Lucene search
+L

1213 matches found

Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.20 views

Rockwellautomation Micrologix Channel Accessible by Non-Endpoint

When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the controller Micro800: Al...

5CVSS3AI score0.02188EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.25 views

Johnsoncontrols Metasys Improper Privilege Management

Successful exploitation of this vulnerability could give an authenticated Metasys user an unintended level of access to the server file system, allowing them to access or modify system files by sending specifically crafted web messages to the Metasys system. This issue affects: Johnson Controls...

8.8CVSS3.6AI score0.01245EPSS
Exploits0References4
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.22 views

Emerson Deltav Unspecified Vulnerability

An unspecified ActiveX control in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to overwrite arbitrary files via unknown vectors. File data ot500393.nasl...

6.4CVSS5.3AI score0.01886EPSS
Exploits0References5
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.34 views

Se Ecostruxure Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, coul...

9.8CVSS2.3AI score0.01557EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.24 views

Saia_burgess_controls Pcd Exposure of Sensitive Information to an Unauthorized Actor

An Information Exposure issue was discovered in Saia Burgess Controls PCD Controllers with PCD firmware versions prior to 1.28.16 or 1.24.69. In certain circumstances, the device pads Ethernet frames with memory contents. File data ot500391.nasl...

5CVSS3.1AI score0.01233EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.23 views

Schneider-electric Modicon Missing Encryption of Sensitive Data

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...

5.7CVSS3.7AI score0.00201EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.24 views

Siemens Sicam Missing Authentication for Critical Function

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the network could be able to install specially crafted firmware to the device. File data ot500482.nasl...

5CVSS4.2AI score0.00826EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.24 views

Siemens Sicam Protection Mechanism Failure

A vulnerability has been identified in SICAM A8000 CP-8000 All versions V16, SICAM A8000 CP-8021 All versions V16, SICAM A8000 CP-8022 All versions V16. A web server misconfiguration of the affected device can cause insecure ciphers usage by a user´s browser. An attacker in a privileged position...

4.9CVSS3.8AI score0.00564EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.30 views

Johnsoncontrols Metasys Use of Hard-coded Credentials

Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a hardcoded RC2 key for certain encryption operations involving the Site Management Portal SMP. File data ot500384.nasl...

9.1CVSS2.5AI score0.00632EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.56 views

Rockwellautomation Factorytalk Improper Input Validation

All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution RCE. Rockwell Automation recommends applying patch...

6.8CVSS2.9AI score0.46968EPSS
Exploits4References4
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.21 views

Siemens Sinumerik Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC TDC CPU555 All versions, SINUMERIK 840D sl All versions. Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port...

7.8CVSS3.7AI score0.01601EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.30 views

Schneider-electric Unity Write-what-where Condition

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert all versions and Unity Pro former name of EcoStruxure™ Control Expert all versions, that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control...

6.8CVSS3.8AI score0.01387EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.18 views

Johnsoncontrols Metasys Use of Hard-coded Credentials

Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a shared RSA key pair for certain encryption operations involving the Site Management Portal SMP. File data ot500401.nasl...

9.1CVSS2.9AI score0.0082EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.42 views

Siemens Simatic Improper Restriction of Operations within the Bounds of a Memory Buffer

The 1 TLS and 2 DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys,...

5CVSS2.9AI score0.99999EPSS
Exploits90References128
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.15 views

Siemens Simatic Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC S7-200 SMART CPU family All versions = V2.2 V2.5.1. Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation...

5CVSS2.7AI score0.01044EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.24 views

Rockwellautomation Flex Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a...

7.8CVSS2.4AI score0.03558EPSS
Exploits1References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.28 views

Rockwellautomation Factorytalk Improper Input Validation

A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device. File data ot500455.nasl...

7.8CVSS5.3AI score0.01578EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.22 views

Abb Base Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl all published versions enables an attacker authenticated on the local system to inject data, affecting the online view...

5.3CVSS3.8AI score0.00325EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.30 views

Schneider-electric Modicon Out-of-bounds Write

Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller V5.0.0.7 and prior which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4...

7.5CVSS2.6AI score0.01387EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:0 a.m.26 views

Rockwellautomation Factorytalk Use of Password Hash With Insufficient Computational Effort

In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly. File data ot500427.nasl...

7.5CVSS3.2AI score0.04095EPSS
Exploits0References2
Rows per page
Query Builder