1749 matches found
CVE-2025-27254
CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass. The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify...
CVE-2025-27253
CVE-2025-27253 affects GE Vernova UR IED family devices (versions 7.0–8.60). The vulnerability is CWE-15: External Control of System or Configuration Setting, caused by improper input validation that allows an attacker to provide input which establishes a TCP connection via port forwarding. Lack ...
CVE-2025-27253
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to...
CVE-2025-27253
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to...
CVE-2025-27255: Use of Hard-coded Credentials
Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code...
PT-2025-10568
Name of the Vulnerable Software and Affected Versions GE Vernova UR IED family devices affected versions not specified Description The issue concerns an Insufficient Verification of Data Authenticity, which enables an authenticated user to install modified firmware. This is possible because...
CVE-2025-27257: Insufficient Verification of Data Authenticity
Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware. The firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration che...
PT-2025-10567
Name of the Vulnerable Software and Affected Versions GE Vernova Enervista UR Setup affected versions not specified Description The issue concerns a Missing Authentication for Critical Function vulnerability. It allows for Authentication Bypass due to a missing SSH server authentication, enabling...
PT-2025-10566
Name of the Vulnerable Software and Affected Versions GE Vernova EnerVista UR Setup affected versions not specified Description The issue concerns the use of hard-coded credentials in the software, allowing privilege escalation. An attacker can retrieve the hardcoded password by analyzing the...
PT-2025-10565
Name of the Vulnerable Software and Affected Versions GE Vernova EnerVista UR Setup affected versions not specified Description The issue concerns an improper authentication vulnerability that allows authentication bypass. It is possible to disable the software's startup authentication by modifyi...
CVE-2025-27254: Improper Ownership Management
CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass. The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify...
GE Vernova EnerVista UR 授权问题漏洞
GE Vernova EnerVista UR is a device configuration tool from GE Vernova USA that is compatible with all UR relay applications. An authorization issue vulnerability exists in the GE Vernova EnerVista UR that stems from improper authentication and could lead to authentication bypass...
CVE-2025-27256: Missing Authentication for Critical Function
Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network...
CVE-2025-27253: External Control of System or Configuration Setting
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to...
PT-2025-10564
Name of the Vulnerable Software and Affected Versions GE Vernova UR IED family devices versions 7.0 through 8.60 Description The issue is related to improper input validation, which allows an attacker to establish a TCP connection through port forwarding. This lack of validation for IP addresses...
technoboom.ge Cross Site Scripting vulnerability OBB-4034477
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
CVE-2020-25197
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system...
CVE-2020-36549
A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed...