Lucene search
+L

647 matches found

CVE
CVE
•added 2019/04/11 1:59 p.m.•56 views

CVE-2019-3915

CVE-2019-3915 applies to Verizon Fios Quantum Gateway (G1100) firmware 02.01.00.05. The vulnerability is an authentication bypass via capture‑replay: because the web admin interface relies on HTTP (not HTTPS), an adjacent‑network attacker can intercept login requests and replay them to gain admin...

7.5CVSS7.7AI score0.00642EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/04/11 12:00 a.m.•7 views

CVE-2019-3915: Authentication Bypass by Capture-replay

Authentication Bypass by Capture-replay vulnerability in Verizon Fios Quantum Gateway G1100 firmware version 02.01.00.05 allows an unauthenticated attacker with adjacent network access to intercept and replay login requests to gain access to the administrative web interface...

7.5CVSS6.2AI score0.00642EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2019/04/11 12:00 a.m.•5 views

PT-2019-16770

Name of the Vulnerable Software and Affected Versions Verizon Fios Quantum Gateway G1100 version 02.01.00.05 Description The issue allows an unauthenticated attacker with adjacent network access to intercept and replay login requests, gaining access to the administrative web interface through an...

7.5CVSS0.00642EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/03/11 12:00 a.m.•8 views

CVE-2019-9659: Authentication Bypass by Capture-replay

The Chuango 433 MHz burglar-alarm product line uses static codes in the RF remote control, allowing an attacker to arm, disarm, or trigger the alarm remotely via replay attacks, as demonstrated by Chuango branded products, and non-Chuango branded products such as the Eminent EM8617 OV2 Wifi Alarm...

9.1CVSS5.9AI score0.0133EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/01/25 12:00 a.m.•7 views

CVE-2018-19023: Authentication Bypass by Capture-replay

Hetronic Nova-M prior to verson r161 uses fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state...

8.8CVSS5.9AI score0.00753EPSS
SaveExploits0References3
Schneier on Security
Schneier on Security
•added 2018/10/29 11:18 a.m.•35 views

Security Vulnerability in Internet-Connected Construction Cranes

This seems bad: The F25 software was found to contain a capture replay vulnerability -- basically an attacker would be able to eavesdrop on radio transmissions between the crane and the controller, and then send their own spoofed commands over the air to seize control of the crane. "These devices...

7.2AI score
SaveExploits0
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/10/24 12:00 a.m.•4 views

CVE-2018-17935: Authentication Bypass by Capture-replay

All versions of Telecrane F25 Series Radio Controls before 00.0A use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state...

8.1CVSS7.5AI score0.00663EPSS
SaveExploits0References3
ICS
ICS
•added 2018/10/23 12:00 a.m.•539 views

Telecrane F25 Series

1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Low skill level to exploit Vendor: Telecrane Equipment: F25 Series Vulnerability: Authentication Bypass by Capture-Replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthorized users to view commands, replay commands,...

8.1CVSS8.3AI score0.00663EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/09/18 12:00 a.m.•8 views

CVE-2018-17176: Authentication Bypass by Capture-replay

A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication always transmitted in cleartext can be replayed to /bin/webserver on port 8081. There are no nonces, and timestamps are not checked at all...

7.5CVSS7.2AI score0.01EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/29 12:00 a.m.•7 views

CVE-2018-7790: Authentication Bypass by Capture-replay

An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product all references, all versions prior to firmware V1.6.2.0. The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a...

9.8CVSS7.3AI score0.02478EPSS
SaveExploits0References6
Cvelist
Cvelist
•added 2018/08/13 10:00 p.m.•41 views

CVE-2018-14781 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.3AI score0.00712EPSS
SaveExploits0References3
CVE
CVE
•added 2018/08/13 10:00 p.m.•84 views

CVE-2018-14781

CVE-2018-14781 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps (e.g., MMT-508, MMT-511/512/712, MMT-515/723, MMT-522/723 REAL-TIME, MMT-551/751, etc.). Root cause: Authentication Bypass by Capture-replay when paired with a remote controller with non-default easy bol...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3Affected Software1
NVD
NVD
•added 2018/08/13 9:48 p.m.•34 views

CVE-2018-14781

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3
Prion
Prion
•added 2018/08/13 9:48 p.m.•28 views

Default configuration

Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the "easy bolus" and "remote bolus" options...

2.9CVSS5.2AI score0.00712EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/08/13 12:00 a.m.•7 views

CVE-2018-14781: Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS6.3AI score0.00712EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2018/08/07 12:00 a.m.•7 views

PT-2018-1433

Name of the Vulnerable Software and Affected Versions Medtronic MMT 508 MiniMed insulin pump versions 508 through 751 Medtronic MMT 522 / MMT - 722 Paradigm REAL-TIME Medtronic MMT 523 / MMT - 723 Paradigm Revel Medtronic MMT 523K / MMT - 723K Paradigm Revel Medtronic MMT 551 / MMT - 751 MiniMed...

6.1CVSS0.00712EPSS
SaveExploits0References6
ICS
ICS
•added 2018/08/07 12:00 a.m.•60 views

Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.3 Vendor: Medtronic --------- Begin Update A Part 1 of 3 -------- Equipment: Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers --------- End Update A Part 1 of 3 -------- Vulnerabilities: Cleartext Transmission of Sensitive Information, Authentication Bypass...

5.9AI score
SaveExploits0References5
NVD
NVD
•added 2018/03/14 7:29 p.m.•32 views

CVE-2018-2402

In systems using the optional capture & replay functionality of SAP HANA, 1.00 and 2.00, see SAP Note 2362820 for more information about capture & replay, user credentials may be stored in clear text in the indexserver trace files of the control system. An attacker with the required authorization...

8.4CVSS7.8AI score0.01492EPSS
SaveExploits0References3
CVE
CVE
•added 2018/03/14 7:00 p.m.•72 views

CVE-2018-2402

SAP HANA vulnerability CVE-2018-2402 affects the optional capture & replay feature in SAP HANA versions 1.00 and 2.00. The root cause is that user credentials can be stored in plaintext in the control system’s indexserver trace files, enabling an attacker with required authorizations on the contr...

8.4CVSS8.2AI score0.01492EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
•added 2018/03/14 7:00 p.m.•38 views

CVE-2018-2402

In systems using the optional capture & replay functionality of SAP HANA, 1.00 and 2.00, see SAP Note 2362820 for more information about capture & replay, user credentials may be stored in clear text in the indexserver trace files of the control system. An attacker with the required authorization...

7.6CVSS8.3AI score0.01492EPSS
SaveExploits0References3
Rows per page