900 matches found
CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...
EUVD-2019-20154
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
EUVD-2019-20153
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...
Dräger Infinity Acute Care System和Dräger Standalone Infinity M540 patient monitor 数据伪造问题漏洞
The Dräger Infinity Acute Care System and the Dräger Standalone Infinity M540 patient monitor are both products of the German company Dräger. The Dräger Infinity Acute Care System is an emergency monitoring platform that integrates patient monitoring, clinical workstations, and medical informatio...
PT-2026-45862
Name of the Vulnerable Software and Affected Versions Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions prior to VG4.2 Description A network message handling issue allows remote attackers to inject spoofed or tampered data. This can lead to denial-of-service...
Dräger Infinity Acute Care System和Dräger Standalone Infinity M540 patient monitor 安全漏洞
The Dräger Infinity Acute Care System and the Dräger Standalone Infinity M540 patient monitor are both products of the German company Dräger. The Dräger Infinity Acute Care System is an emergency monitoring platform that integrates patient monitoring, clinical workstations, and medical informatio...
PT-2026-45864
Name of the Vulnerable Software and Affected Versions Dräger Zeus Infinity Empowered Zeus IE affected versions not specified Dräger Zeus RS C500 affected versions not specified Description A local security issue exists in anesthesia workstations that allows unauthorized individuals with physical...
PT-2026-45813
Name of the Vulnerable Software and Affected Versions Dräger Infinity M300 versions VG2.x and earlier Description A network-based denial of service issue exists that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots. This can lead to the device...
PT-2026-45739
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
Dräger多款产品 安全漏洞
Dräger Infinity Delta, among others, are products of the German company Dräger. The Dräger Infinity Delta is a multi-parameter clinical monitor. The Dräger Infinity Kappa is a multi-parameter patient monitor. The Dräger Infinity Delta XL is a high-performance multi-parameter patient monitor...
Dräger Infinity M300 资源管理错误漏洞
The Dräger Infinity M300 is a wearable telemetry patient monitoring device developed by the German company Dräger. Versions of the Dräger Infinity M300 prior to version 2.3.1 contained a resource management vulnerability. This vulnerability stemmed from a network-based denial-of-service issue,...
PT-2026-45810
Name of the Vulnerable Software and Affected Versions Dräger Infinity M300 versions prior to VG2.3.2 Description A network-based denial of service issue exists that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. This...
CVE-2019-25718
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2019-25716
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...
CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2019-25718
Affected product: Dräger Infinity Explorer C700. Vulnerability: privilege escalation allowing kiosk-mode escape to reach the underlying OS via a specific dialog interaction. Impact: attacker can break out of kiosk mode, gain OS control, and cause the Delta Family patient monitor display to show i...
CVE-2019-25718
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2019-25716
The CVE affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. A denial-of-service flaw lets an attacker send malformed network packets to reboot the device, disrupting monitoring until it reverts to default configuration and loses network connectivity. Documented metrics show CVSSv...
CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet
Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...