Lucene search
+L

2237 matches found

Prion
Prion
added 2013/04/04 11:58 a.m.19 views

Default credentials

The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data...

10CVSS7.6AI score0.02105EPSS
SaveExploits0References1
CVE
CVE
added 2013/04/04 10:00 a.m.52 views

CVE-2013-2762

The CVE-2013-2762 issue affects the Schneider Electric Magelis XBT HMI controller and is caused by a default password used for authentication of configuration uploads. This allows remote attackers to bypass access restrictions via crafted configuration data. Exploitation details or existence of i...

10CVSS7.3AI score0.02105EPSS
SaveExploits0References1Affected Software1
ICS
ICS
added 2013/03/22 6:00 a.m.61 views

GE Proficy HMI/SCADA CIMPLICITY WebView Improper Input Validation

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on June 19, 2013, and is now being released to the ICS-CERT-Web page. Independent researchers ZombiE and amisto0x07 have identified an improper input validation vulnerability in the GE CIMPLICITY WebView application...

9.3CVSS7.5AI score0.03769EPSS
SaveExploits0References10
ThreatPost
ThreatPost
added 2013/03/21 6:57 p.m.14 views

DHS, ICS-CERT Warn of Siemens HMI Vulnerabilities

The Department of Homeland Security and the ICS-CERT issued an advisory yesterday warning of serious vulnerabilities in Siemens industrial control software deployed in a number of industries including water, gas and oil, and chemical. Siemens said it has patched the flaws in a new version of its...

0.2AI score
SaveExploits0References2
NVD
NVD
added 2013/03/21 2:55 p.m.29 views

CVE-2013-0671

Directory traversal vulnerability in Siemens WinCC TIA Portal 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL...

4CVSS6.2AI score0.02328EPSS
SaveExploits0References2
NVD
NVD
added 2013/03/21 2:55 p.m.23 views

CVE-2013-0668

Multiple cross-site scripting XSS vulnerabilities in the HMI web application in Siemens WinCC TIA Portal 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL...

4.3CVSS5.6AI score0.01513EPSS
SaveExploits0References2
NVD
NVD
added 2013/03/21 2:55 p.m.25 views

CVE-2011-4515

Siemens WinCC TIA Portal 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging 1 physical access or 2 Sm@rt Server access...

4.6CVSS5.6AI score0.00381EPSS
SaveExploits0References2
Prion
Prion
added 2013/03/21 2:55 p.m.21 views

Crlf injection

CRLF injection vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL...

4.3CVSS7.3AI score0.01539EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/03/21 2:55 p.m.25 views

Directory traversal

Directory traversal vulnerability in Siemens WinCC TIA Portal 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL...

4CVSS6.7AI score0.02328EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/03/21 2:55 p.m.19 views

Cross site scripting

Multiple cross-site scripting XSS vulnerabilities in the HMI web application in Siemens WinCC TIA Portal 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL...

4.3CVSS5.9AI score0.01513EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/03/21 2:55 p.m.19 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...

4.3CVSS6AI score0.01513EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/03/21 2:55 p.m.17 views

Design/Logic Flaw

Siemens WinCC TIA Portal 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging 1 physical access or 2 Sm@rt Server access...

4.6CVSS6.1AI score0.00381EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/03/21 2:55 p.m.22 views

Cross site request forgery (csrf)

The HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to cause a denial of service daemon crash via a crafted HTTP request...

4CVSS6.5AI score0.0183EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2013/03/21 2:55 p.m.21 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data...

3.5CVSS5.6AI score0.01196EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2013/03/21 2:00 p.m.66 views

CVE-2013-0669

Siemens WinCC (TIA Portal) V11 HMI web application is affected by CVE-2013-0669. An authenticated user can craft HTTP requests that crash the HMI Web application, causing a denial of service. The root cause is Improper Input Validation in the Web server, with network attack vector and no confiden...

4CVSS6.3AI score0.0183EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2013/03/21 2:00 p.m.58 views

CVE-2011-4515

Summary of CVE-2011-4515 (Siemens WinCC TIA Portal): The vulnerability affects Siemens WinCC (TIA Portal) HMI Web server in version 11. It involves storing HMI Web-application passwords using a reversible scheme, leaving password data world-readable/writable and retrievable with local access or v...

4.6CVSS5.8AI score0.00381EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2013/03/21 2:00 p.m.59 views

CVE-2013-0671

CVE-2013-0671 affects Siemens WinCC (TIA Portal) 11. The vulnerability is a Directory Traversal vulnerability in the HMI Web server, exploitable by manipulating the URL to read panel server-side source code and user-defined scripts. It requires authenticated access; exploitation is not remote wit...

4CVSS6.4AI score0.02328EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2013/03/21 2:00 p.m.47 views

CVE-2013-0667

Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...

5.5AI score0.01513EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2013/03/21 2:00 p.m.36 views

CVE-2013-0669

The HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to cause a denial of service daemon crash via a crafted HTTP request...

6.1AI score0.0183EPSS
SaveExploits0References2
Check Point Advisories
Check Point Advisories
added 2013/03/21 12:00 a.m.45 views

SCADA DaqFactory HMI NETB Request Overflow (CVE-2011-3492)

Stack-based buffer overflow has been reported in Azeotech DAQFactory. The vulnerability is due to insufficient validation of incoming NETB requests to UDP port 20034. A remote attacker could exploit this vulnerability by sending a malicious request to the affected service. Successful exploitation...

10CVSS7.3AI score0.70909EPSS
SaveExploits5
Rows per page
Query Builder