Lucene search
+L

1065 matches found

Positive Technologies
Positive Technologies
•added 2026/06/02 12:00 a.m.•39 views

PT-2026-45813

Name of the Vulnerable Software and Affected Versions Dräger Infinity M300 versions VG2.x and earlier Description A network-based denial of service issue exists that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots. This can lead to the device...

7.1CVSS5.4AI score0.00175EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/06/02 12:00 a.m.•1 views

CVE-2019-25724: Uncontrolled Resource Consumption

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.9AI score0.00175EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/06/02 12:00 a.m.•34 views

PT-2026-45810

Name of the Vulnerable Software and Affected Versions Dräger Infinity M300 versions prior to VG2.3.2 Description A network-based denial of service issue exists that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. This...

7.1CVSS5.5AI score0.00187EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/06/02 12:00 a.m.•0 views

CVE-2019-25717: Insertion of Sensitive Information into Externally-Accessible File or Directory

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS5.8AI score0.00203EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2026/06/02 12:00 a.m.•19 views

Dräger Infinity M300 资源管理错误漏洞

The Dräger Infinity M300 is a wearable telemetry patient monitoring device developed by the German company Dräger. Versions of the Dräger Infinity M300 prior to version 2.3.1 contained a resource management vulnerability. This vulnerability stemmed from a network-based denial-of-service issue,...

7.1CVSS5.4AI score0.00187EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/06/02 12:00 a.m.•39 views

PT-2026-45739

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00132EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2026/06/02 12:00 a.m.•21 views

Dräger多款产品 安全漏洞

Dräger Infinity Delta, among others, are products of the German company Dräger. The Dräger Infinity Delta is a multi-parameter clinical monitor. The Dräger Infinity Kappa is a multi-parameter patient monitor. The Dräger Infinity Delta XL is a high-performance multi-parameter patient monitor...

5.3CVSS5.5AI score0.00203EPSS
SaveExploits0References2
NVD
NVD
•added 2026/06/01 11:16 p.m.•23 views

CVE-2019-25718

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...

8.6CVSS0.00118EPSS
SaveExploits0References2
NVD
NVD
•added 2026/06/01 10:16 p.m.•26 views

CVE-2019-25716

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.5CVSS0.00413EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
•added 2026/06/01 9:41 p.m.•16 views

CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...

8.6CVSS5.9AI score0.00118EPSS
SaveExploits0References2
CVE
CVE
•added 2026/06/01 9:41 p.m.•38 views

CVE-2019-25718

Affected product: Dräger Infinity Explorer C700. Vulnerability: privilege escalation allowing kiosk-mode escape to reach the underlying OS via a specific dialog interaction. Impact: attacker can break out of kiosk mode, gain OS control, and cause the Delta Family patient monitor display to show i...

8.6CVSS5.9AI score0.00118EPSS
SaveExploits0References2Affected Software1
attackerkb
attackerkb
•added 2026/06/01 9:41 p.m.•10 views

CVE-2019-25718

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...

8.6CVSS5.8AI score0.00118EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2026/06/01 9:41 p.m.•47 views

CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...

8.6CVSS0.00118EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2026/06/01 9:15 p.m.•53 views

CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.00413EPSS
SaveExploits0References2
CVE
CVE
•added 2026/06/01 9:15 p.m.•47 views

CVE-2019-25716

The CVE affects Dräger Infinity Delta, Delta XL, and Kappa patient monitors. A denial-of-service flaw lets an attacker send malformed network packets to reboot the device, disrupting monitoring until it reverts to default configuration and loses network connectivity. Documented metrics show CVSSv...

7.5CVSS5.9AI score0.00413EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/06/01 12:00 a.m.•1 views

CVE-2019-25716: External Control of System or Configuration Setting

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.5CVSS5.9AI score0.00413EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2026/06/01 12:00 a.m.•22 views

Dräger多款产品 安全漏洞

Dräger Infinity Delta, among others, are products of the German company Dräger. The Dräger Infinity Delta is a multi-parameter clinical monitor. The Dräger Infinity Kappa is a multi-parameter patient monitor. The Dräger Infinity Delta XL is a high-performance multi-parameter patient monitor...

7.5CVSS5.5AI score0.00413EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/06/01 12:00 a.m.•4 views

CVE-2019-25718: User Interface (UI) Misrepresentation of Critical Information

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...

8.6CVSS5.9AI score0.00118EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2026/06/01 12:00 a.m.•21 views

Dräger Infinity Explorer C700 安全漏洞

The Dräger Infinity Explorer C700 is an integrated medical-grade monitoring workstation component developed by the German company Dräger. The Dräger Infinity Explorer C700 has a security vulnerability that stems from privilege escalation. This vulnerability could allow attackers to break through...

8.6CVSS5.3AI score0.00118EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2026/05/12 12:00 a.m.•27 views

PT-2026-40387

Missing lock bit protection for NBIO registers could allow a local admin-privileged attacker to modify MMIO routing configurations, potentially resulting in loss of SEV-SNP guest integrity...

5.9CVSS5.8AI score0.00116EPSS
SaveExploits0References2
Rows per page