Lucene search
+L

71 matches found

Prion
Prion
added 2014/02/07 4:52 a.m.21 views

Code injection

Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service monitoring-service outage via malformed HTTP requests to port 4999...

5CVSS7.1AI score0.02142EPSS
SaveExploits1References6Affected Software1
Prion
Prion
added 2014/02/07 4:52 a.m.22 views

Directory traversal

Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999...

5CVSS7.1AI score0.03507EPSS
SaveExploits0References6Affected Software1
Prion
Prion
added 2014/02/07 4:52 a.m.24 views

Code injection

The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999...

7.5CVSS8.2AI score0.05261EPSS
SaveExploits1References6Affected Software1
Cvelist
Cvelist
added 2014/02/07 2:00 a.m.35 views

CVE-2014-1697

The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999...

7.6AI score0.05261EPSS
SaveExploits1References6
CVE
CVE
added 2014/02/07 2:00 a.m.67 views

CVE-2014-1698

CVE-2014-1698 is a directory traversal vulnerability in Siemens SIMATIC WinCC OA, affecting versions before 3.12 P002 January. The affected component is the integrated Web server at Port 4999/TCP, allowing remote attackers to read arbitrary files via crafted packets. The ICS advisory confirms mul...

5CVSS6.9AI score0.03507EPSS
SaveExploits0References6Affected Software1
CVE
CVE
added 2014/02/07 2:00 a.m.67 views

CVE-2014-1699

CVE-2014-1699 affects Siemens SIMATIC WinCC OA before version 3.12 P002 January. The vulnerability resides in the integrated Web server on port 4999/TCP and stems from improper input validation, allowing remote attackers to trigger a denial of service (monitoring-service outage) by sending malfor...

5CVSS6.8AI score0.02142EPSS
SaveExploits1References6Affected Software1
Cvelist
Cvelist
added 2014/02/07 2:00 a.m.44 views

CVE-2014-1699

Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service monitoring-service outage via malformed HTTP requests to port 4999...

6.6AI score0.02142EPSS
SaveExploits1References6
Cvelist
Cvelist
added 2014/02/07 2:00 a.m.38 views

CVE-2014-1698

Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999...

6.6AI score0.03507EPSS
SaveExploits0References6
CVE
CVE
added 2014/02/07 2:00 a.m.59 views

CVE-2014-1697

The CVE-2014-1697 entry concerns Siemens SIMATIC WinCC OA prior to version 3.12 P002. The vulnerability lies in the integrated Web server on port 4999, where specially crafted, unauthenticated packets can remotely trigger arbitrary code execution due to improper handling of inputs (code injection...

7.5CVSS7.8AI score0.05261EPSS
SaveExploits1References6Affected Software1
Cvelist
Cvelist
added 2014/02/07 2:00 a.m.37 views

CVE-2014-1696

Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack...

6.4AI score0.01691EPSS
SaveExploits1References4
ICS
ICS
added 2014/01/16 7:00 a.m.223 views

Siemens Industrial Products OpenSSL Heartbleed Vulnerability (Update B)

OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-14-105-03A Siemens Industrial Products OpenSSL Heartbleed Vulnerability that was published April 29, 2014, on the NCCIC/ICS-CERT web site. Siemens reported to ICS-CERT a list of products affected by the OpenSSL...

7.5CVSS8AI score0.99999EPSS
SaveExploits94References10