Lucene search
+L

1524 matches found

The Hacker News
The Hacker News
added 2022/06/28 11:30 a.m.225 views

APT Hackers Targeting Industrial Control Systems with ShadowPad Backdoor

Entities located in Afghanistan, Malaysia, and Pakistan are in the crosshairs of an attack campaign that targets unpatched Microsoft Exchange Servers as an initial access vector to deploy the ShadowPad malware. Russian cybersecurity firm Kaspersky, which first detected the activity in mid-October...

9.8CVSS2.2AI score0.99996EPSS
SaveExploits65
Positive Technologies
Positive Technologies
added 2022/06/28 12:00 a.m.12 views

PT-2022-4220 · Yokogawa · Exaopc +5

Name of the Vulnerable Software and Affected Versions: CENTUM CS 3000 versions R3.08.10 through R3.09.00 CENTUM VP versions R4.01.00 through R4.03.00 CENTUM VP versions R5.01.00 through R5.04.20 CENTUM VP versions R6.01.00 through R6.09.00 Exaopc versions R3.72.00 through R3.80.00 B/M9000 CS...

8.8CVSS8.3AI score0.0058EPSS
SaveExploits0References7
BDU FSTEC
BDU FSTEC
added 2022/06/28 12:00 a.m.17 views

The vulnerability of Emerson DeltaV industrial control stations, related to the use of cryptographic algorithms containing vulnerabilities, allows an intruder to gain access to the system’s control interface.

The vulnerability of Emerson DeltaV industrial control stations lies in the use of cryptographic algorithms that contain vulnerabilities. Exploiting this vulnerability can allow an attacker operating remotely to gain access to the system’s control interface...

9CVSS5.5AI score0.00175EPSS
SaveExploits0References2
ICS
ICS
added 2022/06/28 12:00 a.m.78 views

Motorola Solutions MOSCAD IP and ACE IP Gateways

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely Vendor: Motorola Solutions Equipment: MOSCAD IP Gateway and ACE IP Gateway Vulnerability: Missing Authentication for Critical Function CISA is aware of a public report, known as “OT:ICEFALL” that details vulnerabilities found in...

7.5CVSS8AI score0.00777EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2022/06/27 12:00 a.m.12 views

The vulnerability of the EpicMo protocol lies in its ability to exploit measurement-and-control controllers from the Experion LX, allowing attackers to cause service failures.

The vulnerability of the EpicMo protocol, which is implemented in measurement and control controllers of the Experion LX, is related to deficiencies in the authentication process. Exploiting this vulnerability could allow a malicious actor to cause service failures remotely...

7.8CVSS5.5AI score0.00849EPSS
SaveExploits0References4
ICS
ICS
added 2022/06/23 12:00 a.m.88 views

Elcomplus SmartICS

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Elcomplus LLC Equipment: SmartICS Vulnerabilities: Improper Access Control, Relative Path Traversal, Cross-site Scripting 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow...

9CVSS6.3AI score0.00834EPSS
SaveExploits0References4
Circl
Circl
added 2022/06/16 12:21 p.m.11 views

CVE-2022-31625

creationtimestamp| type| source ---|---|--- 2022-06-16 12:21:16+00:00| seen| https://t.me/cibsecurity/44607 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...

8.1CVSS8.2AI score0.0379EPSS
SaveExploits1References2
Circl
Circl
added 2022/06/16 12:21 p.m.6 views

CVE-2022-31626

creationtimestamp| type| source ---|---|--- 2022-06-16 12:21:14+00:00| seen| https://t.me/cibsecurity/44605 2022-06-23 10:22:39+00:00| published-proof-of-concept| https://t.me/ptswarm/132 2022-06-23 23:53:55+00:00| published-proof-of-concept| https://t.me/MrVGunz/256 2022-06-25 12:47:01+00:00|...

8.8CVSS8.3AI score0.58123EPSS
SaveExploits3References11
Vulnrichment
Vulnrichment
added 2022/06/15 8:18 p.m.11 views

CVE-2022-24946

Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V firmware versions "16" and prior, Mitsubishi Electric MELSEC-Q Series Q03UDECPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/10/13/20/26/50/100UDEHCPU the...

7.1AI score0.0165EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/06/14 12:00 a.m.11 views

Siemens Spectrum Power 信任管理问题漏洞

Spectrum Power provides the basic components for SCADA, communications and data modeling for control and monitoring systems. Application suites can be added to optimize network and generation management in all areas of energy management.Spectrum Power MGMS is an advanced control and optimization...

8.8CVSS5.6AI score0.00396EPSS
SaveExploits0References3
ICS
ICS
added 2022/06/14 12:00 a.m.63 views

Meridian Cooperative Meridian

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Meridian Cooperative Equipment: Meridian Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could result in a disclosure of sensitive information...

5.3CVSS5.3AI score0.01104EPSS
SaveExploits0References5
ICS
ICS
added 2022/06/14 12:00 a.m.57 views

Mitsubishi Electric MELSEC-Q/L and MELSEC iQ-R

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: MELSEC-Q/L Series and iQ-R Series Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could result in a denial-of-service condition and/or...

10CVSS9.8AI score0.02223EPSS
SaveExploits0References4
HackRead
HackRead
added 2022/06/13 1:10 p.m.21 views

Vulnerabilities in Industrial Control Systems Lets Attackers Remotely Unlock Doors

By Deeba Ahmed In total, eight zero-day vulnerabilities have been detected in Carrier’s industrial control systems ICS which, if exploited, allow… This is a post from HackRead.com Read the original post: Vulnerabilities in Industrial Control Systems Lets Attackers Remotely Unlock Doors...

4.7AI score
SaveExploits0
The Hacker News
The Hacker News
added 2022/06/10 7:03 a.m.89 views

Researchers Disclose Critical Flaws in Industrial Access Controllers from HID Mercury

As many as four zero-day security vulnerabilities have been disclosed in the HID Mercury access controller system that's used widely in healthcare, education, transportation, and government facilities. "The vulnerabilities uncovered allowed us to demonstrate the ability to remotely unlock and loc...

10CVSS0.5AI score0.02406EPSS
SaveExploits0
ICS
ICS
added 2022/05/31 12:00 a.m.223 views

Fuji Electric Alpha7 PC Loader

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Fuji Electric Equipment: Alpha7 PC Loader Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED...

7.8CVSS8AI score0.0027EPSS
SaveExploits0References5
BDU FSTEC
BDU FSTEC
added 2022/05/30 12:00 a.m.12 views

The vulnerability of the CAMS for HIS distributed control systems management component is related to violations of security design principles. This allows attackers to access protected information or cause service failures.

The vulnerability of the CAMS for HIS distributed control systems’ emergency message and event management components is related to violations of secure design principles. Exploiting this vulnerability could allow an attacker operating remotely to gain access to protected information or cause...

6.4CVSS5.5AI score
SaveExploits0References1
ThreatPost
ThreatPost
added 2022/05/27 10:32 a.m.70 views

Critical Flaws in Popular ICS Platform Can Trigger RCE

Critical flaws in a popular platform used by industrial control systems ICS that allow for unauthorized device access, remote code execution RCE or denial of service DoS could threaten the security of critical infrastructure. OAS—offered by a company of the same name–makes it easy to transfer dat...

9.8CVSS8.5AI score0.37639EPSS
SaveExploits8References21
ICS
ICS
added 2022/05/24 12:00 a.m.91 views

Matrikon OPC Server

1. EXECUTIVE SUMMARY CVSS v3 5.8 ATTENTION: Exploitable remotely Vendor: Matrikon, a subsidiary of Honeywell Equipment: Matrikon OPC Server Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve remote command...

9CVSS7.7AI score0.0067EPSS
SaveExploits0References5
ATTACKERKB
ATTACKERKB
added 2022/05/20 1:15 p.m.6 views

CVE-2022-27640

A vulnerability has been identified in SIMATIC CP 442-1 RNA All versions V1.5.18, SIMATIC CP 443-1 RNA All versions V1.5.18. The affected devices improperly handles excessive ARP broadcast requests. This could allow an attacker to create a denial of service condition by performing ARP storming...

6.5CVSS5.7AI score0.00363EPSS
SaveExploits0References2
ICS
ICS
added 2022/05/17 12:00 a.m.79 views

Circutor COMPACT DC-S BASIC

1. EXECUTIVE SUMMARY CVSS v3 6.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Circutor Equipment: COMPACT DC-S BASIC Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a buffer overflow condition resulting in...

8.1CVSS8.1AI score0.00777EPSS
SaveExploits0References6
Rows per page
Query Builder