1749 matches found
GE Proficy Historian ihDataArchiver.exe Multiple Opcode Parsing Remote Code Execution Vulnerabilities
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of GE iFix. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ihDataArchiver.exe process which listens by default on TCP port 14000. Several errors are...
CVE-2012-2515
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module aka the HTML Help component, as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1...
CVE-2012-2516
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module aka the HTML Help component, as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other...
CVE-2012-2515
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module aka the HTML Help component, as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1...
CVE-2012-2515
CVE-2012-2515 describes multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control (KeyHelp.ocx 1.2.312) in the KeyWorks KeyHelp Module (HTML Help component). The flaws allow remote code execution via a long string passed to the (1) JumpMappedID or (2) JumpURL methods, affecti...
CVE-2012-2516
The CVE-2012-2516 issue is an ActiveX-based command-injection vulnerability in KeyHelp.ocx of GE Intelligent Platforms’ KeyWorks KeyHelp module, affecting Proficy Historian (3.1, 3.5, 4.0, 4.5), Proficy HMI/SCADA – iFIX (5.0, 5.1), Proficy Pulse 1.0, Proficy Batch Execution 5.6, and SI7 I/O Drive...
CVE-2012-2516
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module aka the HTML Help component, as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other...
PT-2012-4075
Name of the Vulnerable Software and Affected Versions GE Intelligent Platforms Proficy Historian versions 3.1 through 4.5 Proficy HMI/SCADA iFIX versions 5.0 through 5.1 Proficy Pulse version 1.0 Proficy Batch Execution version 5.6 SI7 I/O Driver versions 7.20 through 7.42 Description The issue...
CVE-2012-2516: Improper Neutralization of Special Elements used in an OS Command
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module aka the HTML Help component, as used in GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; Proficy HMI/SCADA iFIX 5.0 and 5.1; Proficy Pulse 1.0; Proficy Batch Execution 5.6; SI7 I/O Driver 7.20 through 7.42; and other...
KLA10300 ACE vulnerability in GE IP products
A buffer overflow was found in GE IP products. By exploiting this vulnerability malicious users can execute arbitrary code and commands. This vulnerability can be exploited remotely via a specially designed input. Original advisories GE IP bulletin Exploitation Public exploits exist for this...
GE Intelligent Platforms Proficy Real-Time Information Portal Vulnerabilities
OVERVIEW This advisory is a follow-up to the previously updated portal advisory titled ICSA-12-234-01AP—GE Intelligent Platforms Proficy Real-Time Information Portal Multiple Vulnerabilities, which was published September 17, 2012, in the US-CERT secure Portal library. This advisory provides...
Memory corruption
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted TCP session on port 12299...
CVE-2012-0231
PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted TCP session on port 12401...
CVE-2012-0229
The Data Archiver service in GE Intelligent Platforms Proficy Historian 4.5 and earlier allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted session on TCP port 14000 to 1 ihDataArchiver.exe or 2 ihDataArchiverx64.exe...
CVE-2012-0230
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted TCP session on port 12299...
CVE-2012-0232
Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote attackers to modify the configuration via crafted strings...
Directory traversal
Directory traversal vulnerability in rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6, 3.0, 3.0 SP1, and 3.5 allows remote attackers to modify the configuration via crafted strings...
CVE-2012-0232
CVE-2012-0232 concerns GE Proficy Real-Time Information Portal. A directory traversal vulnerability exists in the Remote Interface Service (rifsrvd.exe) listening on TCP 5159, where two input strings used to create a configuration file are not sufficiently validated. Remote, unauthenticated attac...
CVE-2012-0229
The CVE-2012-0229 vulnerability affects GE Intelligent Platforms Proficy Historian: ihDataArchiver (ihDataArchiver.exe / ihDataArchiver_x64.exe) in Proficy Historian 4.5 and earlier. A memory corruption flaw exists in the Data Archiver service that processes network traffic on TCP port 14000, all...
CVE-2012-0230
PRRDS.exe in the Proficy Remote Data Service in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service memory corruption or possibly execute arbitrary code via a crafted TCP session on port 12299...