added 2018/04/19 12:00 a.m.10 views

SIMATIC WinCC OA Operator iOS Information Disclosure Vulnerability

SIMATIC WinCC OA Operator iOS is an application that makes it easy to control SIMATIC WinCC OA devices from a mobile device. An information disclosure vulnerability exists in SIMATIC WinCC OA Operator iOS. It allows an attacker to read unencrypted data from the application's directory. A...

4.6CVSS5.8AI score0.00269EPSS
SaveExploits0References1
ICS
ICS
added 2018/04/19 12:00 a.m.50 views

Siemens SIMATIC WinCC OA Operator IOS App (Update A)

1. EXECUTIVE SUMMARY CVSS v3 4.0 Vendor : Siemens Equipment : SIMATIC WinCC OA iOS App Vulnerability : File and Directory Information Exposure. 2 UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-109-01 Siemens SIMATIC WinCC OA Operator iOS App that...

4.6CVSS4.3AI score0.00269EPSS
SaveExploits0References4
Prion
Prion
added 2018/03/20 2:29 p.m.18 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC WinCC OA UI for Android All versions V3.15.10, SIMATIC WinCC OA UI for iOS All versions V3.15.10. Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache...

3.8CVSS6AI score0.00427EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2018/03/20 2:29 p.m.21 views

CVE-2018-4844

A vulnerability has been identified in SIMATIC WinCC OA UI for Android All versions V3.15.10, SIMATIC WinCC OA UI for iOS All versions V3.15.10. Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache...

6.7CVSS6AI score0.00427EPSS
SaveExploits0References3
CVE
CVE
added 2018/03/20 2:00 p.m.70 views

CVE-2018-4844

Siemens SIMATIC WinCC OA UI for Android and iOS (versions before 3.15.10) contains an improper access control vulnerability. Insufficient limitation of CONTROL script capabilities allows read/write access from one HMI project cache folder to other HMI project cache folders within the app’s sandbo...

6.7CVSS5.9AI score0.00427EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/03/20 2:00 p.m.31 views

CVE-2018-4844

A vulnerability has been identified in SIMATIC WinCC OA UI for Android All versions V3.15.10, SIMATIC WinCC OA UI for iOS All versions V3.15.10. Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache...

6AI score0.00427EPSS
SaveExploits0References2
ICS
ICS
added 2018/03/20 12:00 a.m.56 views

ICSA-18-081-01 Siemens SIMATIC WinCC OA UI Mobile App

CVSS v3 5.1 ATTENTION: Exploitable from an adjacent network. Vendor: Siemens Equipment: SIMATIC WinCC OA UI mobile app Vulnerability: Improper Access Control AFFECTED PRODUCTS Siemens reports that this vulnerability affects the following products: SIMATIC WinCC OA UI for Android: All versions pri...

6.7CVSS6.7AI score0.00427EPSS
SaveExploits0References9
BDU FSTEC
BDU FSTEC
added 2016/07/05 12:00 a.m.11 views

The vulnerability of the automated system for managing technological processes of SIMATIC WinCC OA allows a malicious individual to execute arbitrary codes without going through authentication procedures.

The vulnerability of the SIMATIC Winn CC OAM software relates to errors that occur when processing specially crafted TCP packets. Exploiting this vulnerability allows a malicious individual to execute arbitrary code by sending specially crafted packets to port 4999...

5CVSS6AI score0.05261EPSS
SaveExploits1References14Affected Software1
BDU FSTEC
BDU FSTEC
added 2016/07/05 12:00 a.m.12 views

The vulnerability of the automated system for managing technological processes of SIMATIC WinCC OA allows a malicious individual to bypass the file system without going through the authentication procedures as a regular user.

The vulnerability of the SIMATIC WinCC OA software is related to errors that occur when processing specially crafted TCP packets. Exploiting this vulnerability allows a malicious individual to bypass the file system on the server in the context of the current user, without going through the...

5CVSS5.5AI score0.03507EPSS
SaveExploits0References14Affected Software1
ICS
ICS
added 2014/11/07 7:00 a.m.58 views

Siemens SIMATIC WinCC OA Multiple Vulnerabilities

OVERVIEW Researchers Gleb Gritsai, Ilya Karpov, and Kirill Nesterov of Positive Technologies have identified multiple vulnerabilities in the Siemens SIMATIC WinCC Open Architecture OA application. Siemens has produced updates that mitigate these vulnerabilities. These vulnerabilities could be...

7.5CVSS8AI score0.05261EPSS
SaveExploits3References10
ThreatPost
ThreatPost
added 2014/08/18 2:15 p.m.11 views

Siemens Patches DoS Vulnerability in SIMATIC S7

Siemens released an update for one of its automation systems late last week, patching a denial of service vulnerability in all versions of its SIMATIC S7-1500 CPU prior to V1.6. An advisory on the Industrial Control Systems Cyber Emergency Response Team’s ICS-CERT website warned about the...

0.6AI score
SaveExploits0References4
ThreatPost
ThreatPost
added 2014/07/25 1:32 p.m.13 views

Siemens Patches Five Vulnerabilities in SIMATIC System

Siemens released an update for two builds of its SIMATIC automation system this week, addressing a quintet of vulnerabilities, four of which are remotely exploitable. The German company’s SIMATIC WinCC, a SCADA system and SIMATIC PCS7, a distributed control system DCS are directly affected by the...

0.2AI score
SaveExploits0References4
ThreatPost
ThreatPost
added 2014/07/18 10:49 a.m.14 views

Siemens Working on Patches for OpenSSL Bugs Under Exploit

Siemens says it is working on patches for four critical vulnerabilities in the OpenSSL libraries it uses in a number of its industrial control products, flaws that are being exploited in the wild. The Industrial Control Systems Cyber Emergency Response Team ICS-CERT cautioned too that critical...

2.3AI score
SaveExploits0References5
ThreatPost
ThreatPost
added 2014/04/28 12:03 p.m.12 views

Siemens Update on Heartbleed Patches in ICS, SCADA

Industrial control equipment manufacturer Siemens has produced a security update that mitigates the OpenSSL Heartbleed vulnerability in its eLAN systems and now its WinCC OA supervisory control and data acquisition SCADA software as well. The company is continuing to work on patches to resolve th...

SaveExploits0References9
ThreatPost
ThreatPost
added 2014/04/18 1:20 p.m.14 views

ICS-CERT Warns of Heartbleed Vulnerabilities in Siemens Gear

A number of ICS products from Siemens and Innominate are vulnerable to the OpenSSL heartbleed flaw, some of which do not have updates available yet. The list of products affected by the heartbleed vulnerability continues to grow by the day, with OpenVPN being one of the latest. A researcher on...

0.7AI score
SaveExploits0References3
seebug.org
seebug.org
added 2014/02/12 12:00 a.m.77 views

SIEMENS SIMATIC WinCC Open Architecture不安全密码哈希漏洞

BUGTRAQ ID: 65339 CVECAN ID: CVE-2014-1696 Siemens SIMATIC WinCC 是监测控制和数据采集SCADA及人机界面HMI系统。 SIEMENS SIMATIC WinCC OA 3.12 P002之前版本使用了弱密码哈希算法,存在安全漏洞,远程攻击者通过暴力攻击,即可获取访问权限。 0 Siemens SIMATIC WinCC Open Architecture 3.12 P002 January 厂商补丁: Siemens ------- 目前厂商已经发布了升级补丁以修复这个安全问题,请到厂商的主页下载:...

5CVSS6.4AI score0.01691EPSS
SaveExploits1
NVD
NVD
added 2014/02/07 4:52 a.m.20 views

CVE-2014-1699

Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service monitoring-service outage via malformed HTTP requests to port 4999...

5CVSS6.6AI score0.02142EPSS
SaveExploits1References6
NVD
NVD
added 2014/02/07 4:52 a.m.19 views

CVE-2014-1697

The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999...

7.5CVSS7.6AI score0.05261EPSS
SaveExploits1References6
NVD
NVD
added 2014/02/07 4:52 a.m.26 views

CVE-2014-1696

Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack...

5CVSS6.5AI score0.01691EPSS
SaveExploits1References4
NVD
NVD
added 2014/02/07 4:52 a.m.31 views

CVE-2014-1698

Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999...

5CVSS6.7AI score0.03507EPSS