Lucene search
K

11 matches found

CNVD
CNVD
added 2023/10/11 12:0 a.m.19 views

Siemens SINEC NMS Incorrect Privilege Assignment Vulnerability

Siemens SINEC NMS is a network management system NMS from Siemens, Germany, that can be used 24/7 to centrally monitor, manage and configure industrial networks with tens of thousands of devices, including safety-related areas. The Siemens SINEC NMS suffers from an Incorrect Privilege Assignment...

7.8CVSS7.7AI score0.0008EPSS
Exploits0References1
OSV
OSV
added 2018/04/30 3:29 p.m.0 views

CVE-2017-9658

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this...

6.5CVSS5.8AI score0.00327EPSS
Exploits0References3
Prion
Prion
added 2018/04/30 3:29 p.m.10 views

Input validation

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor,...

3.3CVSS6.7AI score0.0036EPSS
Exploits0References3Affected Software1
Prion
Prion
added 2018/04/30 3:29 p.m.9 views

Input validation

Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this...

6.1CVSS7.1AI score0.00327EPSS
Exploits0References3Affected Software1
ATTACKERKB
ATTACKERKB
added 2018/04/30 3:29 p.m.2 views

CVE-2017-9657

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor,...

6.5CVSS5.5AI score0.0036EPSS
Exploits0References4
OSV
OSV
added 2018/04/30 3:29 p.m.2 views

CVE-2017-9657

Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor,...

6.5CVSS5.8AI score
Exploits0References3
CVE
CVE
added 2018/04/30 3:0 p.m.39 views

CVE-2017-9657

The CVE-2017-9657 entry describes an 802.11 WLAN issue in Philips IntelliVue MX40 (Version B.06.18) where partial re-association to the central monitor can leave the MX40 in telemetry mode while the central station expects local monitoring, potentially delaying alarms. Root causes cited include I...

6.5CVSS6.2AI score0.0036EPSS
Exploits0References3Affected Software1
CNVD
CNVD
added 2017/09/13 12:0 a.m.1 views

Unspecified Vulnerability in Philips' IntelliView MX40 Patient Worn Monitor (CNVD-2017-26427)

The MX40 Patient Worn Monitor is primarily used as a traditional telemetry medical device as part of a surveillance and alarm system. Under certain 802.11 network conditions, when hospital staff reset the device and re-establish it to a Wi-Fi access point, the MX40 can connect to an alternate...

6.5CVSS6.4AI score0.00327EPSS
Exploits0References1
CNVD
CNVD
added 2017/09/13 12:0 a.m.2 views

Unspecified Vulnerability in Philips' IntelliView MX40 Patient Worn Monitor

The MX40 Patient Worn Monitor is primarily used as a traditional telemetry medical device as part of a surveillance and alarm system. Under certain 802.11 network conditions, it is possible to partially re-associate the MX40 WLAN Monitor to a central monitoring station. In this state, the central...

6.5CVSS6.4AI score0.0036EPSS
Exploits0References1
Packet Storm
Packet Storm
added 2016/03/01 12:0 a.m.38 views

perfact::mpa Persistent Cross Site Scripting

-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 Advisory ID: SYSS-2015-066 Product: perfact::mpa Manufacturer: PerFact Innovation GmbH & Co. KG Affected Versions: Custom versions using PerFact DBUtils Toolkit v3.2 Tested Versions: Custom version with PerFact DBUtils Toolkit v3.2 Vulnerability Typ...

7.4AI score
Exploits0
The Hacker News
The Hacker News
added 2013/07/13 3:54 p.m.10 views

BlackBerry allows Indian government to Intercept emails and Chats

In 2010 the Indian authorities threatened to shut down BlackBerry's infrastructure unless it agreed to comply with lawful access requirements providing the government a way to intercept messages in order to prevent terrorist attacks. The long time dispute between the Indian government and...

6.6AI score
Exploits0
Rows per page
Query Builder