Default credentials
The Schneider Electric Magelis XBT HMI controller has a default password for authentication of configuration uploads, which makes it easier for remote attackers to bypass intended access restrictions via crafted configuration data...
CVE-2013-2762
The CVE-2013-2762 issue affects the Schneider Electric Magelis XBT HMI controller and is caused by a default password used for authentication of configuration uploads. This allows remote attackers to bypass access restrictions via crafted configuration data. Exploitation details or existence of i...
GE Proficy HMI/SCADA CIMPLICITY WebView Improper Input Validation
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on June 19, 2013, and is now being released to the ICS-CERT-Web page. Independent researchers ZombiE and amisto0x07 have identified an improper input validation vulnerability in the GE CIMPLICITY WebView application...
DHS, ICS-CERT Warn of Siemens HMI Vulnerabilities
The Department of Homeland Security and the ICS-CERT issued an advisory yesterday warning of serious vulnerabilities in Siemens industrial control software deployed in a number of industries including water, gas and oil, and chemical. Siemens said it has patched the flaws in a new version of its...
CVE-2013-0671
Directory traversal vulnerability in Siemens WinCC TIA Portal 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL...
CVE-2013-0668
Multiple cross-site scripting XSS vulnerabilities in the HMI web application in Siemens WinCC TIA Portal 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL...
CVE-2011-4515
Siemens WinCC TIA Portal 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging 1 physical access or 2 Sm@rt Server access...
Crlf injection
CRLF injection vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL...
Directory traversal
Directory traversal vulnerability in Siemens WinCC TIA Portal 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL...
Cross site scripting
Multiple cross-site scripting XSS vulnerabilities in the HMI web application in Siemens WinCC TIA Portal 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL...
Cross site scripting
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...
Design/Logic Flaw
Siemens WinCC TIA Portal 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging 1 physical access or 2 Sm@rt Server access...
Cross site request forgery (csrf)
The HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to cause a denial of service daemon crash via a crafted HTTP request...
Cross site scripting
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data...
CVE-2013-0669
Siemens WinCC (TIA Portal) V11 HMI web application is affected by CVE-2013-0669. An authenticated user can craft HTTP requests that crash the HMI Web application, causing a denial of service. The root cause is Improper Input Validation in the Web server, with network attack vector and no confiden...
CVE-2011-4515
Summary of CVE-2011-4515 (Siemens WinCC TIA Portal): The vulnerability affects Siemens WinCC (TIA Portal) HMI Web server in version 11. It involves storing HMI Web-application passwords using a reversible scheme, leaving password data world-readable/writable and retrievable with local access or v...
CVE-2013-0671
CVE-2013-0671 affects Siemens WinCC (TIA Portal) 11. The vulnerability is a Directory Traversal vulnerability in the HMI Web server, exploitable by manipulating the URL to read panel server-side source code and user-defined scripts. It requires authenticated access; exploitation is not remote wit...
CVE-2013-0667
Cross-site scripting XSS vulnerability in the HMI web application in Siemens WinCC TIA Portal 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL...
CVE-2013-0669
The HMI web application in Siemens WinCC TIA Portal 11 allows remote authenticated users to cause a denial of service daemon crash via a crafted HTTP request...
SCADA DaqFactory HMI NETB Request Overflow (CVE-2011-3492)
Stack-based buffer overflow has been reported in Azeotech DAQFactory. The vulnerability is due to insufficient validation of incoming NETB requests to UDP port 20034. A remote attacker could exploit this vulnerability by sending a malicious request to the affected service. Successful exploitation...