CVE-2011-5323
GE Healthcare Centricity PACS-IW versions 3.7.3.7 and 3.7.3.8 (and possibly others) are documented as having a built-in sa SQL server account password, A11enda1e. The descriptions note the impact and attack vectors are unspecified and do not clarify whether this password is default, hardcoded, or...
CVE-2012-6695
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of ddpadmin for the ddpadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value...
CVE-2011-5324
CVE-2011-5324 affects GE Healthcare Centricity PACS-IW via the TeraRecon server. CNVD/NVD records indicate built-in accounts in PACS-IW with a shared password for the shared user and a password for the scan user (versions 3.7.3.7/3.7.3.8 mentioned). This design enables remote attackers to use the...
CVE-2010-5306
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of bigguy for the root user, which has unspecified impact and attack vectors...
CVE-2011-5322
GE Healthcare Centricity Analytics Server 1.1 has a default password of 1 V0yag3r for the SQL Server sa user, 2 G3car3s for the analyst user, 3 G3car3s for the ccg user, 4 V0yag3r for the viewer user, and 5 geservice for the geservice user in the Webmin interface, which has unspecified impact and...
CVE-2001-1594
GE Healthcare eNTEGRA P&R has a password of 1 entegra for the entegra user, 2 passme for the super user of the Polestar/Polestar-i Starlink 4 upgrade, 3 0 for the entegra user of the Codonics printer FTP service, 4 eNTEGRA for the eNTEGRA P&R user account, 5 insite for the WinVNC Login, and...
CVE-2010-5308
GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access...
CVE-2012-6694
GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1, and Server 4.0, has a password of 2charGE for the geservice account, which has unspecified impact and attack vectors related to TimbuktuPro. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system o...
CVE-2014-9736
GE Healthcare Centricity Clinical Archive Audit Trail Repository is affected by a default-password issue: initinit for the SSL key manager and server keystore, keystore_password for the server truststore, and atna for the primary and archive storage databases. This credential exposure can enable ...
CVE-2002-2446
The CVE-2002-2446 issue affects GE Healthcare Millennium MG / NC / MyoSIGHT (and related GE imaging systems) due to default or hard-coded credentials: the insite.genieacq password cannot be changed without disabling remote InSite support. This enables potential remote authentication bypass on aff...
CVE-2004-2777
GE Healthcare Centricity Image Vault 3.x is affected by an authentication issue due to default or hard-coded credentials across multiple components (including Image Vault 3.x itself and related GE products such as GEMNet License Server). The ICS-CERT advisory (and GE’s self-assessment) confirms r...
CVE-2010-5310
CVE-2010-5310 is mapped to the GE Healthcare Revolution XQ/i. Connected sources confirm the vulnerability stems from default or hard-coded credentials: the sdc user password is adw3.1, enabling potential remote control of affected devices. Affected products include Revolution XQ/i among a long li...
CVE-2012-6693
CVE-2012-6693 concerns GE Healthcare Centricity PACS Server with default credentials: nasro / nasro (ReadOnly) and nasrw (Read/Write). The connected documents confirm a default credential issue across Centricity PACS components, enabling remote access with these accounts. The primary root cause i...
CVE-2014-7233
CVE-2014-7233 concerns GE Healthcare Precision THUNIS-800+ with default credentials: factory System Utilities password (1973), installation password (TH8740), Setup/Activation password (hrml), and an empty Shutter password. Root cause is use of default/hard-coded credentials in multiple access po...
CVE-2012-6695
GE Healthcare Centricity PACS Workstation 4.0/4.0.1 uses a ddpadmin password for the ddpadmin user. The connected ICS advisory characterizes this as default or hard-coded credentials (CWE-287) with potential remote authentication bypass. Exploitation could allow remote access to affected devices,...
CVE-2010-5310
The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value...
CVE-2010-5306
This CVE concerns GE Healthcare Optima imaging systems (Optima 520/540/640/680) with default or hard-coded credentials, enabling remote authentication bypass. The ICS-CERT advisory (ICSMA-18-037-02) confirms multiple GE products affected; exploitation could allow an attacker to bypass authenticat...
CVE-2013-7404
CVE-2013-7404 affects the GE Healthcare Discovery NM750b. The issue arises from default/hard-coded credentials: the insite account password is 2getin for Telnet and FTP. This can enable remote authentication bypass and unauthorized access to the device as described by ICS-CERT and related sources...
CVE-2001-1594
CVE-2001-1594 relates to GE Healthcare eNTEGRA P&R and is mapped to default/hard-coded credentials across multiple GE devices (eNTEGRA 2.0/2.5 Workstation, and related imaging products). The connected sources confirm that the vulnerability enables authentication bypass by using known passwords (e...
CVE-2011-5322
GE Healthcare Centricity PACS-IW (Centricity PACS-IW) is vulnerable via default/hard-coded credentials documented for CVE-2011-5322 in Centricity Analytics Server 1.1, notably in the Webmin interface where several accounts use known passwords (e.g., V0yag3r, G3car3s, geservice). Exploitation coul...