843");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");
  script_cwe_id(125);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/05/22");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/05/22");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_quantum_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_premium_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:modicon_m580_series_firmware" :
        {"versionEndExcluding" : "2.80", "family" : "ModiconM580"},
    "cpe:/o:schneider-electric:modicon_m340_series_firmware" :
        {"versionEndExcluding" : "3.10", "family" : "ModiconM340"},
    "cpe:/o:schneider-electric:modicon_quantum_firmware" :
        {"versionEndExcluding" : "3.60", "family" : "QuantumUnity"},
    "cpe:/o:schneider-electric:modicon_premium_firmware" :
        {"versionEndExcluding" : "3.20", "family" : "Premium"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
schneider-electricmodicon_m580_series_firmwarecpe:/o:schneider-electric:modicon_m580_series_firmware
schneider-electricmodicon_m340_series_firmwarecpe:/o:schneider-electric:modicon_m340_series_firmware
schneider-electricmodicon_quantum_firmwarecpe:/o:schneider-electric:modicon_quantum_firmware
schneider-electricmodicon_premium_firmwarecpe:/o:schneider-electric:modicon_premium_firmware

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:N/I:N/A:P

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

0.001 Low

EPSS

Percentile

48.8%

Related for TENABLE_OT_SCHNEIDER_CVE-2018-7843.NASL