Lucene search
+L

21 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•25 views

EUVD-2020-20852

Malware in sbrugna...

7.5CVSS7.3AI score0.01629EPSS
SaveExploits0References3
RedhatCVE
RedhatCVE
•added 2025/05/22 4:36 p.m.•24 views

CVE-2020-28393

An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4...

7.5CVSS7.2AI score0.01629EPSS
SaveExploits0
ICS
ICS
•added 2024/06/11 12:00 a.m.•59 views

Siemens SCALANCE XM-400, XR-500

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

5.9CVSS7.2AI score0.23509EPSS
SaveExploits0References12
Tenable Nessus
Tenable Nessus
•added 2023/04/11 12:00 a.m.•34 views

Siemens SCALANCE XM-400 and XR-500 Improper Validation of Integrity Check Value (CVE-2021-37182)

A vulnerability has been identified in SCALANCE XM408-4C All versions V6.5, SCALANCE XM408-4C L3 int. All versions V6.5, SCALANCE XM408-8C All versions V6.5, SCALANCE XM408-8C L3 int. All versions V6.5, SCALANCE XM416-4C All versions V6.5, SCALANCE XM416-4C L3 int. All versions V6.5, SCALANCE...

7.5CVSS7AI score0.00644EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2023/03/27 12:00 a.m.•32 views

Siemens SCALANCE XM-400 and XR-500 Devices Incorrect Calculation (CVE-2020-28393)

An unauthenticated remote attacker could create a permanent denial-of- service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4. This plugin only works with...

7.5CVSS7.3AI score0.01629EPSS
SaveExploits0References3
ICS
ICS
•added 2022/08/09 12:00 a.m.•90 views

Siemens SCALANCE

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

6.4AI score
SaveExploits0References10
Positive Technologies
Positive Technologies
•added 2022/08/09 12:00 a.m.•27 views

PT-2022-4147 · Siemens · Scalance W-700 +9

Name of the Vulnerable Software and Affected Versions: SCALANCE M-800 / S615 versions prior to V2.3.1 SCALANCE SC-600 family versions prior to V2.3.1 SCALANCE W-1700 IEEE 802.11ac family versions prior to V2.3.1 SCALANCE W-700 IEEE 802.11ax family versions prior to V2.3.1 SCALANCE W-700 IEEE...

9CVSS6.2AI score0.01012EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
•added 2022/07/06 12:00 a.m.•23 views

OSPF Network Protocol DoS

The vulnerability of the OSPF network protocol implementation in the microcomputer-based switching devices SCALANCE models XM-400 and XR-500 is related to the lack of integrity checks. Exploiting this vulnerability can allow a malicious actor to cause service interruptions remotely...

7.8CVSS7.5AI score0.00644EPSS
SaveExploits0References2Affected Software7
CNVD
CNVD
•added 2022/06/15 12:00 a.m.•127 views

SIEMENS SCALANCE XM-400 and XR-500 OSPF Packet Processing Vulnerability

SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. An OSPF packet handling vulnerability exists in the SIEMENS SCALANCE XM-400 and XR-500, which stems from the implementation of the OSPF protocol in the devic...

7.5CVSS7.2AI score0.00644EPSS
SaveExploits0References1
ICS
ICS
•added 2022/06/14 12:00 a.m.•48 views

Siemens SCALANCE XM-400 and XR-500

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SCALANCE XM-400 and XR-500 Vulnerability: Improper Validation of Integrity Check Value 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to...

7.5CVSS7AI score0.00644EPSS
SaveExploits0References11
CNNVD
CNNVD
•added 2022/06/14 12:00 a.m.•81 views

Siemens SCALANCE security vulnerabilities

SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. An OSPF packet handling vulnerability exists in the SIEMENS SCALANCE XM-400 and XR-500, which stems from the implementation of the OSPF protocol in the devic...

7.5CVSS7.1AI score0.00644EPSS
SaveExploits0References3
osv_cve
osv_cve
•added 2021/05/12 2:15 p.m.•26 views

CVE-2020-28393

An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4...

7.5CVSS7.1AI score0.01629EPSS
SaveExploits0References2
NVD
NVD
•added 2021/05/12 2:15 p.m.•58 views

CVE-2020-28393

An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4...

7.5CVSS0.01629EPSS
SaveExploits0References2
Prion
Prion
•added 2021/05/12 2:15 p.m.•42 views

Denial of service

An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4...

7.1CVSS7.4AI score0.01629EPSS
SaveExploits0References2Affected Software11
CVE
CVE
•added 2021/05/12 1:18 p.m.•94 views

CVE-2020-28393

Siemens SCALANCE XM-400 family and XR-500 family are affected (all versions before v6.4). CVE-2020-28393 describes an unauthenticated, remote DoS caused by an “Incorrect Calculation” (CWE-682) when OSPF is enabled and specially crafted OSPF packets are sent. Mitigation from the public advisories ...

7.5CVSS7.4AI score0.01629EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•13 views

CVE-2020-28393: Incorrect Calculation

An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 All versions prior to v6.4...

7.5CVSS5.8AI score0.01629EPSS
SaveExploits0References2
CNVD
CNVD
•added 2021/05/12 12:00 a.m.•94 views

Siemens SCALANCE XM-400 and XR-500 Devices Denial of Service Vulnerability

SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. A denial of service vulnerability exists in the Siemens SCALANCE XM-400 and XR-500 Devices, which can be exploited by an attacker to create a permanent denia...

7.5CVSS7.3AI score0.01629EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2021/05/12 12:00 a.m.•12 views

PT-2021-11515

Name of the Vulnerable Software and Affected Versions: SCALANCE XM-400 versions prior to v6.4 XR-500 versions prior to v6.4 Description: An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation...

7.5CVSS0.01629EPSS
SaveExploits0References6
CNNVD
CNNVD
•added 2021/05/11 12:00 a.m.•24 views

Multiple Siemens devices have security vulnerabilities

SCALANCE X switches are used to connect industrial components such as programmable logic controllers PLCs or human machine interfaces HMIs. A denial of service vulnerability exists in the Siemens SCALANCE XM-400 and XR-500 Devices, which can be exploited by an attacker to create a permanent denia...

7.5CVSS5.6AI score0.01629EPSS
SaveExploits0References5
ICS
ICS
•added 2021/05/11 12:00 a.m.•59 views

Siemens SCALANCE XM-400 and XR-500 Devices

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE XM-400, XR-500 Vulnerability: Incorrect Calculation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to create...

7.5CVSS7.9AI score0.01629EPSS
SaveExploits0References11
Rows per page