1201 matches found
CVE-2023-24502 Electra Central AC unit – Easily calculated password
Electra Central AC unit – The unit opens an AP with an easily calculated password...
CVE-2023-24501 Electra Central AC unit – Hardcoded Credentials
Electra Central AC unit – Hardcoded Credentials in unspecified code used by the unit...
CVE-2023-24502
The CVE-2023-24502 entry concerns Electra Central AC unit where the device opens an access point secured by an easily calculated password. The connected sources confirm this weakness, but do not provide concrete exploit vectors, affected firmware versions, or remediation details. Some entries not...
PT-2023-19649 · Electra · Electra Central Ac Unit
Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue concerns an Electra Central AC unit that opens an Access Point AP with a password that can be easily calculated. Recommendations: At the moment, there is no...
CVE-2023-24500 Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
CVE-2023-24503 Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
CVE-2023-24501
CVE-2023-24501 affects the Electra Central AC unit, where hardcoded credentials are present in unspecified code used by the unit. The security impact is high across confidentiality, integrity, and availability, with a network attack surface and no user interaction required. The available document...
PT-2023-19648 · Electra · Electra Central Ac Unit
Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue concerns hardcoded credentials in unspecified code used by the Electra Central AC unit. There is no information provided about the estimated number of potentially...
CVE-2023-24503 Electra Smart Kit for Split AC – Adjacent attacker may cause the unit to load unauthorized FW
Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...
PT-2023-19650 · Electra · Electra Central Ac Unit
Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue allows an adjacent attacker to cause the unit to load unauthorized firmware. Recommendations: At the moment, there is no information about a newer version that...
PT-2023-19651 · Electra · Electra Central Ac Unit
Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue allows an adjacent attacker to cause the unit to connect to an unauthorized update server. Recommendations: At the moment, there is no information about a newer...
CVE-2023-24504 Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server
Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server...
PT-2023-19647 · Electra · Electra Central Ac Unit
Name of the Vulnerable Software and Affected Versions: Electra Central AC unit affected versions not specified Description: The issue allows an adjacent attacker to cause the unit to load unauthorized firmware. Recommendations: At the moment, there is no information about a newer version that...
CVE-2023-24503
The CVE-2023-24503 entry concerns the Electra Central AC unit (Electra Smart Kit for Split AC). The connected records describe an adjacent- attacker capability to cause the unit to load unauthorized firmware, indicating the vulnerable component/process is tied to firmware loading mechanisms. Spec...
PT-2023-20898 · Tenda · Tenda Ac10
Name of the Vulnerable Software and Affected Versions: Tenda AC10 version US AC10V4.0si V16.03.10.13 cn Description: The issue is related to a stack overflow via the sub 4A75C0 function, allowing attackers to cause a Denial of Service DoS or execute arbitrary code via a crafted payload...
ABB OPC Server for Incorrect Permission Assignment for Critical Resource (CVE-2021-22284)
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
ABB 800xA Improper Input Validation (CVE-2021-22277)
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service. This plugin only works with Tenable.ot. Please visit...
CVE-2023-24098
TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formSysLog. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects products...
CVE-2023-24095
TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formSystemCheck. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects...
CVE-2023-24097
TrendNet Wireless AC Easy-Upgrader TEW-820AP v1.0R, firmware version 1.01.B01 was discovered to contain a stack overflow via the submit-url parameter at /formPasswordAuth. This vulnerability allows attackers to execute arbitrary code via a crafted payload. NOTE: This vulnerability only affects...