941 matches found
CVE-2023-26061
An issue was discovered in Nokia NetAct before 22 FP2211. On the Scheduled Search tab under the Alarm Reports Dashboard page, users can create a script to inject XSS. Input validation was missing during creation of a scheduled task. For an external attacker, it is very difficult to exploit this,...
CVE-2023-50128
The remote keyless system of the Hozard alarm system alarmsystemen v1.0 sends an identical radio frequency signal for each request, which results in an attacker being able to conduct replay attacks to bring the alarm system to a disarmed state...
CVE-2023-50125
A default engineer password set on the Hozard alarm system Alarmsysteem v1.0 allows an attacker to bring the alarm system to a disarmed state...
CVE-2023-31763
Weak security in the transmitter of AGShome Smart Alarm v1.0 allows attackers to gain full access to the system via a code replay attack...
CVE-2023-26942
Weak encryption mechanisms in RFID Tags in Yale IA-210 Alarm v1.0 allows attackers to create a cloned tag via physical proximity to the original...
CVE-2023-1751
The listed versions of Nexx Smart Home devices use a WebSocket server that does not validate if the bearer token in the Authorization header belongs to the device attempting to associate. This could allow any authorized user to receive alarm information and signals meant for other devices which...
CVE-2023-1752
The listed versions of Nexx Smart Home devices could allow any user to register an already registered alarm or associated device with only the device’s MAC address...
CVE-2023-1256
The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states...
CVE-2022-45462
Alarm instance management has command injection when there is a specific command configured. It is only for logged-in users. We recommend you upgrade to version 2.0.6 or higher...
CVE-2022-20414
In setImpl of AlarmManagerService.java, there is a possible way to put a device into a boot loop due to an uncaught exception. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions:...
CVE-2022-20307
In AlarmManagerService, there is a possible way to determine whether an app is installed, without query permissions, due to side channel information disclosure. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for...
CVE-2021-40171
The absence of notifications regarding an ongoing RF jamming attack in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to block legitimate traffic while not alerting the owner of the system...
CVE-2021-40170
An RF replay attack vulnerability in the SecuritasHome home alarm system, version HPGW-G 0.0.2.23F BGU-ITR-F1-BDBL.A30.20181117, allows an attacker to trigger arbitrary system functionality by replaying previously recorded signals. This lets an adversary, among other things, disarm an armed syste...
CVE-2021-26281
Some parameters of the alarm clock module are improperly stored, leaking some sensitive information...
CVE-2020-28973
The ABUS Secvest wireless alarm system FUAA50000 v3.01.17 fails to properly authenticate some requests to its built-in HTTPS interface. Someone can use this vulnerability to obtain sensitive information from the system, such as usernames and passwords. This information can then be used to...
CVE-2020-22650
A memory leak vulnerability in sim-organizer.c of AlienVault Ossim v5 causes a denial of service DOS via a system crash triggered by the occurrence of a large number of alarm events...
CVE-2020-13425
TrackR devices through 2020-05-06 allow attackers to trigger the Beep aka alarm feature, which will eventually cause a denial of service when battery capacity is exhausted...
CVE-2020-27030
In onCreate of HandleApiCalls.java, there is a possible permission bypass due to a confused deputy. This could lead to local escalation of privilege that allows an app to set or dismiss the alarm with no additional execution privileges needed. User interaction is not needed for...
CVE-2019-14261
An issue was discovered on ABUS Secvest FUAA50000 3.01.01 devices. Due to an insufficient implementation of jamming detection, an attacker is able to suppress correctly received RF messages sent between wireless peripheral components, e.g., wireless detectors or remote controls, and the ABUS...
CVE-2019-5213
Honor play smartphones with versions earlier than Cornell-AL00A 9.1.0.321C00E320R1P1T8 have an insufficient authentication vulnerability. The system has a logic judge error under certain scenario. Successful exploit could allow the attacker to modify the alarm clock settings after a serious of...