Prion
Prion
added 2020/06/29 2:15 p.m.17 views

Hardcoded credentials

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings...

3.6CVSS5.8AI score0.00247EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:54 p.m.31 views

CVE-2020-12012

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials f...

6.2AI score0.00345EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:54 p.m.60 views

CVE-2020-12012

CVE-2020-12012 affects Baxter ExactaMix EM2400 and EM1200 systems (versions listed in connected documents). The root cause is hard-coded administrative credentials in the ExactaMix application, enabling an attacker with physical access to view/update system configuration and data, potentially exp...

6.1CVSS6.2AI score0.00345EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/06/29 1:54 p.m.61 views

CVE-2020-12016

CVE-2020-12016 affects Baxter ExactaMix EM2400 (versions 1.10, 1.11, 1.13, 1.14) and EM1200 (versions 1.1, 1.2, 1.4, 1.5). The root cause is hard-coded administrative credentials in the ExactaMix operating system, enabling an attacker with network access to gain unauthorized system access and pot...

10CVSS9.3AI score0.01856EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:54 p.m.25 views

CVE-2020-12016

Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account...

9.4AI score0.01856EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:53 p.m.23 views

CVE-2020-12008

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI...

7.3AI score0.00948EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:53 p.m.52 views

CVE-2020-12008

CVE-2020-12008 affects Baxter ExactaMix EM 2400 (versions 1.10, 1.11) and ExactaMix EM1200 (versions 1.1, 1.2), where cleartext transmission of order information can expose PHI over the network. The connected Red Hat and ICS advisories corroborate the issue as a cleartext data exposure vulnerabil...

7.5CVSS7.2AI score0.00948EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/06/29 1:53 p.m.60 views

CVE-2020-12032

CVE-2020-12032 concerns Baxter ExactaMix EM 2400 (versions 1.10–1.11 and 1.13–1.14 per ICS update) and ExactaMix EM1200 (versions 1.1–1.2, 1.4–1.5 per ICS advisory) where device data is stored in an unencrypted database, enabling a network-attacker to view or modify sensitive data including PHI. ...

9.1CVSS8.7AI score0.00941EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:53 p.m.30 views

CVE-2020-12032

Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database. This could allow an attacker with network access to view or modify sensitive data including PHI...

8.9AI score0.00941EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:51 p.m.50 views

CVE-2020-12020

CVE-2020-12020 affects Baxter ExactaMix EM 2400 (versions 1.10, 1.11, 1.13) and ExactaMix EM1200 (versions 1.1, 1.2, 1.4). The Red Hat and ICS advisories describe an improper access control flaw that allows non-administrative users to access the operating system and edit the application startup s...

6.1CVSS6.2AI score0.00313EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:51 p.m.29 views

CVE-2020-12020

Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining access to the operating system and editing the application startup script. Successful exploitation of this vulnerability may allow an...

6.3AI score0.00313EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:51 p.m.30 views

CVE-2020-12024

Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to th...

6AI score0.00345EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:51 p.m.67 views

CVE-2020-12024

CVE-2020-12024 affects Baxter ExactaMix EM2400 (versions 1.10, 1.11, 1.13, 1.14) and ExactaMix EM1200 (versions 1.1, 1.2, 1.4, 1.5). Root cause: inadequate restriction of USB interface access by unauthorized users with physical access, enabling loading of unauthorized payloads or direct hard driv...

6.1CVSS5.9AI score0.00345EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.35 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00496EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:49 p.m.52 views

CVE-2020-12036

CVE-2020-12036 affects Baxter PrismaFlex (all versions) and PrisMax (all versions prior to 3.x). The root cause is lack of data-in-transit encryption (no TLS/SSL) when these devices send treatment data to a PDMS or EMR, enabling an attacker with network access to observe sensitive data. The ICS a...

7.5CVSS7.4AI score0.00496EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.28 views

CVE-2020-12035

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings...

5.1AI score0.00247EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:49 p.m.60 views

CVE-2020-12035

CVE-2020-12035 affects Baxter PrismaFlex (all versions) and PrisMax (all versions prior to 3.x). Root cause is a hard-coded service password that grants access to biomedical information, device settings, calibration settings, and network configuration, enabling an attacker to modify device settin...

4.9CVSS5.1AI score0.00247EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2020/06/29 1:49 p.m.57 views

CVE-2020-12037

CVE-2020-12037 affects Baxter PrismaFlex (all versions) and PrisMax (all versions before 3.x). The root cause is a hard-coded service password (CWE-259), enabling an attacker to access device settings, calibration data, and network configuration. The ICS update also notes lack of data-in-transit ...

7.5CVSS7.4AI score0.00483EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.24 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00483EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:45 p.m.64 views

CVE-2020-12039

CVE-2020-12039 affects Baxter Sigma Spectrum Infusion System v6.x (35700BAX) and v8.x (35700BAX2); hard-coded passwords entered via keypad grant access to biomedical menus, including device settings, calibration values, and WBM network configuration. This is a local/physical-access issue with pub...

2.4CVSS4.1AI score0.00333EPSS