Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SIEMENS_CVE-2016-7090.NASL
HistoryApr 11, 2023 - 12:00 a.m.

Siemens SCALANCE M-800 & S615 Sensitive Cookie in HTTPS Session Without 'Secure' Attribute (CVE-2016-7090)

2023-04-1100:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
10
siemens
scalance m-800
s615 modules
firmware
cve-2016-7090
vulnerability
https
session
secure flag

0.003 Low

EPSS

Percentile

71.1%

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501031);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/08/24");

  script_cve_id("CVE-2016-7090");

  script_name(english:"Siemens SCALANCE M-800 & S615 Sensitive Cookie in HTTPS Session Without 'Secure' Attribute (CVE-2016-7090)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"The integrated web server on Siemens SCALANCE M-800 and S615 modules
with firmware before 4.02 does not set the secure flag for the session
cookie in an https session, which makes it easier for remote attackers
to capture this cookie by intercepting its transmission within an http
session.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/93115");
  # https://cert-portal.siemens.com/productcert/pdf/ssa-342135.pdf
  script_set_attribute(attribute:"see_also", value:"https://www.nessus.org/u?9d6a127d");
  script_set_attribute(attribute:"see_also", value:"https://ics-cert.us-cert.gov/advisories/ICSA-16-271-01");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:N/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2016-7090");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(200);

  script_set_attribute(attribute:"vuln_publication_date", value:"2016/09/29");
  script_set_attribute(attribute:"patch_publication_date", value:"2016/09/29");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/04/11");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_m-800_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_s615_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_m-800_series_firmware" :
        {"versionEndIncluding" : "4.01", "family" : "SCALANCEM"},
    "cpe:/o:siemens:scalance_s615_firmware" :
        {"versionEndIncluding" : "4.01", "family" : "SCALANCES"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
VendorProductVersionCPE
siemensscalance_m-800_series_firmwarecpe:/o:siemens:scalance_m-800_series_firmware
siemensscalance_s615_firmwarecpe:/o:siemens:scalance_s615_firmware

0.003 Low

EPSS

Percentile

71.1%

Related for TENABLE_OT_SIEMENS_CVE-2016-7090.NASL