Lucene search
+L

2237 matches found

Cvelist
Cvelist
added 2011/04/05 3:00 p.m.31 views

CVE-2011-1564

Multiple integer overflows in the HMI application in DATAC RealFlex RealWin 2.1 Build 6.1.10.10 and earlier allow remote attackers to execute arbitrary code via crafted 1 OnFCMISCFCSMSGBROADCAST and 2 OnFCMISCFCSMSGSEND packets, which trigger a heap-based buffer overflow...

7.8AI score0.18626EPSS
SaveExploits2References7
Cvelist
Cvelist
added 2011/04/05 3:00 p.m.28 views

CVE-2011-1562

Ecava IntegraXor HMI before n 3.60 Build 4032 allows remote attackers to bypass authentication and execute arbitrary SQL statements via unspecified vectors related to a crafted POST request. NOTE: some sources have reported this issue as SQL injection, but this might not be accurate...

8AI score0.01734EPSS
SaveExploits0References8
Tenable Nessus
Tenable Nessus
added 2011/03/25 12:00 a.m.19 views

Movicon SCADA/HMI Software Detection

Binary data scadamoviconinstalled.nbin...

7.3AI score
SaveExploits0References1
exploitpack
exploitpack
added 2011/03/22 12:00 a.m.32 views

iconics genesis32 and genesis64 - Multiple Vulnerabilities

iconics genesis32 and genesis64 - Multiple Vulnerabilities Sources: http://aluigi.org/adv/genesis1-adv.txt http://aluigi.org/adv/genesis2-adv.txt http://aluigi.org/adv/genesis3-adv.txt http://aluigi.org/adv/genesis4-adv.txt http://aluigi.org/adv/genesis5-adv.txt...

0.7AI score
SaveExploits0
ICS
ICS
added 2011/03/19 6:00 a.m.52 views

Sunway Force Control

Overview ICS-CERT has received a report from Security researcher Dillon Beresford of NSS Labs concerning vulnerabililities affecting Sunway ForceControl and pNetPower SCADA/HMI applications. The reported vulnerabilities are heap-based buffer overflows that could result in a denial of service or t...

10CVSS8.9AI score0.17566EPSS
SaveExploits1References10
CERT
CERT
added 2011/02/03 12:00 a.m.24 views

Sielco Sistemi Winlog server stack overflow

Overview Sielco Sistemi Winlog TCP/IP server contains a stack overflow vulnerability Description According to Sielco Sistemi's website: "Winlog is a software package for SCADA/HMI applications with web support, OPC client and a wide library of communication drivers and protocols for most PLCs...

9.3CVSS7.4AI score0.40462EPSS
SaveExploits6References4
Packet Storm
Packet Storm
added 2011/01/10 12:00 a.m.56 views

KingView 6.53 SCADA HMI Heap Overflow

Exploit Title: KingView 6.53 SCADA HMI Heap Overflow PoC Date: 9/28/2010 Author: Dillon Beresford Software Link: http://download.kingview.com/software/kingview%20English%20Version/kingview6.53EN.rar Version: 6.53 English Tested on: Windows XP SP1 works on SP2 and SP3 will release new targets afte...

1.2AI score
SaveExploits0
zdt
zdt
added 2011/01/09 12:00 a.m.61 views

KingView 6.5.3 SCADA HMI Heap Overflow PoC

Exploit for windows platform in category remote exploits Author: Dillon Beresford Software Link: http://download.kingview.com/software/kingview%20English%20Version/kingview6.53EN.rar Version: 6.53 English Tested on: Windows XP SP1 works on SP2 and SP3 will release new targets after CERT advisory ...

7.1AI score
SaveExploits0
Exploit DB
Exploit DB
added 2011/01/09 12:00 a.m.75 views

KingView 6.5.3 - SCADA HMI Heap Overflow

Exploit Title: KingView 6.53 SCADA HMI Heap Overflow PoC Date: 9/28/2010 Author: Dillon Beresford Software Link: http://download.kingview.com/software/kingview%20English%20Version/kingview6.53EN.rar Version: 6.53 English Tested on: Windows XP SP1 works on SP2 and SP3 will release new targets afte...

10CVSS5.2AI score0.21315EPSS
SaveExploits3
CVE
CVE
added 2010/12/23 5:00 p.m.63 views

CVE-2010-4597

Ecava IntegraXor HMI is affected by CVE-2010-4597 due to a stack-based buffer overflow in the save method of igcomm.dll (IntegraXor.Project ActiveX) prior to version 3.5.3900.10. An attacker could remotely trigger arbitrary code execution by sending a long string in the second argument. ICS-CERT ...

10CVSS8.3AI score0.18823EPSS
SaveExploits2References7Affected Software1
CERT
CERT
added 2010/12/17 12:00 a.m.30 views

Ecava IntegraXor stack-based buffer overflow vulnerability

Overview Ecava IntegraXor contains a stack-based buffer overflow vulnerability in the Ecava IntegraXor Human-Machine Interface HMI product that could allow the execution of arbitrary code. Description According to Ecava's website: IntegraXor is a suite of tools used to create and run a web-based...

8.1AI score
SaveExploits0References1
CERT
CERT
added 2010/11/19 12:00 a.m.33 views

RealFlex RealWin HMI service buffer overflows

Overview RealFlex RealWin 1.06 HMI service 912/tcp contains two stack buffer overflow vulnerabilities. Description RealFlex RealWin is a SCADA server package for medium and small applications designed to control and monitor real-time applications. The RealWin application runs an HMI service on po...

10CVSS7.6AI score0.62988EPSS
SaveExploits14References6
securityvulns
securityvulns
added 2008/09/30 12:00 a.m.46 views

DATAC RealWin 2.0 SCADA Software - Remote PreaAuth Exploit

Hi --------------------------------- http://www.dataconline.com/software/realwin.php "RealWin is a SCADA server product which includes a FlexView HMI and runs on current Microsoft Windows platforms 2000 and XP. It can operate on a single PC or multiple PCs connected through a TCP/IP network. It...

1.5AI score
SaveExploits0
Prion
Prion
added 2008/01/29 2:00 a.m.25 views

Heap overflow

Heap-based buffer overflow in w32rtr.exe in GE Fanuc CIMPLICITY HMI SCADA system 7.0 before 7.0 SIM 9, and earlier versions before 6.1 SP6 Hot fix - 0107081625176106, allow remote attackers to execute arbitrary code via unknown vectors...

10CVSS8.7AI score0.07917EPSS
SaveExploits0References9Affected Software1
NVD
NVD
added 2008/01/29 2:00 a.m.22 views

CVE-2008-0176

Heap-based buffer overflow in w32rtr.exe in GE Fanuc CIMPLICITY HMI SCADA system 7.0 before 7.0 SIM 9, and earlier versions before 6.1 SP6 Hot fix - 0107081625176106, allow remote attackers to execute arbitrary code via unknown vectors...

10CVSS8AI score0.07917EPSS
SaveExploits0References9
CVE
CVE
added 2008/01/29 1:00 a.m.59 views

CVE-2008-0176

GE Fanuc CIMPLICITY HMI contains a heap-based buffer overflow in w32rtr.exe that can be exploited remotely (network port 32000/tcp) to execute arbitrary code. Affected: CIMPLICITY HMI 6.1 (including SP6 hotfix 010708_162517_6106) and CIMPLICITY 7.0 up to SIM 9; older versions may also be vulnerab...

10CVSS8AI score0.07917EPSS
SaveExploits0References9Affected Software1
securityvulns
securityvulns
added 2008/01/27 12:00 a.m.65 views

C4 Security Advisory - GE Fanuc Cimplicity 6.1 Heap Overflow

Background ----------------- Vendor product information: CIMPLICITY is a powerful and technically advanced HMI/SCADA product. With its open system design approach, true client/server architecture, and the latest web technologies, CIMPLICITY allows you to realize the benefits of digitization for t...

10CVSS0.9AI score0.07917EPSS
SaveExploits0