Lucene search
K

9 matches found

OSV
OSV
added 2022/06/20 6:20 p.m.6 views

MAL-2022-362 Malicious code in @insulet/fetlife-assets (npm)

--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware 13c249b49fc7cbbfb6d0edfa283b1bb792100c43775b5d1a0fed55501b1dbb1b Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...

7AI score
Exploits0References1
OSSF Malicious Packages
OSSF Malicious Packages
added 2022/06/20 6:20 p.m.2 views

Malicious code in @insulet/fetlife-assets (npm)

--- -= Per source details. Do not edit below this line.=- Source: ghsa-malware 13c249b49fc7cbbfb6d0edfa283b1bb792100c43775b5d1a0fed55501b1dbb1b Any computer that has this package installed or running should be considered fully compromised. All secrets and keys stored on that computer should be...

6.9AI score
Exploits0References1
NVD
NVD
added 2021/12/01 4:15 p.m.13 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

8.1CVSS0.00085EPSS
Exploits0References2
Prion
Prion
added 2021/12/01 4:15 p.m.9 views

Authentication flaw

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

4.8CVSS8AI score0.00085EPSS
Exploits0References2
CVE
CVE
added 2021/12/01 3:38 p.m.38 views

CVE-2020-10627

CVE-2020-10627 affects Insulet Omnipod Insulin Management System models with product IDs 19191 and 40160. The vulnerability stems from a wireless RF communication protocol between the insulin pump and the manufacturer’s Personal Diabetes Manager that does not properly implement authentication or ...

8.1CVSS8AI score0.00085EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2021/12/01 3:38 p.m.10 views

CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An...

7.3CVSS8.1AI score0.00085EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2021/12/01 12:0 a.m.3 views

PT-2021-9161 · Insulet · Insulet Omnipod Insulin Management System

Name of the Vulnerable Software and Affected Versions: Insulet Omnipod Insulin Management System versions with product ID 19191 and 40160 Description: The wireless RF communication protocol used by the Insulet Omnipod Insulin Management System does not properly implement authentication or...

8.1CVSS7.8AI score0.00085EPSS
Exploits0References4
Hacker One
Hacker One
added 2020/05/14 9:39 p.m.380 views

Insulet Corporation: Subdomain Takeover due to unclaimed domain pointing to Acquia Cloud

ssue Details The consultant identified that subdomain http:// or https://qa.myomnipod.com Web Site Not Found Sorry, we could not find any content for this web address. Please check the URL. If you are an Acquia Cloud customer and expect to see your site at this address, you'll need to add this...

0.4AI score
Exploits0
ICS
ICS
added 2020/03/19 12:0 a.m.46 views

Insulet Omnipod

1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low skill level to exploit/public exploits are known for this vulnerability Vendor: Insulet Equipment: Omnipod Insulin Management System Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an...

8.1CVSS8AI score0.00085EPSS