11849 matches found
PHPGurukul Dairy Farm Shop Management System: Trust management vulnerabilities
Dairy Farm Shop Management System is a PHP and MySQL based dairy farm management system . A hard-coded vulnerability exists in the Dairy Farm Shop Management System, which stems from hard-coded credentials in the code that can be exploited by an attacker to access the control panel...
CVE-2022-22766: Use of Hard-coded Credentials
Hardcoded credentials are used in specific BD Pyxis products. If exploited, threat actors may be able to gain access to the underlying file system and could potentially exploit application files for information that could be used to decrypt application credentials or gain access to electronic...
CVE-2020-36062: Use of Hard-coded Credentials
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised...
CVE-2022-22813
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration...
Hardcoded credentials
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration...
CVE-2022-22813
CVE-2022-22813 describes a CWE-798 hard-coded credentials issue in Schneider Electric Easergy P40 devices, where if an attacker obtains the TLS cryptographic key and takes control of the Courier tunneling/communication network, they could observe and manipulate product configuration traffic. Affe...
CVE-2021-45106: Use of Hard-coded Credentials
A vulnerability has been identified in SICAM TOOLBOX II All versions. Affected applications use a circumventable access control within a database service. This could allow an attacker to access the database...
CVE-2022-22813: Use of Hard-coded Credentials
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration...
PT-2022-6633 · Schneider Electric · Schneider Electric Easergy P40
Name of the Vulnerable Software and Affected Versions: Schneider Electric Easergy P40 affected versions not specified Description: A Use of Hard-coded Credentials issue exists, potentially allowing an attacker to observe and manipulate traffic associated with product configuration if they obtain...
Siemens SICAM TOOLBOX II (Update A)
1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM TOOLBOX II Vulnerability: Use of Hard-coded Credentials 2. UPDATE INFORMATION This advisory update is a follow-up to the original advisory titled ICSA-22-041-05 SICAM TOOLBOX II...
Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14930)
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin and mitsadm...
Rockwell Automation MicroLogix Controllers and RSLogix 500 Software Use of Hard-Coded Cryptographic Key (CVE-2020-6990)
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file...
Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU Use of Hard-Coded Credentials (CVE-2019-14926)
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard- coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware...
CVE-2021-42833: Use of Hard-coded Credentials
A Use of Hardcoded Credentials vulnerability exists in AquaView versions 1.60, 7.x, and 8.x that could allow an authenticated local attacker to manipulate users and system settings...
Schneider Electric Modicon M221 PLCs and SoMachine Basic Use of Hard-Coded Cryptographic Key (CVE-2017-7574)
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded- key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML...
Schneider Electric Quantum Ethernet Module Hard-Coded Credentials (CVE-2011-4859)
The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771 and 140CPU65 modules, the Premium TSXETY and TSXP57 modules, the M340 BMXNOE01 and BMXP3420 modules, and the STB DIO STBNIC2212 and STBNIP2 modules, uses hardcoded passwords for the 1 AUTCSE, 2 AUTCSE, 3 fdrusers, 4...
CVE-2022-22722
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could result in information disclosure. If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to the product they could potentially observe and...
CVE-2022-22722
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could result in information disclosure. If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to the product they could potentially observe and...
CVE-2022-22722
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could result in information disclosure. If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to the product they could potentially observe and...
CVE-2022-22722
The CVE-2022-22722 vulnerability affects Schneider Electric Easergy P5 (and related P3 issues) with a root cause of hard-coded credentials that could enable an attacker who gains SSH access to observe and manipulate device-config traffic, potentially leading to information disclosure and control ...