5252 matches found
CVE-2020-25164 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface...
CVE-2020-25166 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper...
CVE-2020-25166 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper...
CVE-2020-25166
CVE-2020-25166 concerns an improper verification of the cryptographic signature for firmware updates in B. Braun SpaceCom devices (SpaceCom, Battery Pack with Wi‑Fi) and Data module compactplus (versions L81/U61 and A10/A11). The root cause is signature verification weakness, allowing attackers t...
CVE-2020-25154 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites...
CVE-2020-25154
CVE-2020-25154 is an open redirect vulnerability in the B. Braun Melsungen AG SpaceCom family (SpaceCom SpaceStation, Battery Pack with Wi‑Fi) and the Data module compactplus (A10/A11). The ICS advisory (ICSMA-20-296-02) confirms a remote, unauthenticated open redirect in the administrative inter...
CVE-2020-25154 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites...
CVE-2020-25162 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges...
CVE-2020-25162
CVE-2020-25162 is an XPath injection vulnerability affecting B. Braun SpaceCom, Battery Pack SP with Wi‑Fi, and Data module compactplus. Affected software: SpaceCom/L81 (and U61) and Data module compactplus/A10–A11 (non‑US distribution). Root cause per the advisory: improper handling of XPath exp...
CVE-2020-25162 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges...
CVE-2020-25158
CVE-2020-25158 is a reflected XSS vulnerability affecting B. Braun SpaceCom, Battery Pack with Wi‑Fi, and Data module compactplus (SpaceCom v L81/U61 and earlier; compactplus A10/A11). The ICS advisory details multiple related issues (XSS and other CVEs) and confirms impact when these components ...
CVE-2020-25158 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A reflected cross-site scripting XSS vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations...
CVE-2020-25158 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A reflected cross-site scripting XSS vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations...
CVE-2020-25160 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration...
CVE-2020-25160 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration...
CVE-2020-25152 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges...
CVE-2020-25160
CVE-2020-25160 involves improper access controls in B. Braun SpaceCom (versions L81/U61 and earlier), Battery Pack with Wi‑Fi (U61/L81 and earlier), and Data module compactplus (A10/A11). The root cause is improper access control that allows attackers to extract and tamper with the devices’ netwo...
CVE-2020-25152 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A session fixation vulnerability in the B. Braun Melsungen AG SpaceCom administrative interface Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to hijack web sessions and escalate privileges...
CVE-2020-25152
CVE-2020-25152 is a session fixation vulnerability in B. Braun SpaceCom administrative interface and the Data module compactplus. Affected: SpaceCom software versions L81/U61 and earlier (outside US) and SpaceCom 2; Data module compactplus versions A10 and A11. Root cause: session fixation that c...
CVE-2020-16238 B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with command line access to the underlying Linux system to escalate privileges to the root user...