1626 matches found
Siemens Patches Improper Access Vulnerability in Ruggedcom Protocol
Industrial manufacturer Siemens is encouraging users running devices that use its Ruggedcom Discovery Protocol RCDP to apply firmware updates this week. The updates resolve a serious and remotely exploitable vulnerability that could let an attacker carry out administrative actions. The issue, an...
LAquis SCADA 4.1.0.2385 Directory Traversal
require 'msf/core' class MetasploitModule 'LAquis SCADA Web Server Directory Traversal Information Disclosure', 'Description' = %q This module exploits a directory traversal vulnerability found in the LAquis SCADA application. The vulnerability is triggered when sending a series of dot dot slashe...
Threat Landscape for Industrial Automation Systems in H1 2017
Kaspersky Lab Industrial Control Systems Cyber Emergency Response Team Kaspersky Lab ICS CERT publishes the results of its research on the threat landscape for industrial automation systems for the first six months of 2017. All statistical data used in this report was collected using the Kaspersk...
LAquis SCADA 4.1.0.2385 - Directory Traversal Exploit
Exploit for multiple platform in category remote exploits require 'msf/core' class MetasploitModule 'LAquis SCADA Web Server Directory Traversal Information Disclosure', 'Description' = %q This module exploits a directory traversal vulnerability found in the LAquis SCADA application. The...
LAquis SCADA 4.1.0.2385 - Directory Traversal (Metasploit)
LAquis SCADA 4.1.0.2385 - Directory Traversal Metasploit require 'msf/core' class MetasploitModule 'LAquis SCADA Web Server Directory Traversal Information Disclosure', 'Description' = %q This module exploits a directory traversal vulnerability found in the LAquis SCADA application. The...
Saia Burgess Controls PCD Controllers
CVSS v3 5.3 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Saia Burgess Controls Equipment: PCD Controllers Vulnerability: Information Exposure REPOSTED INFORMATION This advisory was originally posted to the NCCIC Portal on August 22, 2017, and is being released to the...
Digium Asterisk GUI
CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Digium Equipment: Asterisk GUI Vulnerability: Improper Neutralization of Special Elements used in an OS Command AFFECTED PRODUCTS The following versions of Asterisk GUI, a framework for configuring graphical user...
Infinite Automation Mango Automation Command Injection
require 'msf/core' class MetasploitModule 'Infinite Automation Mango Automation Command Injection', 'Description' = %q This module exploits a command injection vulnerability found in Infinite Automation Systems Mango Automation v2.5.0 - 2.6.0 beta builds prior to 430. , 'Author' = 'james fitts' ,...
Fatek Automation PLC WinProladder 3.11 Build 14701 Buffer Overflow
require 'msf/core' class MetasploitModule 'Fatek Automation PLC WinProladder Stack-based Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in Fatek Automation PLC WinProladder v3.11 Build 14701. The vulnerability is triggered when a client connects to a...
KingScada AlarmServer 3.1.2.13 - Remote Stack Buffer Overflow (Metasploit)
require 'msf/core' class MetasploitModule 'KingScada AlarmServer Stack Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in KingScada 'James Fitts' , 'License' = MSFLICENSE, 'References' = 'CVE', '2014-0787' , 'ZDI', '14-071' , 'URL',...
LOYTEC LVIS-3ME
CVSS v3 8.1 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: LOYTEC Equipment: LVIS-3ME Vulnerabilities: Relative Path Traversal, Insufficient Entropy, Cross-site Scripting, Insufficiently Protected Credentials AFFECTED PRODUCTS The following versions of LVIS-3ME, an HMI Touch...
Multiple flaws found in smart syringe pump
A syringe pump is a small infusion pump that delivers liquids, either medication or nutrients, in small quantities into the patient's system. Hospitals, nursing homes, and homes with residents under acute or palliative care use them. Accurate and safe delivery of dosage from a variety of syringes...
Viap Automation WinPLC7 5.0.45.5921 - Recv Buffer Overflow (Metasploit)
require 'msf/core' class MetasploitModule 'VIPA Authomation WinPLC7 recv Stack Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in VIPA Automation WinPLC7 'james fitts' , 'License' = MSFLICENSE, 'References' = 'ZDI', '17-112' , 'CVE', '2017-5177' ,...
Fatek Automation PLC WinProladder 3.11 Build 14701 - Stack Buffer Overflow (Metasploit)
require 'msf/core' class MetasploitModule 'Fatek Automation PLC WinProladder Stack-based Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in Fatek Automation PLC WinProladder v3.11 Build 14701. The vulnerability is triggered when a client connects to a...
Viap Automation WinPLC7 5.0.45.5921 - Recv Buffer Overflow Exploit
Exploit for windows platform in category remote exploits require 'msf/core' class MetasploitModule 'VIPA Authomation WinPLC7 recv Stack Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in VIPA Automation WinPLC7 'james fitts' , 'License' = MSFLICENSE,...
Hackers Can Remotely Access Syringe Infusion Pumps to Deliver Fatal Overdoses
Internet-of-things are turning every industry into the computer industry, making customers think that their lives would be much easier with smart devices. However, such devices could potentially be compromised by hackers. There are, of course, some really good reasons to connect certain devices t...
i-SENS, Inc. SmartLog Diabetes Management Software
OVERVIEW Independent researcher Mark Cross has identified an uncontrolled search path element vulnerability in i-SENS, Inc. SmartLog Diabetes Management Software. i-SENS has produced an update that mitigates this vulnerability. Mark Cross has tested the update to validate that it resolves the...
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)
OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSMA-17-250-02 Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities that was published September 7, 2017, on the NCCIC/ICS-CERT web site. Independent researcher Scott Gayou has identified eight...
PHOENIX CONTACT, Innominate Security Technologies mGuard Firmware
CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: PHOENIX CONTACT, Innominate Security Technologies Equipment: mGuard firmware Vulnerability: Null Pointer Dereference AFFECTED PRODUCTS The following versions of mGuard firmware versions 8.0.0 to 8.5.1, running on thes...
ICSSPLOIT: A Industrial Control System Exploitation Framework
PenTestIT RSS Feed This framework is based on RouterSploit, which has already been covered on this blog. Infact, that's how I got to know about it - I was checking the source for updates and I found a reference for this Industrial Control System ICS exploitation framework - ICSSPLOIT. ICS securit...