Lucene search
+L

209 matches found

Cvelist
Cvelist
added 2020/06/29 1:45 p.m.29 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

3.8AI score0.00333EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:43 p.m.58 views

CVE-2020-12041

The Baxter Spectrum Wireless Battery Module (WBM) telnet CLI vulnerability CVE-2020-12041 affects Baxter Spectrum WBM components (v17, v20D29–D32, v22D24). The Telnet interface grants access to sensitive data and permits temporary changes to network settings, including rebooting the WBM, with cha...

9.4CVSS9.1AI score0.01395EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:43 p.m.34 views

CVE-2020-12041

The Baxter Spectrum WBM v17, v20D29, v20D30, v20D31, and v22D24 telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to netwo...

9.2AI score0.01395EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:43 p.m.56 views

CVE-2020-12045

CVE-2020-12045 affects Baxter Spectrum WBM when used with Baxter Spectrum v8.x; the WBM runs a Telnet service on port 1023 with hard-coded credentials. Connected sources document a Telnet exposure tied to WBM/Spectrum configurations and assign high/severe CVSS values (up to 9.8) for this vulnerab...

9.8CVSS9.4AI score0.01662EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:43 p.m.33 views

CVE-2020-12045

The Baxter Spectrum WBM v17, v20D29, v20D30, v20D31, and v22D24 when used in conjunction with a Baxter Spectrum v8.x model 35700BAX2, operates a Telnet service on Port 1023 with hard-coded credentials...

9.5AI score0.01662EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:41 p.m.27 views

CVE-2020-12043

The Baxter Spectrum WBM v17, v20D29, v20D30, v20D31, and v22D24 when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted...

9.6AI score0.02081EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:41 p.m.54 views

CVE-2020-12043

CVE-2020-12043 affects Baxter Spectrum WBM wireless configurations (versions v17, v20D29–D32, v22D24). The FTP service on the WBM remains accessible until the unit is rebooted, due to an operation on a resource after expiration/release. NVD lists CVSSv3.1 base score 9.8; ICS advisory notes CVSSv3...

9.8CVSS9.5AI score0.02081EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/06/29 1:41 p.m.64 views

CVE-2020-12047

CVE-2020-12047 affects Baxter Spectrum WBM when used with Spectrum v8.x (model 35700BAX2) in factory-default wireless config; the WBM enables an FTP service with hard-coded credentials (versions v17, v20D29–v20D32, v22D24). Root cause: hard-coded credentials enabling FTP access. Impact per source...

9.8CVSS9.4AI score0.01662EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:41 p.m.37 views

CVE-2020-12047

The Baxter Spectrum WBM v17, v20D29, v20D30, v20D31, and v22D24, when used with a Baxter Spectrum v8.x model 35700BAX2 in a factory-default wireless configuration enables an FTP service with hard-coded credentials...

9.5AI score0.01662EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.16 views

Baxter ExactaMix EM2400 and ExactaMix EM1200 Trust Management Issues Vulnerability (CNVD-2021-21074)

The Baxter ExactaMix EM2400 and ExactaMix EM1200 are both automated drug mixing systems from Baxter. A trust management issue vulnerability exists in the Baxter ExactaMix EM2400 and ExactaMix EM1200, which stems from the ExactaMix application's use of hard-coded administrative account credentials...

6.1CVSS6.5AI score0.00345EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.4 views

Baxter PrismaFlex Hardcoding Vulnerability

The Baxter PrismaFlex is a critical care device from Baxter. A hard-coded vulnerability exists in Baxter PrismaFlex all versions that stems from the fact that PrismaFlex contains a hard-coded service password that can be exploited by an attacker to modify device settings and calibration values...

7.5CVSS7.1AI score0.00483EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.27 views

Unspecified Vulnerability in Baxter Sigma Spectrum Infusion System and Baxter Spectrum Infusion System

The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A security vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x model 35700BAX2,...

9.8CVSS6.6AI score0.0094EPSS
SaveExploits1References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.5 views

Baxter PrismaFlex and PrismMax Trust Management Issues Vulnerabilities

The Baxter PrismaFlex and PrismMax are both critical care devices from Baxter, Inc. A trust management issue vulnerability exists in Baxter PrismaFlex all versions and PrismMax prior to version 3.x. The vulnerability stems from a lack of authentication on the device and can be exploited by an...

4.9CVSS7.1AI score0.00247EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.14 views

Baxter Spectrum WBM Trust Management Issues Vulnerability (CNVD-2021-21077)

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum is vulnerable to a trust management issue that could be exploited by an attacke...

9.8CVSS6.7AI score0.01662EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.4 views

Baxter PrismaFlex and PrismMax Information Disclosure Vulnerabilities

The Baxter PrismaFlex and PrismMax are both critical care devices from Baxter. An information disclosure vulnerability exists in Baxter PrismaFlex all versions and PrismMax prior to version 3.x. The vulnerability stems from the failure of an affected device to encrypt e.g., TLS/SSL transmitted da...

7.5CVSS6.2AI score0.00496EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.13 views

Unspecified Vulnerability in Baxter Spectrum WBM (CNVD-2021-21076)

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. A security vulnerability exists in the Baxter Spectrum WBM that can be exploited by an attacker to gain access to F...

9.8CVSS7.1AI score0.02081EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.15 views

Unspecified Vulnerability in Baxter Spectrum WBM

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability. An attacker could exploit this vulnerability to...

9.4CVSS6.8AI score0.01395EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.15 views

Baxter Phoenix Hemodialysis Delivery System Information Disclosure Vulnerability

The Baxter Phoenix Hemodialysis Delivery System is a hemodialysis device from Baxter. An information disclosure vulnerability exists in the Baxter Phoenix Hemodialysis Delivery System SW version 3.36 and 3.40, which arises from an unsupported encryption of transmitted data during the transfer of...

7.5CVSS6.3AI score0.00452EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.12 views

Baxter Spectrum WBM Trust Management Issues Vulnerability

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability that can be exploited by an attacker to run Telnet...

9.8CVSS6.9AI score0.01662EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:0 a.m.14 views

Baxter ExactaMix EM2400 and ExactaMix EM1200 Trust Management Issues Vulnerability

The Baxter ExactaMix EM2400 and ExactaMix EM1200 are both automated drug mixing systems from Baxter. A trust management issue vulnerability exists in the Baxter ExactaMix EM2400 and ExactaMix EM1200, which stems from hard-coded credentials used in the admin account of the ExactaMix operating...

10CVSS6.8AI score0.01856EPSS
SaveExploits0References1
Rows per page
Query Builder