Lucene search
+L

10334 matches found

Positive Technologies
Positive Technologies
•added 2018/06/05 12:00 a.m.•2 views

PT-2018-5080

Name of the Vulnerable Software and Affected Versions ManageEngine Applications Manager versions 12 and 13 before build 13200 Description The issue is related to a Reflected Cross-Site Scripting problem. It affects the parameter LIMIT in the URL path "/DiagAlertAction.do?REQTYPE=AJAX&LIMIT=1233"...

6.1CVSS0.01732EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/06/05 12:00 a.m.•4 views

CVE-2016-9490: Improper Neutralization of Input During Web Page Generation

ManageEngine Applications Manager versions 12 and 13 before build 13200 suffer from a Reflected Cross-Site Scripting vulnerability. Applications Manager is prone to a Cross-Site Scripting vulnerability in parameter LIMIT, in URL path /DiagAlertAction.do?REQTYPE=AJAX&LIMIT=1233. The URL is also...

6.1CVSS6.8AI score0.01732EPSS
SaveExploits0References3
OpenVAS
OpenVAS
•added 2018/06/01 12:00 a.m.•282 views

Microsoft Windows: Interactive logon: Machine inactivity limit

This test checks the setting for policy OpenVAS Vulnerability Test $Id: winilmachineinactivitylimit.nasl 11532 2018-09-21 19:07:30Z cfischer $ Check value for Interactive logon: Machine inactivity limit Authors: Emanuel Moss Copyright: Copyright c 2018 Greenbone Networks GmbH,...

7.3AI score
SaveExploits0
Mend
Mend
•added 2018/05/31 8:00 p.m.•3 views

CVE-2016-10550

sequelize is an Object-relational mapping, or a middleman to convert things from Postgres, MySQL, MariaDB, SQLite and Microsoft SQL Server into usable data for NodeJS If user input goes into the "limit" or "order" parameters, a malicious user can put in their own SQL statements. This affects...

9.8CVSS0.01884EPSS
SaveExploits0References5
CVE
CVE
•added 2018/05/31 8:00 p.m.•75 views

CVE-2016-10550

The CVE-2016-10550 issue affects sequelize (ORM for Node.js) where user input into limit or order parameters can be used to inject SQL. Concrete details across documents show affected version: 3.16.0 and earlier. Root cause is improper handling of input in query construction, enabling SQL stateme...

9.8CVSS9.5AI score0.01884EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
•added 2018/05/31 12:00 a.m.•5 views

PT-2018-4728

Name of the Vulnerable Software and Affected Versions sequelize versions 3.16.0 and earlier Description The issue concerns SQL Injection where user input is passed into the limit or order parameters of sequelize query calls, such as findOne or findAll. This allows a malicious user to inject their...

9.8CVSS0.01884EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/05/31 12:00 a.m.•4 views

CVE-2016-10550: Improper Neutralization of Special Elements used in an SQL Command

sequelize is an Object-relational mapping, or a middleman to convert things from Postgres, MySQL, MariaDB, SQLite and Microsoft SQL Server into usable data for NodeJS If user input goes into the limit or order parameters, a malicious user can put in their own SQL statements. This affects sequeliz...

9.8CVSS8.2AI score0.01884EPSS
SaveExploits0References3
OpenVAS
OpenVAS
•added 2018/05/29 12:00 a.m.•19 views

Windows Defender Firewall: Logfile size limit

This test checks the setting for policy OpenVAS Vulnerability Test $Id: winadvsecprofilelogfilesize.nasl 10010 2018-05-29 14:43:35Z emoss $ Check value for Windows Defender Firewall: logfile size limit Authors: Emanuel Moss Copyright: Copyright c 2018 Greenbone Networks GmbH,...

7.3AI score
SaveExploits0
Hacker One
Hacker One
•added 2018/05/12 11:16 a.m.•25 views

Greenhouse.io: Bypass of request line length limit to DoS via cache poisoning

Summary This is a bypass of the fix that was introduced in response to report 334709. The bug in question was that it was possible to poison the cache of the generated JS file at https://boards.greenhouse.io/embed/jobboard/js?for=surveymonkey, by appending a URL-encoded NULL byte %00, followed by...

7.2AI score
SaveExploits0
OpenVAS
OpenVAS
•added 2018/05/04 12:00 a.m.•174 views

Microsoft Windows 10: Accounts: Limit local account use of blank passwords to console logon only

The Accounts: Limit local account use of blank passwords to console logon only policy setting determines whether remote interactive logons by network services such as Remote Desktop Services, Telnet, and File Transfer Protocol FTP are allowed for local accounts that have blank passwords. If this...

7.4AI score
SaveExploits0
UbuntuCve
UbuntuCve
•added 2018/04/25 1:29 p.m.•30 views

CVE-2017-7652

In Eclipse Mosquitto 1.4.14, if a Mosquitto instance is set running with a configuration file, then sending a HUP signal to server triggers the configuration to be reloaded from disk. If there are lots of clients connected so that there are no more file descriptors/sockets available default limit...

7.5CVSS7AI score0.01621EPSS
SaveExploits0References2
OSV
OSV
•added 2018/04/25 1:29 p.m.•12 views

UBUNTU-CVE-2017-7652

In Eclipse Mosquitto 1.4.14, if a Mosquitto instance is set running with a configuration file, then sending a HUP signal to server triggers the configuration to be reloaded from disk. If there are lots of clients connected so that there are no more file descriptors/sockets available default limit...

7.5CVSS7.1AI score0.01621EPSS
SaveExploits0References3
OSV
OSV
•added 2018/04/25 1:29 p.m.•9 views

ALPINE-CVE-2017-7652

In Eclipse Mosquitto 1.4.14, if a Mosquitto instance is set running with a configuration file, then sending a HUP signal to server triggers the configuration to be reloaded from disk. If there are lots of clients connected so that there are no more file descriptors/sockets available default limit...

7.5CVSS6.8AI score0.01621EPSS
SaveExploits0References1
CVE
CVE
•added 2018/04/25 1:00 p.m.•113 views

CVE-2017-7652

CVE-2017-7652 affects Eclipse Mosquitto (notably around version 1.4.14) where reloading configuration on SIGHUP can exhaust file descriptors/sockets, preventing opening the config file. Publicly documented impact includes potential configuration reload failures due to FD exhaustion. Remediation g...

7.5CVSS7.2AI score0.01621EPSS
SaveExploits0References5Affected Software1
CNVD
CNVD
•added 2018/04/17 12:00 a.m.•17 views

Multiple F5 Products Elevation of Privilege Vulnerabilities

F5 BIG-IP LTM, etc. are products of F5 Corporation, U.S.A. F5 BIG-IP LTM is a local traffic manager; BIG-IP AAM is an application acceleration manager. A security vulnerability exists in a number of F5 products that stems from the program's failure to enforce a limit on the commands that can be...

7.2CVSS6.8AI score0.14212EPSS
SaveExploits3References1
OSV
OSV
•added 2018/04/16 3:31 p.m.•14 views

SUSE-SU-2018:0956-1 Security update for ntp

This update for ntp fixes the following issues: - Update to 4.2.8p11 bsc1082210: CVE-2016-1549: Sybil vulnerability: ephemeral association attack. While fixed in ntp-4.2.8p7, there are significant additional protections for this issue in 4.2.8p11. CVE-2018-7182: ctlgetitem: buffer read overrun...

9.8CVSS8.1AI score0.28834EPSS
SaveExploits6References15
Prion
Prion
•added 2018/04/16 3:29 p.m.•36 views

Design/Logic Flaw

openshift before versions 3.3.1.11, 3.2.1.23, 3.4 is vulnerable to a flaw when a volume fails to detach, which causes the delete operation to fail with 'VolumeInUse' error. Since the delete operation is retried every 30 seconds for each volume, this could lead to a denial of service attack as the...

4CVSS7AI score0.01237EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2018/04/16 2:00 p.m.•68 views

CVE-2016-9592

The CVE-2016-9592 entry describes a denial-of-service risk in OpenShift before versions 3.3.1.11, 3.2.1.23, and 3.4. The root cause is a flaw where a volume fails to detach, causing the delete operation to fail with a VolumeInUse error. Because the delete operation is retried every 30 seconds for...

4.3CVSS4.6AI score0.01237EPSS
SaveExploits0References2Affected Software1
Positive Technologies
Positive Technologies
•added 2018/04/16 12:00 a.m.•4 views

PT-2018-5104

Name of the Vulnerable Software and Affected Versions openshift versions prior to 3.3.1.11 openshift versions prior to 3.2.1.23 openshift versions prior to 3.4 Description The issue arises when a volume fails to detach, resulting in a 'VolumeInUse' error during the delete operation. As the delete...

4.3CVSS0.01237EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/04/16 12:00 a.m.•7 views

CVE-2016-9592: Improper Cleanup on Thrown Exception

openshift before versions 3.3.1.11, 3.2.1.23, 3.4 is vulnerable to a flaw when a volume fails to detach, which causes the delete operation to fail with 'VolumeInUse' error. Since the delete operation is retried every 30 seconds for each volume, this could lead to a denial of service attack as the...

4.3CVSS5.4AI score0.01237EPSS
SaveExploits0References3