Lucene search
+L

1220 matches found

Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.28 views

Rockwellautomation Factorytalk Improper Handling of Exceptional Conditions

An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpys if a local user opens FactoryTalk Diagnosti...

5CVSS2.5AI score0.33836EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.20 views

Rockwellautomation Flex Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

An exploitable denial of service vulnerability exists in the ENIP Request Path Network Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a...

5CVSS2.8AI score0.03454EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.29 views

Johnsoncontrols Bcpro Unspecified Vulnerability

In Johnson Controls Metasys System Versions 8.0 and prior and BCPro BCM all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information. File data ot500468.nasl...

6.5CVSS3.5AI score0.00877EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.22 views

Yokogawa Centum Improper Authentication

CAMS for HIS CENTUM CS 3000 includes CENTUM CS 3000 Small R3.08.10 to R3.09.50, CENTUM VP includes CENTUM VP Small, Basic R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to bypass authentication and send altered...

7.5CVSS5.4AI score0.01587EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.33 views

Se Ecostruxure Cleartext Transmission of Sensitive Information

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. File data ot500400.nasl...

7.5CVSS2.2AI score0.00876EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.21 views

Siemens Sicam Missing Authentication for Critical Function

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the device's web server might be able to execute administrative commands without authentication. File data ot500430.nasl...

7.5CVSS4AI score0.01235EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.27 views

Siemens Sicam Missing Authentication for Critical Function

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker with access to the network could be able to install specially crafted firmware to the device. File data ot500482.nasl...

5CVSS4.2AI score0.00826EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.21 views

Siemens Sicam Authentication Bypass by Capture-replay

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application. File data...

6.8CVSS4.8AI score0.01066EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.29 views

Schneider-electric Modicon Out-of-bounds Write

A CWE-787: Out-of-bounds Write vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause corruption of data, a crash, or code execution when uploading a specially crafted...

6.5CVSS4.1AI score0.01129EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.19 views

Johnsoncontrols Metasys Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

Path Traversal vulnerability exists in Metasys Reporting Engine MRE Web Services which could allow a remote unauthenticated attacker to access and download arbitrary files from the system. File data ot500390.nasl...

7.5CVSS4.1AI score0.03787EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.26 views

Rockwellautomation Micrologix Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...

7.5CVSS3.3AI score0.01719EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.24 views

Siemens Sicam Out-of-bounds Read

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information. File...

5CVSS4AI score0.01071EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.15 views

Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially...

5.3CVSS1.3AI score0.00925EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.18 views

Siemens Sicam Missing Encryption of Sensitive Data

A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to...

6.8CVSS3.9AI score0.00523EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.35 views

Se Ecostruxure Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, coul...

9.8CVSS2.3AI score0.01596EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.49 views

Saia_burgess_controls Pcd1.m0xx0 Unspecified Vulnerability

Saia Burgess PCD1.M0xx0, PCD1.M2xx0, PCD2.M5xx0, PCD3.Mxx60, PCD3.Mxxx0, PCD7.D4xxD, PCD7.D4xxV, PCD7.D4xxWTPF, and PCD7.D4xxxT5F devices before 1.24.50 and PCD3.T665 and PCD3.T666 devices before 1.24.41 have hardcoded credentials, which allows remote attackers to obtain administrative access via...

10CVSS6.3AI score0.02419EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.36 views

Rockwellautomation Factorytalk Improper Restriction of Operations within the Bounds of a Memory Buffer

In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installi...

4.6CVSS2.2AI score0.006EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.24 views

Emerson Deltav Unspecified Vulnerability

An unspecified ActiveX control in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to overwrite arbitrary files via unknown vectors. File data ot500393.nasl...

6.4CVSS5.3AI score0.01886EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.28 views

Saia_burgess_controls Pcd Exposure of Sensitive Information to an Unauthorized Actor

An Information Exposure issue was discovered in Saia Burgess Controls PCD Controllers with PCD firmware versions prior to 1.28.16 or 1.24.69. In certain circumstances, the device pads Ethernet frames with memory contents. File data ot500391.nasl...

5CVSS3.1AI score0.01233EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2021/08/10 12:00 a.m.44 views

Siemens Simatic Improper Restriction of Operations within the Bounds of a Memory Buffer

The 1 TLS and 2 DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys,...

5CVSS2.9AI score0.99999EPSS
SaveExploits95References128
Rows per page
Query Builder