1100 matches found
CVE-2021-40170
An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...
CVE-2021-40170
An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...
CVE-2021-40171
The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...
CVE-2021-40170
An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...
CVE-2021-40170
The CVE-2021-40170 entry describes an RF replay attack in the SecuritasHome Startpaket (HPGW-G 0.0.2.23F BG_U-ITR-F1-BD_BL.A30.20181117). The vulnerability allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals, including disarming an armed system. A...
CVE-2021-40170
An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...
CVE-2021-40171
The CVE-2021-40171 entry concerns the SecuritasHome Startpaket (HPGW-G 0.0.2.23F BG_U-ITR-F1-BD_BL.A30.20181117). Reported vulnerability: absence of notifications for ongoing RF jamming attacks, which can allow an attacker to block legitimate traffic without alerting the system owner. Public sour...
CVE-2021-40171
The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...
PT-2021-22828
Name of the Vulnerable Software and Affected Versions SecuritasHome home alarm system version HPGW-G 0.0.2.23F BG U-ITR-F1-BD BL.A30.20181117 Description The issue allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals, enabling an adversary to disar...
PT-2021-23992
Name of the Vulnerable Software and Affected Versions: WECON LeviStudioU versions 2019-09-21 and prior Description: The issue concerns multiple stack-based buffer overflow instances while parsing project files, which may allow an attacker to execute arbitrary code. This occurs in various tags,...
Yokogawa Software Access Control
The vulnerability of Yokogawa’s software products is related to deficiencies in access control. Exploiting this vulnerability can allow attackers to generate false system or technological alarm signals, or block existing alarm signals...
ECOA Building Automation System Cookie Poisoning / Authentication Bypass Vulnerabilities
ECOA building automation systems suffer from a cookie poisoning vulnerability that allows for authentication bypass. Many versions are affected. ECOA Building Automation System Cookie Poisoning Authentication Bypass Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected...
ECOA Building Automation System Directory Traversal Content Disclosure
Summary 1 The Risk-Terminator Web Graphic control BEMS Building Energy Management System are designed to provide you with the latest in the Human Machine Interface HMI technology, for completely monitoring and controlling management. It may be used singly for small and medium sized facilities,...
CVE-2021-38393
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query....
Delta Electronics DIAEnergie SQL注入漏洞
A SQL blind injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint in DIAEnergie 1.7.5 and earlier versions. The vulnerability stems from the application not properly validating the value provided by the user via the parameter agid before using the value as part of a S...
Security update for MozillaThunderbird (important)
openSUSE Security Update: Security update for MozillaThunderbird Announcement ID: openSUSE-SU-2021:1091-1 Rating: important References: 1188275 Cross-References: CVE-2021-29969 CVE-2021-29970 CVE-2021-29976 CVE-2021-30547 CVSS scores: CVE-2021-29969 SUSE: 7.5...
Security update for MozillaThunderbird (important)
openSUSE Security Update: Security update for MozillaThunderbird Announcement ID: openSUSE-SU-2021:2458-1 Rating: important References: 1188275 Cross-References: CVE-2021-29969 CVE-2021-29970 CVE-2021-29976 CVE-2021-30547 CVSS scores: CVE-2021-29969 SUSE: 7.5...
CVE-2020-22650
A memory leak vulnerability in sim-organizer.c of AlienVault Ossim v5 causes a denial of service DOS via a system crash triggered by the occurrence of a large number of alarm events...
CVE-2020-22650
A memory leak vulnerability in sim-organizer.c of AlienVault Ossim v5 causes a denial of service DOS via a system crash triggered by the occurrence of a large number of alarm events...
UBUNTU-CVE-2020-22650