CVE-2001-1594
GE Healthcare eNTEGRA P&R has a password of 1 entegra for the entegra user, 2 passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, 3 0 for the entegra user of the Codonics printer FTP service, 4 eNTEGRA for the eNTEGRA P&R user account, 5 insite for the WinVNC Login, and...
CVE-2014-7233
GE Healthcare Precision THUNIS-800+ has a default password of 1 1973 for the factory default System Utilities menu, 2 TH8740 for installation using TH8740122Setup.exe, 3 hrml for "Setup and Activation" using DSASetup, and 4 an empty string for Shutter Configuration, which has unspecified impact a...
CVE-2007-6757
GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value...
CVE-2010-5307
The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of 1 operator for the root account, 2 adw2.0 for the admin account, and 3 adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcode...
CVE-2009-5143
GE Healthcare Discovery 530C has a password of bigguy1 for the 1 acqservice user and 2 wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires ...
CVE-2013-7442
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of 1 CANal1 for the Administrator user and 2 iis for the IIS user, which has unspecified impact and attack vectors related to TimbuktuPro. NOTE: it is not clear whether this password is default, hardcoded, or dependent on...
CVE-2009-5143
CVE-2009-5143 affects GE Healthcare Discovery NM530c (and is cited in ICSMA as part of a family of default/hard‑coded credential issues). The ICS-CERT advisory confirms improper authentication (default or hard-coded credentials) enabling remote access to vulnerable GE Healthcare imaging/workstati...
CVE-2010-5307
GE Healthcare Optima MR360 HIPAA configuration interface is affected by CVE-2010-5307, tied to built-in/default credentials (root: operator, admin: adw2.0, sdc: adw2.0). Public documentation confirms remote authentication bypass risk via these credentials and notes uncertainty on whether password...
CVE-2002-2446
GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabling product functionality for remote InSite support, which has unspecified impact and attack vectors...
CVE-2003-1603
GE Healthcare Discovery VH has a default password of 1 interfile for the ftpclient user of the Interfile server or 2 "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors...
CVE-2003-1603
CVE-2003-1603 affects GE Healthcare Discovery VH and Millenium VG (and related GE devices listed in ICS advisory) due to default/hard-coded credentials. Root cause: credentials (ftpclient: interfile; LOCAL: 2) left unchanged, enabling remote authentication bypass. Impact in sources: potential rem...
CVE-2013-7442
CVE-2013-7442 relates to GE Healthcare Centricity PACS Workstation and related Centricity PACS components using default or hard-coded credentials (e.g., CANal1 for Administrator and iis for IIS). The ICS-CERT advisory (GE Healthcare) lists affected products including Centricity PACS Server/ IW/ R...
CVE-2012-6660
GE Healthcare Precision MP/i is affected by a vulnerability (CVE-2012-6660) due to default or hard-coded credentials for multiple accounts: serviceapp uses the orion password, clinical operator uses orion, and administrator uses PlatinumOne. The ICS advisory (GE Healthcare vulnerability) confirms...
CVE-2010-5308
Affected product: GE Healthcare Optima MR360. Vulnerability: Emergency login screen allows access without authentication via arbitrary username, enabling physically proximate users to gain access. Root cause per sources is insufficient authentication on the HIPAA emergency login procedure. Impact...
CVE-2013-7405
The CVE-2013-7405 entry concerns GE Healthcare Centricity DMS 4.2, specifically the Ad Hoc Reporting feature where the Administrator password is set to Never!Mind. The core detail available across connected sources is that this password is problematic and that an attacker could potentially take c...
CVE-2006-7253
Ge Healthcare Infinia II is affected by CVE-2006-7253 due to the use of default credentials across five accounts (infinia, acqservice, Administrator, emergency, InfiniaAdmin). The CNVD-2015-05143 entry explicitly states that an attacker can exploit this to take control of the device, indicating a...
CVE-2012-6660
GE Healthcare Precision MPi has a password of 1 orion for the serviceapp user, 2 orion for the clinical operator user, and 3 PlatinumOne for the administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent ...
GE MDS PulseNET Vulnerabilities
OVERVIEW NCCIC/ICS-CERT received a report from HP’s Zero Day Initiative ZDI concerning two vulnerabilities in GE’s MDS PulseNET and MDS PulseNET Enterprise Network Management Software. These vulnerabilities were reported to ZDI by security researcher Andrea Micalizzi. GE has produced a new versio...
GE Fixes Buffer Overflow in DTM Library
GE has released a fix for a vulnerability in a library that’s used in several of its products deployed in critical infrastructure areas. The flaw in the HART Device Type Manager library could allow an attacker to crash affected applications or run arbitrary code. The vulnerability in the DTM...
GE Hydran M2 Guessable TCP Initialization Sequence Vulnerability
The GE Hydran M2 is a fault gas and moisture detection solution. The GE Hydran M2 that includes the 7046 Ethernet option generates guessable TCP initialization sequence numbers, allowing an attacker to predict the correct TCP initialization sequence number, send special messages, and falsify that...