8158 matches found
CVE-2024-5271
Fuji Electric Monitouch V-SFT is vulnerable to an out-of-bounds write because of a type confusion, which could result in arbitrary code execution...
CVE-2024-5597
Fuji Electric Monitouch V-SFT is vulnerable to a type confusion, which could cause a crash or code execution...
CVE-2024-1182
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electri...
CVE-2024-9852
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric...
Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408)
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. This plugin only works with Tenable.ot...
CVE-2024-8403
Improper Validation of Specified Type of Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET versions 1.100 to 1.200 and FX5-ENET/IP versions 1.100 to 1.104 allows a remote attacker to cause a Denial of Service condition in Ethernet communication of the products by...
CVE-2024-8340
A vulnerability classified as critical has been found in SourceCodester Electric Billing Management System 1.0. This affects an unknown part of the file /Actions.php?a=login. The manipulation of the argument username leads to sql injection. It is possible to initiate the attack remotely. The...
CVE-2024-8300
Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97...
CVE-2024-8299
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric...
Schneider Electric Web Designer for Modicon
RISK EVALUATION Successful exploitation of this vulnerability could result in information disclosure, workstation integrity and potential remote code execution on the compromised computer. 2. RECOMMENDED PRACTICES CISA reminds organizations to perform proper impact analysis and risk assessment...
CISA Releases Eight Industrial Control Systems Advisories
CISA released eight Industrial Control Systems ICS advisories on January 30, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-030-01 Hitachi Energy UNEM ICSA-25-030-02 New Rock Technologies Cloud Connected...
Schneider Electric EcoStruxure Power Monitoring Expert 跨站脚本漏洞
The Schneider Electric EcoStruxure Power Monitoring Expert is a device from Schneider Electric France for power distribution monitoring in IoT environments. A cross-site scripting vulnerability exists in the Schneider Electric EcoStruxure Power Monitoring Expert, which arises from improper input...
The software for creating automation projects of Schneider Electric’s Web Designer network modules BMXNOE0110H, BMENOC0311C, BMENOC0321C, and BMXNOR0200H is vulnerable due to incorrect restrictions on XML references to external objects. This vulnerability allows attackers to compromise the confidentiality, integrity, and accessibility of the protected information.
The vulnerability of the software used for creating automation projects in Schneider Electric’s Web Designer for network modules BMXNOE0110H, BMENOC0311C, BMENOC0321C, and BMXNOR0200H is related to incorrect restrictions on XML references to external objects. Exploiting this vulnerability allows ...
Fuji Electric Alpha5 SMART Stack Buffer Overflow Vulnerability
The Fuji Electric Alpha5 SMART is a high-performance AC servo system designed for high-speed and high-precision control. A stack buffer overflow vulnerability exists in the Fuji Electric Alpha5 SMART. The vulnerability is due to the system failing to perform proper boundary checks on input data...
CVE-2024-34579
Fuji Electric Alpha5 SMART is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code...
CVE-2024-34579 Fuji Electric Alpha5 SMART Stack-Based Buffer Overflow
Fuji Electric Alpha5 SMART is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code...
CVE-2024-34579
The evidence in Connected documents identifies Fuji Electric Alpha5 Smart (Alpha5 SMART) as affected by a stack-based buffer overflow in C5V file parsing. The root cause is failure to validate the length of user-supplied data prior to copying it to a stack-based buffer, enabling potential arbitra...
CVE-2024-34579 Fuji Electric Alpha5 SMART Stack-Based Buffer Overflow
Fuji Electric Alpha5 SMART is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code...
Fuji Electric Alpha5 SMART 安全漏洞
The Fuji Electric Alpha5 SMART is a high-performance AC servo system designed for high-speed and high-precision control. A stack buffer overflow vulnerability exists in the Fuji Electric Alpha5 SMART. The vulnerability is due to the system failing to perform proper boundary checks on input data...
Schneider Electric Pro-face GP-Pro EX和Remote HMI 安全漏洞
Schneider Electric Pro-face GP-Pro EX and Schneider Electric Pro-face Remote HMI are both products of Schneider Electric, France.Schneider Electric Pro-face GP-Pro EX is an HMI operation management system. Schneider Electric Pro-face GP- EX is a human-machine interface operator management system,...