22198 matches found
Hikvision Web Server 操作系统命令注入漏洞
Hikvision Web Server is a web server of China Hikvision Hikvision. It is used to parse protocols and provide services. An operating system command injection vulnerability exists in Hikvision Web Server that stems from insufficient input validation. An attacker can exploit this vulnerability to...
Apache HTTP Server Code Issue Vulnerability
Apache HTTP Server is the United States Apache Apache Foundation of an open source web server . The server is fast, reliable and can be expanded through a simple API. A security vulnerability exists in Apache HTTP Server version 2.4.48 and earlier, which stems from a malformed request that could...
CVE-2021-36260: Improper Neutralization of Special Elements used in an OS Command
A command injection vulnerability in the web server of some Hikvision product. Due to the insufficient input validation, attacker can exploit the vulnerability to launch a command injection attack by sending some messages with malicious commands...
Exploit for Out-of-bounds Write in Php
This is an exploit module for a bug in php-fpm CVE-2019-11043. The exploit targets a vulnerability in certain nginx + php-fpm configurations, allowing a web user to execute code if the configuration is vulnerable. The exploit works by appending a specially crafted URL to the web server, which...
[SECURITY] Fedora 34 Update: httpd-2.4.49-1.fc34
The Apache HTTP Server is a powerful, efficient, and extensible web server...
ALPINE-CVE-2021-40438
A crafted request uri-path can cause modproxy to forward the request to an origin server choosen by the remote user. This issue affects Apache HTTP Server 2.4.48 and earlier...
UBUNTU-CVE-2021-39275
apescapequotes may write beyond the end of a buffer when given malicious input. No included modules pass untrusted data to these functions, but third-party / external modules may. This issue affects Apache HTTP Server 2.4.48 and earlier...
PT-2021-5091
Name of the Vulnerable Software and Affected Versions Apache HTTP Server versions 2.4.48 and earlier Description The issue is related to malformed requests that can cause the server to dereference a NULL pointer, potentially leading to a denial of service. This can be exploited by a remote attack...
CVE-2021-23856
The web server is vulnerable to reflected XSS and therefore an attacker might be able to execute scripts on a client’s computer by sending the client a manipulated URL...
CVE-2021-38412
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to...
CVE-2021-27391
A vulnerability has been identified in APOGEE MBC PPC P2 Ethernet All versions = V2.6.3, APOGEE MEC PPC P2 Ethernet All versions = V2.6.3, APOGEE PXC Compact BACnet All versions = V2.8, APOGEE PXC Modular BACnet All versions = V2.8, TALON TC Compact BACnet All versions V3.5.3, TALON TC Modular...
PT-2021-4188
Name of the Vulnerable Software and Affected Versions APOGEE MBC PPC P2 Ethernet versions V2.6.3 and later APOGEE MEC PPC P2 Ethernet versions V2.6.3 and later APOGEE PXC Compact BACnet versions prior to V3.5.3 APOGEE PXC Compact P2 Ethernet versions V2.8 and later APOGEE PXC Modular BACnet...
PT-2021-7529
Name of the Vulnerable Software and Affected Versions Modicon M340 CPUs versions prior to V3.40 Modicon M340 X80 Ethernet Communication Modules: BMXNOE0100 H, BMXNOE0110 H, BMXNOC0401, BMXNOR0200H RTU All Versions Modicon Premium Processors with integrated Ethernet Copro: TSXP574634, TSXP575634,...
Siemens SINEC NMS
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Path Traversal, Cross-site Request Forgery 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to manipulate the...
ECOA Building Automation System Cross Site Request Forgery
ECOA Building Automation System Cross-Site Request Forgery Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected version: ECOA ECS Router Controller - ECS FLASH ECOA RiskBuster Terminator - E6L45 ECOA RiskBuster System - RB 3.0.0 ECOA RiskBuster System - TRANE 1.0 ECOA...
ECOA Building Automation System Local File Disclosure
ECOA Building Automation System Local File Disclosure Vulnerability Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected version: ECOA ECS Router Controller - ECS FLASH ECOA RiskBuster Terminator - E6L45 ECOA RiskBuster System - RB 3.0.0 ECOA RiskBuster System - TRANE...
ECOA Building Automation System Configuration Download Information Disclosure
ECOA Building Automation System Configuration Download Information Disclosure Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected version: ECOA ECS Router Controller - ECS FLASH ECOA RiskBuster Terminator - E6L45 ECOA RiskBuster System - RB 3.0.0 ECOA RiskBuster Syst...
ECOA Building Automation System Cookie Poisoning / Authentication Bypass Vulnerabilities
ECOA building automation systems suffer from a cookie poisoning vulnerability that allows for authentication bypass. Many versions are affected. ECOA Building Automation System Cookie Poisoning Authentication Bypass Vendor: ECOA Technologies Corp. Product web page: http://www.ecoa.com.tw Affected...
ECOA Building Automation System Directory Traversal Content Disclosure
Summary 1 The Risk-Terminator Web Graphic control BEMS Building Energy Management System are designed to provide you with the latest in the Human Machine Interface HMI technology, for completely monitoring and controlling management. It may be used singly for small and medium sized facilities,...
ECOA Building Automation System Hard-coded Credentials SSH Access
Summary 1 The Risk-Terminator Web Graphic control BEMS Building Energy Management System are designed to provide you with the latest in the Human Machine Interface HMI technology, for completely monitoring and controlling management. It may be used singly for small and medium sized facilities,...