Tenable Nessus
Tenable Nessus
added 2024/11/13 12:0 a.m.12 views

Siemens SCALANCE M-800 Family Improper Input Validation (CVE-2024-50560)

Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...

4.3CVSS7.7AI score0.00273EPSS
SaveExploits0References7
Tenable Nessus
Tenable Nessus
added 2024/11/13 12:0 a.m.19 views

Siemens SCALANCE M-800 Family Improper Limitation of a Pathname to a Restricted Directory (CVE-2024-50559)

Affected devices do not properly validate the filenames of the certificate. This could allow an authenticated remote attacker to append arbitrary values which will lead to compromise of integrity of the system. This plugin only works with Tenable.ot. Please visit...

5.1CVSS8AI score0.00265EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2024/11/12 12:0 a.m.6 views

Siemens多款产品 访问控制错误漏洞

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. An access control error vulnerability exists in multiple Siemens products that can be exploited by an attacker to cause a temporary denial of service condition...

5.3CVSS6.7AI score0.00304EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/11/12 12:0 a.m.8 views

Siemens多款产品 路径遍历漏洞

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. A path traversal vulnerability exists in multiple Siemens products, which can be exploited by an attacker to append arbitrary values, resulting in a compromise of system integrity...

5.1CVSS7AI score0.00265EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/11/12 12:0 a.m.6 views

Siemens多款产品 安全漏洞

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. An input validation error vulnerability exists in multiple Siemens products, which can be exploited by an attacker to execute arbitrary code on the device...

9.8CVSS7.8AI score0.00869EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/11/12 12:0 a.m.6 views

Siemens RUGGEDCOM和Siemens SCALANCE 输入验证错误漏洞

SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers. An input validation error vulnerability exists in multiple Siemens products and can be exploited by attackers to compromise system integrity...

4.3CVSS6.9AI score0.00273EPSS
SaveExploits0References3
ICS
ICS
added 2024/11/12 12:0 a.m.13 views

Siemens SCALANCE M-800 Family

SUMMARY SCALANCE M-800 family before V8.2 is affected by multiple vulnerabilities. Siemens has released new versions for the affected products and recommends to update to the latest versions. 2. GENERAL RECOMMENDATIONS As a general security measure, Siemens strongly recommends to protect network...

9.6AI score
SaveExploits0References10
BDU FSTEC
BDU FSTEC
added 2024/10/31 12:0 a.m.7 views

The vulnerability of the microprogrammed software of the SCALANCE M-800 industrial routers stems from incorrect processing of input data in the configuration fields of VPNs. This allows attackers to execute arbitrary code.

The vulnerability of the microprogrammed software of the SCALANCE M-800 industrial routers is related to incorrect processing of input data in the configuration fields of VPNs. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...

9CVSS5.9AI score0.00768EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2024/10/31 12:0 a.m.11 views

The vulnerability of the microprogrammed software of industrial routers SCALANCE M-800, related to insufficient protection of registration data, allows a hacker to replace other users’ 2FA tokens and expose the protected information.

The vulnerability of the microprogrammed software in industrial routers SCALANCE M-800 is related to insufficient protection for registration data. Exploiting this vulnerability could allow a hacker to replace other users’ 2FA tokens and expose the protected information...

6.8CVSS5.5AI score0.00488EPSS
SaveExploits0References3Affected Software1
ICS
ICS
added 2024/08/13 12:0 a.m.47 views

Siemens SCALANCE M-800, RUGGEDCOM RM1224

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

8.8CVSS8.4AI score0.01001EPSS
SaveExploits0References10
CNVD
CNVD
added 2023/12/13 12:0 a.m.78 views

Siemens SCALANCE M-800/S615 Series OS Command Injection Vulnerability

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers. An operating system command injection vulnerability exists in the Siemens SCALANCE M-800/S615 series, which can be exploited by an attacker to execute commands on the system...

7.2CVSS7.6AI score0.00644EPSS
SaveExploits0References1
CNVD
CNVD
added 2023/12/13 12:0 a.m.50 views

Siemens SCALANCE M-800/S615 Series OS Command Injection Vulnerability

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers. An operating system command injection vulnerability exists in the Siemens SCALANCE M-800/S615 series, which can be exploited by an attacker to execute commands on the system via a malicious local administrator...

7.2CVSS7.3AI score0.00623EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/12/12 12:0 a.m.6 views

Siemens RUGGEDCOM RM1224 操作系统命令注入漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers. An operating system command injection vulnerability exists in the Siemens SCALANCE M-800/S615 series, which can be exploited by an attacker to execute commands on the system via a malicious local administrator...

7.2CVSS7.6AI score0.00623EPSS
SaveExploits0References4
CNNVD
CNNVD
added 2023/11/14 12:0 a.m.6 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.6CVSS7.7AI score0.00376EPSS
SaveExploits0References7
CNNVD
CNNVD
added 2023/11/14 12:0 a.m.6 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

8.8CVSS7AI score0.00666EPSS
SaveExploits0References6
CNNVD
CNNVD
added 2023/11/14 12:0 a.m.9 views

Siemens SCALANCE 注入漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

9.4CVSS7.1AI score0.01352EPSS
SaveExploits0References8
Tenable Nessus
Tenable Nessus
added 2023/04/11 12:0 a.m.30 views

Siemens SCALANCE M-800 & S615 Sensitive Cookie in HTTPS Session Without 'Secure' Attribute (CVE-2016-7090)

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session. This...

4.3CVSS5.1AI score0.01895EPSS
SaveExploits0References4
CNVD
CNVD
added 2022/12/14 12:0 a.m.41 views

Siemens SCALANCE M-800/S615 Series Information Disclosure Vulnerability

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers. An information disclosure vulnerability exists in the Siemens SCALANCE M-800/S615 series due to the affected devices not properly checking the TFTP block size. An attacker who is allowed to authenticate could...

5.1CVSS6.2AI score0.007EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2022/12/13 12:0 a.m.8 views

Siemens部分产品 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers. An information disclosure vulnerability exists in the Siemens SCALANCE M-800/S615 series due to the affected devices not properly checking the TFTP block size. An attacker who is allowed to authenticate could...

5.1CVSS6.3AI score0.007EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2022/08/09 12:0 a.m.7 views

PT-2022-4147 · Siemens · Scalance W-700 +9

Name of the Vulnerable Software and Affected Versions: SCALANCE M-800 / S615 versions prior to V2.3.1 SCALANCE SC-600 family versions prior to V2.3.1 SCALANCE W-1700 IEEE 802.11ac family versions prior to V2.3.1 SCALANCE W-700 IEEE 802.11ax family versions prior to V2.3.1 SCALANCE W-700 IEEE...

9CVSS5.4AI score0.0081EPSS
SaveExploits0References4