647 matches found
CVE-2019-3915
CVE-2019-3915 applies to Verizon Fios Quantum Gateway (G1100) firmware 02.01.00.05. The vulnerability is an authentication bypass via capture‑replay: because the web admin interface relies on HTTP (not HTTPS), an adjacent‑network attacker can intercept login requests and replay them to gain admin...
CVE-2019-3915: Authentication Bypass by Capture-replay
Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...
PT-2019-16770
Name of the Vulnerable Software and Affected Versions Verizon Fios Quantum Gateway G1100 version 02.01.00.05 Description The issue allows an unauthenticated attacker with adjacent network access to intercept and replay login requests, gaining access to the administrative web interface through an...
CVE-2019-9659: Authentication Bypass by Capture-replay
The Chuango 433 MHz burglar-alarm product line uses static codes in the RF remote control, allowing an attacker to arm, disarm, or trigger the alarm remotely via replay attacks, as demonstrated by Chuango branded products, and non-Chuango branded products such as the Eminent EM8617 OV2 Wifi Alarm...
CVE-2018-19023: Authentication Bypass by Capture-replay
Hetronic Nova-M prior to verson r161 uses fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state...
Security Vulnerability in Internet-Connected Construction Cranes
This seems bad: The F25 software was found to contain a capture replay vulnerability -- basically an attacker would be able to eavesdrop on radio transmissions between the crane and the controller, and then send their own spoofed commands over the air to seize control of the crane. "These devices...
CVE-2018-17935: Authentication Bypass by Capture-replay
All versions of Telecrane F25 Series Radio Controls before 00.0A use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state...
Telecrane F25 Series
1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Low skill level to exploit Vendor: Telecrane Equipment: F25 Series Vulnerability: Authentication Bypass by Capture-Replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthorized users to view commands, replay commands,...
CVE-2018-17176: Authentication Bypass by Capture-replay
A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication always transmitted in cleartext can be replayed to /bin/webserver on port 8081. There are no nonces, and timestamps are not checked at all...
CVE-2018-7790: Authentication Bypass by Capture-replay
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a...
CVE-2018-14781 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay
Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...
CVE-2018-14781
CVE-2018-14781 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps (e.g., MMT-508, MMT-511/512/712, MMT-515/723, MMT-522/723 REAL-TIME, MMT-551/751, etc.). Root cause: Authentication Bypass by Capture-replay when paired with a remote controller with non-default easy bol...
CVE-2018-14781
Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...
Default configuration
Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the "easy bolus" and "remote bolus" options...
CVE-2018-14781: Authentication Bypass by Capture-replay
Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...
PT-2018-1433
Name of the Vulnerable Software and Affected Versions Medtronic MMT 508 MiniMed insulin pump versions 508 through 751 Medtronic MMT 522 / MMT - 722 Paradigm REAL-TIME Medtronic MMT 523 / MMT - 723 Paradigm Revel Medtronic MMT 523K / MMT - 723K Paradigm Revel Medtronic MMT 551 / MMT - 751 MiniMed...
Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)
1. EXECUTIVE SUMMARY CVSS v3 5.3 Vendor: Medtronic --------- Begin Update A Part 1 of 3 -------- Equipment: Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers --------- End Update A Part 1 of 3 -------- Vulnerabilities: Cleartext Transmission of Sensitive Information, Authentication Bypass...