Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.18 views

Siemens Simatic Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC S7-200 SMART CPU family All versions = V2.2 V2.5.1. Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation...

5CVSS2.7AI score0.01044EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.25 views

Siemens Sicam Use of Password Hash With Insufficient Computational Effort

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with local access to the device might be able to retrieve some passwords in clear text. File data ot500439.nasl...

2.1CVSS2.7AI score0.00195EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.27 views

Schneider-electric Modicon Missing Encryption of Sensitive Data

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...

5.7CVSS3.7AI score0.00206EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.18 views

Rockwellautomation Logix Improper Restriction of XML External Entity Reference

Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity XXE vulnerability, which may allow an attacker to view hostnames or other resources from the program. File data ot500474.nasl...

4.3CVSS3.9AI score0.01545EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.21 views

Emerson Deltav Improper Input Validation

Buffer overflow in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows user-assisted remote attackers to execute arbitrary code or cause a denial of service daemon crash via an invalid field in a project file. File data...

7.5CVSS6.8AI score0.03971EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.31 views

Schneider-electric Modicon Improper Input Validation

Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP. File data ot500446.nasl...

7.8CVSS2.5AI score0.00978EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.31 views

Schneider-electric Modicon Inadequate Encryption Strength

A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. File data...

7.3CVSS4.6AI score0.00296EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.24 views

Rockwellautomation Micrologix Unspecified Vulnerability

An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000...

5CVSS2.4AI score0.04639EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.62 views

Rockwellautomation Factorytalk Improper Input Validation

All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution RCE. Rockwell Automation recommends applying patch...

6.8CVSS2.9AI score0.46968EPSS
SaveExploits3References4
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Rockwellautomation Factorytalk Heap-based Buffer Overflow

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution. File data ot500476.nasl...

7.5CVSS4.8AI score0.06815EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.18 views

Schneider-electric Modicon Unspecified Vulnerability

A CWE-334: Small Space of Random Values vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to break the encryption keys when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller. File data...

7.3CVSS4.6AI score0.00296EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.27 views

Siemens Sicam Protection Mechanism Failure

A vulnerability has been identified in SICAM A8000 CP-8000 All versions V16, SICAM A8000 CP-8021 All versions V16, SICAM A8000 CP-8022 All versions V16. A web server misconfiguration of the affected device can cause insecure ciphers usage by a user´s browser. An attacker in a privileged position...

4.9CVSS3.8AI score0.00571EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Johnsoncontrols Metasys Use of Hard-coded Credentials

Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a shared RSA key pair for certain encryption operations involving the Site Management Portal SMP. File data ot500401.nasl...

9.1CVSS2.9AI score0.0082EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.21 views

Rockwellautomation Micrologix Channel Accessible by Non-Endpoint

When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...

5CVSS3AI score0.02982EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.21 views

Rockwellautomation Factorytalk Allocation of Resources Without Limits or Throttling

An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk...

2.1CVSS3.9AI score0.04776EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.23 views

Mitsubishielectric Q03udecpu Unspecified Vulnerability

Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands. File data ot500429.nasl...

7.5CVSS6.5AI score0.0227EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.26 views

Siemens Sinumerik Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC TDC CPU555 All versions, SINUMERIK 840D sl All versions. Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port...

7.8CVSS3.7AI score0.01666EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.30 views

Johnsoncontrols Metasys Improper Privilege Management

Successful exploitation of this vulnerability could give an authenticated Metasys user an unintended level of access to the server file system, allowing them to access or modify system files by sending specifically crafted web messages to the Metasys system. This issue affects: Johnson Controls...

8.8CVSS3.6AI score0.01245EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.33 views

Schneider-electric Unity Write-what-where Condition

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert all versions and Unity Pro former name of EcoStruxure™ Control Expert all versions, that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control...

6.8CVSS3.8AI score0.01447EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.30 views

Rockwellautomation Factorytalk Use of Password Hash With Insufficient Computational Effort