2237 matches found
CVE-2016-5787
General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...
Design/Logic Flaw
General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...
CVE-2016-5787
CVE-2016-5787 affects GE Digital Proficy HMI/SCADA CIMPLICITY, prior to version 8.2 SIM 27. The root cause is improper handling of service DACLs, allowing a local user to modify the CIMPLICITY service configuration via unspecified vectors, enabling privilege elevation by tampering with the servic...
CVE-2016-5787
General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...
Scan Reveals Hydropower Plants, Other Critical Infrastructure Exposed Online
An Internet scan of the IPv4 address space uncovered more than 100 critical facilities exposed to the public Internet, including hydropower plants in Germany and Italy, and a smart building in Israel hosting luxury apartments. The investigation, conducted by researchers at Internet Wache of Berli...
WECON LeviStudio Stack Buffer Overflow Vulnerability
WECON LeviStudio is HMI programming software. WECON LeviStudio handles a stack buffer overflow vulnerability in certain files that could allow an attacker to cause a stack buffer overflow and execute arbitrary code in the context of the current process...
GE Proficy HMI/SCADA CIMPLICITY 8.2 local mention the right vulnerability
No description provided by source...
GE Proficy HMI/SCADA CIMPLICITY 8.2 - Privilege Escalation
Exploit for windows platform in category local exploits / Exploit Title: GE Proficy HMI/SCADA CIMPLICITY 8.2 Local Privilege Escalation Exploit0 day Vulnerability Discovery and Exploit Author: Zhou Yu Email: Version: 8.2 Tested on: Windows 7 SP1 X32 CVE : None Vulnerability Description:...
Rexroth Bosch BLADEcontrol-WebVIS SQL Injection Vulnerability
Rexroth Bosch BLADEcontrol is a web-based HMI system. Rexroth Bosch BLADEcontrol has a SQL injection vulnerability in database operations that could lead to control of the database server or remote code execution...
Advantech Patches WebAccess Remote Code Execution Flaws
Advantech has published a new version of its WebAccess product to address vulnerabilities that put installations at risk to remote code execution attacks. Exploiting the vulnerabilities would be a challenge, however, according to an advisory published Tuesday by the Industrial Control Systems Cyb...
Schneider Electric HMI Denial Of Service Tool
Schneider Electric HMI DoS Tool is a denial-of-service attack tool associated with malicious activity. The tool crafts and sends multiple HTTP requests that can potentially cause attacked systems to become temporarily unresponsive...
Schneider Electric Magelis HMI Advanced Panel Remote Denial Of Service (CVE-2016-8367; CVE-2016-8374)
A denial of service vulnerability exists in Schneider Electric Magelis HMI Advanced Panel, AKA Panelshock. The vulnerability is due to insufficient validation of incoming requests. A remote attacker can exploit this vulnerability by enticing an authenticated user to view crafted web content. This...
CVE-2016-2306
The HMI web server in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to obtain sensitive cleartext information by sniffing the network...
CVE-2016-2306
The HMI web server in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to obtain sensitive cleartext information by sniffing the network...
Code injection
The HMI web server in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to obtain sensitive cleartext information by sniffing the network...
CVE-2016-2306
CVE-2016-2306 affects Ecava IntegraXor HMI web server prior to version 5.0, build 4522. The root cause is cleartext transmission of sensitive information over the network, enabling remote attackers to sniff unencrypted data. The vulnerability has been confirmed in multiple sources and is associat...
CVE-2016-2306
The HMI web server in Ecava IntegraXor before 5.0 build 4522 allows remote attackers to obtain sensitive cleartext information by sniffing the network...
GE Proficy HMI SCADA CIMPLICITY Privilege Management Vulnerability
OVERVIEW Zhou Yu of Acorn Network Security identified an improper privilege management vulnerability and recently released exploit code for the GE Proficy HMI/SCADA CIMPLICITY application without coordination with ICS-CERT, the vendor, or any other coordinating entity known to ICS-CERT. GE produc...
WECON LeviStudio Buffer Overflow Vulnerabilities
OVERVIEW Independent security researchers Rocco Calvi and Brian Gorenc, working with Trend Micro’s Zero Day Initiative, have identified buffer overflow vulnerabilities in WECON’s LeviStudio software. WECON has not released a product fix to addresses the buffer overflow vulnerabilities in the...
Pro-face GP-Pro EX Denial of Service Vulnerability
Pro-face GP-Pro EX is a set of HMI screen editing and logic programming software from American Pro-face. A security vulnerability exists in Pro-face GP-Pro EX. A remote attacker could exploit this vulnerability to execute arbitrary code or cause a denial of service read across boundaries...