Securelist
Securelist
added 2017/09/28 12:0 p.m.18 views

Threat Landscape for Industrial Automation Systems in H1 2017

Kaspersky Lab Industrial Control Systems Cyber Emergency Response Team Kaspersky Lab ICS CERT publishes the results of its research on the threat landscape for industrial automation systems for the first six months of 2017. All statistical data used in this report was collected using the Kaspersk...

6.8AI score
SaveExploits0
0day.today
0day.today
added 2017/09/28 12:0 a.m.86 views

LAquis SCADA 4.1.0.2385 - Directory Traversal Exploit

Exploit for multiple platform in category remote exploits require 'msf/core' class MetasploitModule 'LAquis SCADA Web Server Directory Traversal Information Disclosure', 'Description' = %q This module exploits a directory traversal vulnerability found in the LAquis SCADA application. The...

5.8AI score0.08733EPSS
SaveExploits4
exploitpack
exploitpack
added 2017/09/27 12:0 a.m.31 views

LAquis SCADA 4.1.0.2385 - Directory Traversal (Metasploit)

LAquis SCADA 4.1.0.2385 - Directory Traversal Metasploit require 'msf/core' class MetasploitModule 'LAquis SCADA Web Server Directory Traversal Information Disclosure', 'Description' = %q This module exploits a directory traversal vulnerability found in the LAquis SCADA application. The...

0.2AI score0.08733EPSS
SaveExploits4
ICS
ICS
added 2017/09/21 12:0 a.m.44 views

Digium Asterisk GUI

CVSS v3 8.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Digium Equipment: Asterisk GUI Vulnerability: Improper Neutralization of Special Elements used in an OS Command AFFECTED PRODUCTS The following versions of Asterisk GUI, a framework for configuring graphical user...

9CVSS9.1AI score0.06447EPSS
SaveExploits0References3
ICS
ICS
added 2017/09/21 12:0 a.m.44 views

Saia Burgess Controls PCD Controllers

CVSS v3 5.3 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Saia Burgess Controls Equipment: PCD Controllers Vulnerability: Information Exposure REPOSTED INFORMATION This advisory was originally posted to the NCCIC Portal on August 22, 2017, and is being released to the...

5.3CVSS5.5AI score0.01233EPSS
SaveExploits0References2
Packet Storm
Packet Storm
added 2017/09/15 12:0 a.m.101 views

Infinite Automation Mango Automation Command Injection

require 'msf/core' class MetasploitModule 'Infinite Automation Mango Automation Command Injection', 'Description' = %q This module exploits a command injection vulnerability found in Infinite Automation Systems Mango Automation v2.5.0 - 2.6.0 beta builds prior to 430. , 'Author' = 'james fitts' ,...

6.5CVSS0.1AI score0.03257EPSS
SaveExploits5
Exploit DB
Exploit DB
added 2017/09/14 12:0 a.m.50 views

KingScada AlarmServer 3.1.2.13 - Remote Stack Buffer Overflow (Metasploit)

require 'msf/core' class MetasploitModule 'KingScada AlarmServer Stack Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in KingScada 'James Fitts' , 'License' = MSFLICENSE, 'References' = 'CVE', '2014-0787' , 'ZDI', '14-071' , 'URL',...

10CVSS5.2AI score0.1602EPSS
SaveExploits5
Packet Storm
Packet Storm
added 2017/09/14 12:0 a.m.57 views

Fatek Automation PLC WinProladder 3.11 Build 14701 Buffer Overflow

require 'msf/core' class MetasploitModule 'Fatek Automation PLC WinProladder Stack-based Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in Fatek Automation PLC WinProladder v3.11 Build 14701. The vulnerability is triggered when a client connects to a...

6CVSS0.9AI score0.08906EPSS
SaveExploits4
ICS
ICS
added 2017/09/14 12:0 a.m.76 views

LOYTEC LVIS-3ME

CVSS v3 8.1 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: LOYTEC Equipment: LVIS-3ME Vulnerabilities: Relative Path Traversal, Insufficient Entropy, Cross-site Scripting, Insufficiently Protected Credentials AFFECTED PRODUCTS The following versions of LVIS-3ME, an HMI Touch...

8.8CVSS8.5AI score0.0351EPSS
SaveExploits0References3
Malwarebytes
Malwarebytes
added 2017/09/13 4:27 p.m.19 views

Multiple flaws found in smart syringe pump

A syringe pump is a small infusion pump that delivers liquids, either medication or nutrients, in small quantities into the patient's system. Hospitals, nursing homes, and homes with residents under acute or palliative care use them. Accurate and safe delivery of dosage from a variety of syringes...

7.5AI score
SaveExploits0
Exploit DB
Exploit DB
added 2017/09/13 12:0 a.m.64 views

Fatek Automation PLC WinProladder 3.11 Build 14701 - Stack Buffer Overflow (Metasploit)

require 'msf/core' class MetasploitModule 'Fatek Automation PLC WinProladder Stack-based Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in Fatek Automation PLC WinProladder v3.11 Build 14701. The vulnerability is triggered when a client connects to a...

8CVSS7.7AI score0.08906EPSS
SaveExploits4
0day.today
0day.today
added 2017/09/13 12:0 a.m.59 views

Viap Automation WinPLC7 5.0.45.5921 - Recv Buffer Overflow Exploit

Exploit for windows platform in category remote exploits require 'msf/core' class MetasploitModule 'VIPA Authomation WinPLC7 recv Stack Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in VIPA Automation WinPLC7 'james fitts' , 'License' = MSFLICENSE,...

5CVSS7.5AI score0.17711EPSS
SaveExploits5
Exploit DB
Exploit DB
added 2017/09/13 12:0 a.m.65 views

Viap Automation WinPLC7 5.0.45.5921 - Recv Buffer Overflow (Metasploit)

require 'msf/core' class MetasploitModule 'VIPA Authomation WinPLC7 recv Stack Buffer Overflow', 'Description' = %q This module exploits a stack based buffer overflow found in VIPA Automation WinPLC7 'james fitts' , 'License' = MSFLICENSE, 'References' = 'ZDI', '17-112' , 'CVE', '2017-5177' ,...

7.5CVSS7.2AI score0.17711EPSS
SaveExploits5
The Hacker News
The Hacker News
added 2017/09/09 2:50 a.m.151 views

Hackers Can Remotely Access Syringe Infusion Pumps to Deliver Fatal Overdoses

Internet-of-things are turning every industry into the computer industry, making customers think that their lives would be much easier with smart devices. However, such devices could potentially be compromised by hackers. There are, of course, some really good reasons to connect certain devices t...

8.4AI score0.13021EPSS
SaveExploits4
ICS
ICS
added 2017/09/07 12:0 a.m.33 views

i-SENS, Inc. SmartLog Diabetes Management Software

OVERVIEW Independent researcher Mark Cross has identified an uncontrolled search path element vulnerability in i-SENS, Inc. SmartLog Diabetes Management Software. i-SENS has produced an update that mitigates this vulnerability. Mark Cross has tested the update to validate that it resolves the...

9.3CVSS7.8AI score0.01761EPSS
SaveExploits0References3
ICS
ICS
added 2017/09/07 12:0 a.m.53 views

PHOENIX CONTACT, Innominate Security Technologies mGuard Firmware

CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: PHOENIX CONTACT, Innominate Security Technologies Equipment: mGuard firmware Vulnerability: Null Pointer Dereference AFFECTED PRODUCTS The following versions of mGuard firmware versions 8.0.0 to 8.5.1, running on thes...

5CVSS6.8AI score0.02664EPSS
SaveExploits1References3
ICS
ICS
added 2017/09/07 12:0 a.m.129 views

Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSMA-17-250-02 Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities that was published September 7, 2017, on the NCCIC/ICS-CERT web site. Independent researcher Scott Gayou has identified eight...

8.1CVSS8.1AI score0.13021EPSS
SaveExploits4References2
pentestit
pentestit
added 2017/09/03 12:56 a.m.1256 views

ICSSPLOIT: A Industrial Control System Exploitation Framework

PenTestIT RSS Feed This framework is based on RouterSploit, which has already been covered on this blog. Infact, that's how I got to know about it - I was checking the source for updates and I found a reference for this Industrial Control System ICS exploitation framework - ICSSPLOIT. ICS securit...

9.3CVSS8.5AI score0.0591EPSS
SaveExploits1
ICS
ICS
added 2017/08/31 12:0 a.m.35 views

Moxa SoftCMS Live Viewer

CVSS v3 9.8 AFFECTED PRODUCTS The following versions of SoftCMS Live Viewer, a video surveillance software designed for industrial automation systems, are affected: SoftCMS Live Viewer, Version 1.6 and prior versions. IMPACT Successful exploitation of this vulnerability could allow an...

9.8CVSS10AI score0.01169EPSS
SaveExploits0References3
ICS
ICS
added 2017/08/31 12:0 a.m.39 views

Siemens 7KM PAC Switched Ethernet

CVSS v3 4.3 ATTENTION: Low skill level to exploit. Vendor: Siemens Equipment: 7KM PAC Switched Ethernet Vulnerability: Resource Exhaustion AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following 7KM PAC Switched Ethernet PROFINET expansion modules: 7KM PAC Switched Ethernet...

6.5CVSS6.5AI score0.00537EPSS
SaveExploits0References3