Lucene search
+L

1201 matches found

wpexploit
wpexploit
added 2023/04/20 12:0 a.m.161 views

ActiveCampaign < 8.1.12 - Contributor+ Stored XSS

The plugin does not validate and escape some of its block options before outputting them back in a page/post where the block is embed, which could allow users with the contributor role and above to perform Stored Cross-Site Scripting attacks As a contributor, add a "AC Forms" Gutenberg block to a...

5.4CVSS7.8AI score0.00462EPSS
SaveExploits2
NVD
NVD
added 2023/04/17 10:15 p.m.16 views

CVE-2023-24501

Electra Central AC unit – Hardcoded Credentials in unspecified code used by the unit...

9.8CVSS9.6AI score0.00621EPSS
SaveExploits0References1
NVD
NVD
added 2023/04/17 10:15 p.m.21 views

CVE-2023-24502

Electra Central AC unit – The unit opens an AP with an easily calculated password...

7.5CVSS7.6AI score0.00171EPSS
SaveExploits0References1
NVD
NVD
added 2023/04/17 10:15 p.m.20 views

CVE-2023-24500

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

7.5CVSS7.5AI score0.00177EPSS
SaveExploits0References1
OSV
OSV
added 2023/04/17 10:15 p.m.4 views

CVE-2023-24504

Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server...

6.5CVSS6.6AI score0.00271EPSS
SaveExploits0References1
NVD
NVD
added 2023/04/17 10:15 p.m.18 views

CVE-2023-24503

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

7.5CVSS7.5AI score0.00177EPSS
SaveExploits0References1
Prion
Prion
added 2023/04/17 10:15 p.m.14 views

Code injection

Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server...

3.3CVSS6.4AI score0.00271EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2023/04/17 10:15 p.m.16 views

Hardcoded credentials

Electra Central AC unit – Hardcoded Credentials in unspecified code used by the unit...

7.5CVSS9.4AI score0.00621EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2023/04/17 10:15 p.m.13 views

Code injection

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

3.3CVSS6.4AI score0.00177EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2023/04/17 10:15 p.m.19 views

Path traversal

Electra Central AC unit – The unit opens an AP with an easily calculated password...

3.3CVSS6.5AI score0.00171EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2023/04/17 10:15 p.m.15 views

Code injection

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

3.3CVSS6.4AI score0.00177EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2023/04/17 12:0 a.m.7 views

Electra Central AC unit 安全漏洞

The Electra Central AC unit is an Electra Central AC unit from Electra. A security vulnerability exists in the Electra Central AC unit. An attacker could exploit the vulnerability to cause unauthorized firmware to be loaded...

7.5CVSS6.5AI score0.00177EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
added 2023/04/17 12:0 a.m.7 views

CVE-2023-24500 Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW

Electra Central AC unit – Adjacent attacker may cause the unit to load unauthorized FW...

7.5CVSS6.8AI score0.00177EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2023/04/17 12:0 a.m.29 views

CVE-2023-24502 Electra Central AC unit – Easily calculated password

Electra Central AC unit – The unit opens an AP with an easily calculated password...

7.5CVSS7.8AI score0.00171EPSS
SaveExploits0References1
CVE
CVE
added 2023/04/17 12:0 a.m.41 views

CVE-2023-24504

The CVE-2023-24504 entry concerns Electra Central AC units. Reported vulnerability: an adjacent attacker could cause the unit to connect to an unauthorized update server. Public sources corroborate an impact on update server trust and potential control over update behavior; however, the documents...

7.5CVSS6.6AI score0.00271EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2023/04/17 12:0 a.m.40 views

CVE-2023-24500

The CVE-2023-24500 entry concerns the Electra Central AC unit. Affected component/area: the unit’s firmware loading process (firmware loading capability). Root cause: adjacent access enables loading of unauthorized firmware, as described in the vulnerability note. Impact: confidentiality and inte...

7.5CVSS6.6AI score0.00177EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2023/04/17 12:0 a.m.6 views

Electra Central AC unit 安全漏洞

The Electra Central AC unit is an Electra Central AC unit from Electra. A security vulnerability exists in the Electra Central AC unit. An attacker could exploit the vulnerability to cause unauthorized firmware to be loaded...

7.5CVSS6.5AI score0.00177EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2023/04/17 12:0 a.m.43 views

CVE-2023-24504 Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server

Electra Central AC unit – Adjacent attacker may cause the unit to connect to unauthorized update server...

7.5CVSS7.7AI score0.00271EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/04/17 12:0 a.m.18 views

Electra Central AC unit 安全漏洞

The Electra Central AC unit is an Electra Central AC unit from Electra. A security vulnerability exists in the Electra Central AC unit. An attacker could exploit the vulnerability to cause the unit to connect to an unauthorized update server...

7.5CVSS6.5AI score0.00271EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2023/04/17 12:0 a.m.26 views

CVE-2023-24501 Electra Central AC unit – Hardcoded Credentials

Electra Central AC unit – Hardcoded Credentials in unspecified code used by the unit...

9.8CVSS9.7AI score0.00621EPSS
SaveExploits0References1
Rows per page
Query Builder