500 matches found
Haas Automation Controller 安全漏洞
Haas Automation Controller is an industrial control system from Haas Automation, USA. A security vulnerability exists in Haas Automation Controller version 100.20.000.1110, which stems from the fact that communication traffic for the Ethernet Q Command Service is transmitted in clear text, which...
Securing IoT devices against attacks that target critical infrastructure
South Staffordshire PLC, a company that supplies water to over one million customers in the United Kingdom, notified its customers in August of being a target of a criminal cyberattack. This incident highlights the sophisticated threats that critical industries face today. According to South...
Securing IoT devices against attacks that target critical infrastructure
South Staffordshire PLC, a company that supplies water to over one million customers in the United Kingdom, notified its customers in August of being a target of a criminal cyberattack. This incident highlights the sophisticated threats that critical industries face today. According to South...
Control System Defense: Know the Opponent
Summary Traditional approaches to securing OT/ICS do not adequately address current threats. Operational technology/industrial control system OT/ICS assets that operate, control, and monitor day-to-day critical infrastructure and industrial processes continue to be an attractive target for...
The vulnerability of the SCADA system AVEVA Edge’s script creation function, related to insufficient warning for dangerous actions, allows a violator to execute arbitrary code.
The vulnerability of the SCADA system AVEVA Edge’s script creation function is related to insufficient warnings about dangerous actions. Exploiting this vulnerability allows a perpetrator to execute arbitrary codes...
The vulnerability of the mySCADA myPRO system for visualizing and controlling industrial processes, related to the lack of measures for cleaning input data, allows a intruder to execute arbitrary commands.
The vulnerability of the mySCADA myPRO industrial process visualization and control system is related to the lack of measures for cleaning incoming data. Exploiting this vulnerability allows a remote attacker to execute arbitrary commands...
CVE-2022-30791
creationtimestamp| type| source ---|---|--- 2022-07-11 14:19:09+00:00| seen| https://t.me/cibsecurity/45899 2026-03-17 12:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-01...
Baker Hughes Bently Nevada 3701/40 访问控制错误漏洞
The Baker Hughes Bently Nevada 3701/40 is a Condition Detection System from Baker Hughes USA. An Access Control Error vulnerability exists in the Bently Nevada 3701/4X Series and 60M100 3701/60 versions, which stems from affected products having hard-coded Maintenance Interface credentials in the...
CVE-2022-32081
creationtimestamp| type| source ---|---|--- 2022-07-02 00:40:04+00:00| seen| https://t.me/cibsecurity/45534 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...
CVE-2022-31806
creationtimestamp| type| source ---|---|--- 2022-06-29 02:51:42+00:00| published-proof-of-concept| https://t.me/CyberSecurityTechnologies/6291 2022-12-01 09:11:42+00:00| seen| https://t.me/truesecator/3768 2022-12-01 20:15:38+00:00| seen| https://t.me/icscert/664 2025-11-25 11:00:00+00:00| seen|...
The vulnerability of the Data Server database in the interactive graphical SCADA system allows a intruder to gain access to read, modify, or delete files.
The vulnerability of the Data Server database in the Interactive Graphical SCADA System IGSS is related to the absence of authentication procedures. Exploiting this vulnerability could allow a malicious actor to gain access to read, modify, or delete files by sending specially crafted messages...
The vulnerability of the Data Server database in the interactive graphical SCADA system, allowing a intruder to execute arbitrary code.
The vulnerability of the Data Server database in the Interactive Graphical SCADA System IGSS involves copying buffers without checking the size of the input data. Exploiting this vulnerability allows a malicious actor to execute arbitrary code by sending specially crafted messages...
Trellix Threat Labs Uncovers Critical Flaws in Widely Used Building Access Control System
Trellix Threat Labs Uncovers Critical Flaws in Widely Used Building Access Control System By Trellix · June 9, 2022 This story was also written by Steve Povolny and Sam Quinn. Today at the Hardwear.io Security Trainings and Conference, Trellix Threat Labs is sharing new research into...
The vulnerability of HID Mercury programmable logic controllers’ microprogramming software lies in the improper limitation of the path name to the restricted access directory. This allows a malicious actor to load any file into any directory of the file system.
The vulnerability of HID Mercury programmable logic controllers’ microprogramming software is related to an incorrect limitation on the path name to the restricted access directory. Exploiting this vulnerability allows a malicious actor to download any file into any directory of the file system b...
The vulnerability of the SCADA system “SKADA-NEV” is related to insufficient restrictions on authentication attempts, allowing a intruder to gain access to the user account.
The vulnerability of the SCADA system “SKADA-NEV” is related to insufficient restrictions on authentication attempts. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain access to the user account by force...
Horner Automation Cscape Csfont Buffer Overflow Vulnerability
Horner Automation Cscape is a set of programming software for industrial control system development from Horner Automation, Inc. A buffer overflow vulnerability exists in Horner Automation Cscape Csfont, which can be exploited by attackers to execute arbitrary code...
Horner Automation Cscape Csfont Out-of-Bounds Reading Vulnerability
Horner Automation Cscape is a programming software for industrial control system development from Horner Automation, Inc. An out-of-bounds read vulnerability exists in Horner Automation Cscape Csfont, which can be exploited by attackers to execute arbitrary code...
Horner Automation Cscape Csfont Out-of-Bounds Writing Vulnerability
Horner Automation Cscape is a programming software for industrial control system development from Horner Automation, Inc. An out-of-bounds write vulnerability exists in Horner Automation Cscape Csfont, which can be exploited by attackers to execute arbitrary code...
Horner Automation Cscape Csfont Out-of-Bounds Write Vulnerability (CNVD-2022-64133)
Horner Automation Cscape is a programming software for industrial control system development from Horner Automation, Inc. An out-of-bounds write vulnerability exists in Horner Automation Cscape Csfont, which can be exploited by attackers to execute arbitrary code...
The vulnerability of the server virtualization automation design (Automation Design) SCADA system Yokogawa CENTUM VP’s network protocol implementation allows a hacker to exploit the functions provided by the AD server.
The vulnerability of the server network protocol implementation in the Automation Design SCADA system of Yokogawa CENTUM VP is related to errors during the authentication process. Exploiting this vulnerability allows a malicious actor to utilize the features provided by the AD server...