CVE-2013-0651
The Portal installation process in GE Intelligent Platforms Proficy Real-Time Information Portal stores sensitive information under the web root with insufficient access control, which allows remote attackers to read configuration files, and discover data-source credentials, via a direct request...
CVE-2019-13559
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go int...
CVE-2011-1919
Multiple stack-based buffer overflows in GE Intelligent Platforms Proficy Applications before 4.4.1 SIM 101 and 5.x before 5.0 SIM 43 allow remote attackers to cause a denial of service daemon crash or possibly execute arbitrary code via crafted TCP message traffic to 1 PRProficyMgr.exe in Profic...
CVE-2019-13554
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service...
CVE-2019-10966
In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms...
CVE-2019-18267
An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site...
CVE-2019-13524
GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versionsEnd of Life may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service...
CVE-2011-3320
Cross-site scripting XSS vulnerability in the Web Administrator component in GE Intelligent Platforms Proficy Historian 4.x and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified parameters...
CVE-2013-0654
CimWebServer in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to execute arbitrary commands or cause a denial of service daemon crash via a crafted packet...
CVE-2013-0653
Directory traversal vulnerability in substitute.bcl in the WebView CimWeb subsystem in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to read arbitrary files via a crafted packet...
CVE-2012-2516
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module aka the HTML Help component, as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other...
CVE-2012-4689
Integer overflow in CimWebServer.exe in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY 4.01 through 8.0, and Proficy Process Systems with CIMPLICITY, allows remote attackers to cause a denial of service daemon crash via a malformed HTTP request...
CVE-2013-2785
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted...
CVE-2025-3223
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in GE Vernova WorkstationST on Windows EGD Configuration Server modules allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier...
CVE-2025-3223
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in GE Vernova WorkstationST on Windows EGD Configuration Server modules allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier...
CVE-2025-3223
The CVE-2025-3223 entry concerns GE Vernova WorkstationST on Windows, specifically the EGD Configuration Server modules. The vulnerability is caused by improper limitation of a pathname to a restricted directory, enabling a path traversal in WorkstationST versions V07.10.10C and earlier. Document...
CVE-2025-3223 WorkstationST EGD Configuration Server Path Traversal Vulnerability
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in GE Vernova WorkstationST on Windows EGD Configuration Server modules allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier...
CVE-2025-3223 WorkstationST EGD Configuration Server Path Traversal Vulnerability
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in GE Vernova WorkstationST on Windows EGD Configuration Server modules allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier...
CVE-2025-3223: Improper Limitation of a Pathname to a Restricted Directory
Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in GE Vernova WorkstationST on Windows EGD Configuration Server modules allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier...
PT-2025-22085 · Ge · Ge Vernova Workstationst
Name of the Vulnerable Software and Affected Versions: GE Vernova WorkstationST versions V07.10.10C and earlier Description: The issue is related to an Improper Limitation of a Pathname to a Restricted Directory, also known as a 'Path Traversal' vulnerability, in the EGD Configuration Server...