19879 matches found
CVE-2022-22680
Exposure of sensitive information to an unauthorized actor vulnerability in Web Server in Synology DiskStation Manager DSM before 7.0.1-42218-2 allows remote attackers to obtain sensitive information via unspecified vectors...
CVE-2022-22680
Exposure of sensitive information to an unauthorized actor vulnerability in Web Server in Synology DiskStation Manager DSM before 7.0.1-42218-2 allows remote attackers to obtain sensitive information via unspecified vectors...
CVE-2022-22680
The CVE-2022-22680 issue affects Synology DiskStation Manager (DSM) Web Server prior to version 7.0.1-42218-2, causing exposure of sensitive information to unauthorized actors via unspecified vectors. The vulnerability is classified with CVSS scores up to 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N ...
CVE-2022-22680
Exposure of sensitive information to an unauthorized actor vulnerability in Web Server in Synology DiskStation Manager DSM before 7.0.1-42218-2 allows remote attackers to obtain sensitive information via unspecified vectors...
Siemens SICAM A8000 RTUs Protection Mechanism Failure (CVE-2020-28396)
A vulnerability has been identified in SICAM A8000 CP-8000 All versions V16, SICAM A8000 CP-8021 All versions V16, SICAM A8000 CP-8022 All versions V16. A web server misconfiguration of the affected device can cause insecure ciphers usage by a users browser. An attacker in a privileged position...
Siemens BACnet Field Panels Authentication Bypass Using an Alternate Path or Channel (CVE-2017-9946)
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions V3.5. An attacker with network access to the integrated web server 80/tcp and 443/tcp could bypass the authentication and download sensitive information from the device. This plugi...
Siemens SIMATIC S7-1500 Cross-site Scripting (CVE-2014-2246)
Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. This plugin only works with Tenable.ot. Please visit...
Schneider Electric Modicon Cross-site Scripting (CVE-2018-7831)
An Improper Neutralization of Script-Related HTML Tags in a Web Page Basic XSS vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a...
Siemens SIPROTEC Information Disclosure (CVE-2016-4784)
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Exposure of Sensitive Information to an Unauthorized Actor (CVE-2017-7899)
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00...
Rockwell Automation MicroLogix Cleartext Transmission of Sensitive Information (CVE-2016-9334)
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD,...
Siemens SIMATIC CP 343-1/CP 443-1 Modules and SIMATIC S7-300/S7-400 CPUs (CVE-2016-8672)
A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...
Rockwell Automation MicroLogix Incorrect Permission Assignment for Critical Resource (CVE-2016-9338)
An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD,...
Schneider Electric Web Server on Modicon M340 Out-of-Bounds Read (CVE-2020-7562)
A CWE-125: Out-of-Bounds Read vulnerability exists in the Web Server on Modicon M340, Modicon Quantum and Modicon Premium Legacy offers and their Communication Modules see notification for details which could cause a segmentation fault or a buffer overflow when uploading a specially crafted file ...
Siemens APOGEE and TALON Buffer Copy Without Checking Size of Input (CVE-2021-27391)
A vulnerability has been identified in APOGEE MBC PPC P2 Ethernet All versions = V2.6.3, APOGEE MEC PPC P2 Ethernet All versions = V2.6.3, APOGEE PXC Compact BACnet All versions = V2.8, APOGEE PXC Modular BACnet All versions = V2.8, TALON TC Compact BACnet All versions V3.5.3, TALON TC Modular...
Siemens SIPROTEC Information Disclosure (CVE-2016-4785)
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
Siemens SICAM MMU, SICAM T, and SICAM SGU Improper Neutralization of Script-Related HTML Tags in a Web Page (CVE-2020-10043)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. The web server could allow Cross-Site Scripting XSS attacks if unsuspecting users are tricked into accessing a malicious link. This plugin only works with Tenable.ot. Please...
Siemens SICAM MMU, SICAM T, and SICAM SGU Out-of-Bounds Read (CVE-2020-10037)
A vulnerability has been identified in SICAM MMU All versions V2.05, SICAM SGU All versions, SICAM T All versions V2.18. By performing a flooding attack against the web server, an attacker might be able to gain read access to the device's memory, possibly revealing confidential information. This...
Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2019-13940)
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8F PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8F...
Siemens SIMATIC Cross-site Scripting (CVE-2012-3040)
Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...