Lucene search
K

888 matches found

Nuclei
Nuclei
added 16 hours ago30 views

CentralSquare CryWolf - Path Traversal

A traversal vulnerability in GeneralDocs.aspx in CentralSquare CryWolf False Alarm Management through 2024-08-09 allows unauthenticated attackers to read files outside of the working web directory via the rpt parameter, leading to the disclosure of sensitive information. id: CVE-2024-45241 info:...

7.5CVSS7.7AI score0.90825EPSS
Exploits1References3
RedhatCVE
RedhatCVE
added yesterday7 views

CVE-2026-6242

An authenticated format string vulnerability exists in the ONVIF Subscribe service in Tapo C520WS v2 due to improper handling of externally supplied parameters within formatting functions. An attacker may inject crafted format strings into event subscription requests or notification generation pa...

6.8CVSS5.5AI score0.00014EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 3 days ago4 views

CVE-2026-40849

An low privileged remote attacker can exploit an unauthenticated SQL Injection vulnerability in the useralarmprofile view due to improper neutralization of special elements in a SQL SELECT command. This can result in a total loss of confidentiality...

7.1CVSS5.8AI score0.00039EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 3 days ago6 views

CVE-2026-40816

An unauthenticated remote attacker can exploit an unauthenticated SQL Injection vulnerability in the mb24alarm.php files mb24configetTagAlarm function due to improper neutralization of special elements in a SQL SELECT command. This can result in a total loss of confidentiality...

8.7CVSS5.8AI score0.00064EPSS
Exploits0References1
Positive Technologies
Positive Technologies
added 3 days ago10 views

PT-2026-47079

An authenticated format string vulnerability exists in the ONVIF Subscribe service in Tapo C520WS v2 due to improper handling of externally supplied parameters within formatting functions. An attacker may inject crafted format strings into event subscription requests or notification generation pa...

6.8CVSS5.5AI score0.00014EPSS
Exploits0References4
EUVD
EUVD
added 5 days ago7 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References3
NVD
NVD
added 6 days ago10 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.00045EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 6 days ago4 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References2
CVE
CVE
added 6 days ago11 views

CVE-2022-4992

CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References2
Cvelist
Cvelist
added 6 days ago27 views

CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.00045EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 6 days ago7 views

CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 6 days ago5 views

CVE-2019-25724

Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References4
CVE
CVE
added 6 days ago12 views

CVE-2019-25724

The CVE-2019-25724 entry describes a network-based Denial of Service impacting Dräger Infinity M300 patient-worn monitors running VG2.x and earlier. The underlying issue allows an attacker with access to the hospital network or Infinity Network to repeatedly trigger device reboots, driving the de...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
NVD
NVD
added 6 days ago8 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS0.00017EPSS
Exploits0References2
CVE
CVE
added 6 days ago11 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 monitors running VG4.1.1, VG4.0.3, and lower are affected by network message handling vulnerabilities. The issue allows network-adjacent attackers to spoof or tamper with data and to cause denial-of-service conditions. If an attacker ...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References2
EUVD
EUVD
added 6 days ago6 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References2
Cvelist
Cvelist
added 6 days ago31 views

CVE-2019-25719 Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS0.00017EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 6 days ago6 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References4
OSV
OSV
added 6 days ago7 views

SUSE-SU-2026:21983-1 Security update for the Linux Kernel (Live Patch 0 for SUSE Linux Enterprise 16)

This update for the SUSE Linux Enterprise Kernel 6.12.0-160000.5.1 fixes various security issues The following security issues were fixed: - CVE-2025-54518: AMD-SN-7052: CPU OP Cache Corruption bsc1264096. - CVE-2026-23243: RDMA/umad: Reject negative datalen in ibumadwrite bsc1259798. -...

7.8CVSS6AI score0.00254EPSS
Exploits12References13
Positive Technologies
Positive Technologies
added 6 days ago10 views

PT-2026-45862

Name of the Vulnerable Software and Affected Versions Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions prior to VG4.2 Description A network message handling issue allows remote attackers to inject spoofed or tampered data. This can lead to denial-of-service...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References4
Rows per page
Query Builder