8857 matches found
CISA Releases Six Industrial Control Systems Advisories
CISA released six Industrial Control Systems ICS advisories on February 6, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-037-01 Schneider Electric EcoStruxure Power Monitoring Expert PME ICSA-25-037-02...
CVE-2022-25164
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-3085
Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to a stack-based buffer overflow which may allow an attacker to execute arbitrary code...
CVE-2022-29831
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules...
CVE-2022-29830
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control SettingGX Works3 related software versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a...
CVE-2022-33323
Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected mod...
CVE-2022-37681
Hitachi Kokusai Electric Newtork products for monitoring system Camera, Decoder and Encoder and below allows attckers to perform a directory traversal via a crafted GET request to the endpoint /ptippage.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue...
CVE-2022-40265
Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version "65" and prior allows a remote unauthenticated attacker...
CVE-2019-6834
A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneide...
CVE-2020-14496
Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information ...
CVE-2024-34171
Fuji Electric Monitouch V-SFT is vulnerable to a stack-based buffer overflow, which could allow an attacker to execute arbitrary code...
CVE-2024-5271
Fuji Electric Monitouch V-SFT is vulnerable to an out-of-bounds write because of a type confusion, which could result in arbitrary code execution...
CVE-2024-5597
Fuji Electric Monitouch V-SFT is vulnerable to a type confusion, which could cause a crash or code execution...
CVE-2024-1182
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electri...
CVE-2024-9852
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric...
Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408)
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. This plugin only works with Tenable.ot...
CVE-2024-8403
Improper Validation of Specified Type of Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET versions 1.100 to 1.200 and FX5-ENET/IP versions 1.100 to 1.104 allows a remote attacker to cause a Denial of Service condition in Ethernet communication of the products by...
CVE-2024-8340
A vulnerability classified as critical has been found in SourceCodester Electric Billing Management System 1.0. This affects an unknown part of the file /Actions.php?a=login. The manipulation of the argument username leads to sql injection. It is possible to initiate the attack remotely. The...
CVE-2024-8300
Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97...
CVE-2024-8299
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric...