Medtronic's MiniMed 600 series insulin pumps potentially at risk of compromise, says FDA

The US FDA Food and Drug Administration has warned users of Medtronic's MiniMed 600 Series Insulin Pump System--specifically, models for MiniMed 630G and MiniMed 670G--that their medical devices have a cybersecurity issue with its communication protocol. If compromised, attackers could gain...

2.2AI score
Exploits0
NVD
NVD
added 2021/12/01 4:15 p.m.22 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS0.00477EPSS
Exploits0References2
Prion
Prion
added 2021/12/01 4:15 p.m.16 views

Authentication flaw

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

4.8CVSS8AI score0.00477EPSS
Exploits0References2
Cvelist
Cvelist
added 2021/12/01 3:38 p.m.31 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

7.3CVSS8.1AI score0.00477EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2021/12/01 12:0 a.m.5 views

PT-2021-9161 · Insulet · Insulet Omnipod Insulin Management System

Name of the Vulnerable Software and Affected Versions: Insulet Omnipod Insulin Management System versions with product ID 19191 and 40160 Description: The wireless RF communication protocol used by the Insulet Omnipod Insulin Management System does not properly implement authentication or...

8.1CVSS7.8AI score0.00477EPSS
Exploits0References4
NVD
NVD
added 2019/06/28 9:15 p.m.25 views

CVE-2019-10964

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker...

8.8CVSS8.8AI score0.01234EPSS
Exploits0References4
OSV
OSV
added 2019/06/28 9:15 p.m.3 views

CVE-2019-10964

Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker...

8.8CVSS5.8AI score0.01234EPSS
Exploits0References4
Prion
Prion
added 2019/06/28 9:15 p.m.23 views

Authentication flaw

In Medtronic MinMed 508 and Medtronic Minimed Paradigm Insulin Pumps, Versions, MiniMed 508 pump – All versions, MiniMed Paradigm 511 pump – All versions, MiniMed Paradigm 512/712 pumps – All versions, MiniMed Paradigm 712E pump–All versions, MiniMed Paradigm 515/715 pumps–All versions, MiniMed...

5.8CVSS8.7AI score0.01234EPSS
Exploits0References2Affected Software7
CVE
CVE
added 2019/06/28 8:58 p.m.78 views

CVE-2019-10964

CVE-2019-10964 affects Medtronic MiniMed insulin pumps (508 and Paradigm series, and related models) via an improper access control weakness in wireless RF communications. The vulnerability allows an attacker with adjacent access to inject, replay, modify, or intercept data and potentially change...

8.8CVSS7.2AI score0.01234EPSS
Exploits0References4Affected Software1
CNVD
CNVD
added 2018/08/14 12:0 a.m.3 views

Multiple Medtronic Product Information Disclosure Vulnerabilities

Medtronic MMT-508 MiniMed insulin pump and others are different models of insulin pumps from Medtronic, USA. An information disclosure vulnerability exists in several Medtronic products, which can be exploited by an attacker to capture the information passed between the controller and pump when t...

5.3CVSS5.2AI score0.00712EPSS
Exploits0References1
Prion
Prion
added 2018/08/13 9:48 p.m.18 views

Default configuration

Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the "easy bolus" and "remote bolus" options...

2.9CVSS5.2AI score0.00712EPSS
Exploits0References2
ICS
ICS
added 2018/08/07 12:0 a.m.48 views

Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.3 Vendor: Medtronic --------- Begin Update A Part 1 of 3 -------- Equipment: Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers --------- End Update A Part 1 of 3 -------- Vulnerabilities: Cleartext Transmission of Sensitive Information, Authentication Bypass...

5.9AI score
Exploits0References5
Rows per page
Query Builder