5252 matches found
GeniXCMS Cross-site Scripting (XSS)
GeniXCMS 1.0.2 has XSS triggered by an authenticated user who submits a page, as demonstrated by a crafted oncut attribute in a B element...
CVE-2021-22275
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service...
Buffer overflow
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service...
CVE-2021-22275
CVE-2021-22275 describes a Buffer Overflow in the B&R Automation Runtime webserver that can be triggered by an unauthenticated, network-based attacker to stop the device’s cyclic program and cause a denial of service. Documents associated with this CVE indicate the vulnerability arises from impro...
B&R Automation Runtime 安全漏洞
B&R Automation Runtime is a major component of AS from B&R Automation, an Austrian company. A security vulnerability exists in B&R Automation Runtime versions prior to 4.91 that stems from improper buffer limits in the web server. Exploitation of the vulnerability by an unauthenticated attacker...
Siemens Teamcenter
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Teamcenter Vulnerabilities: Stack-based Buffer Overflow, Improper Restriction of XML External Entity Reference 2. UPDATE INFORMATION This updated advisory is a follow-up to the...
CVE-2022-27188
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute ...
CVE-2022-27188
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute ...
Command injection
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute ...
Authentication flaw
Improper authentication vulnerability in the communication protocol provided by AD Automation Design server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP Small R6.01.10 to R6.09.00, CENTUM VP Basic R6.01.10 to R6.09.00, and B/M9000 VP R8.01.01 to R8.03.01 allows an attacker to use the functions...
CVE-2022-27188
CVE-2022-27188 is a local OS command injection in Yokogawa CENTUM VP family. A local attacker who can access the affected machine could modify a file generated by Graphic Builder to execute arbitrary OS commands. Affected: CENTUM VP variants R4.01.00–R4.03.00, CENTUM VP Small/BASIC (same ranges),...
CVE-2022-27188
OS command injection vulnerability exists in CENTUM VP R4.01.00 to R4.03.00, CENTUM VP Small R4.01.00 to R4.03.00, CENTUM VP Basic R4.01.00 to R4.03.00, and B/M9000 VP R6.01.01 to R6.03.02, which may allow an attacker who can access the computer where the affected product is installed to execute ...
CVE-2022-26034
The CVE-2022-26034 issue affects Yokogawa CENTUM VP family and B/M9000 VP (notably CENTUM VP R6.01.10–R6.09.00; B/M9000 VP R8.01.01–R8.03.01; and ProSafe-RS up to R4.07.00 if RS4E5000 is installed). The root cause is improper authentication in the AD server’s communication protocol, enabling an a...
CVE-2022-26034
Improper authentication vulnerability in the communication protocol provided by AD Automation Design server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP Small R6.01.10 to R6.09.00, CENTUM VP Basic R6.01.10 to R6.09.00, and B/M9000 VP R8.01.01 to R8.03.01 allows an attacker to use the functions...
CVE-2020-25166
An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper...
CVE-2020-25158
A reflected cross-site scripting XSS vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations...
CVE-2020-25162
A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges...
CVE-2020-25160
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration...
CVE-2020-25156
Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root...
CVE-2020-25164
A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface...