Lucene search
+L

2645 matches found

ICS
ICS
•added 2023/01/05 12:00 a.m.•48 views

Hitachi Energy UNEM

1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: UNEM Vulnerabilities: Inadequate Encryption Strength, Use of Hard-coded Cryptographic Key, Cleartext Transmission of Sensitive Information. 2. RISK EVALUATION Successful...

9.8CVSS7.4AI score0.00569EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/12/30 12:00 a.m.•4 views

CVE-2022-48194: Unrestricted Upload of File with Dangerous Type

TP-Link TL-WR902AC devices through V3 0.9.1 allow remote authenticated attackers to execute arbitrary code or cause a Denial of Service DoS by uploading a crafted firmware update because the signature check is inadequate...

8.8CVSS6.5AI score0.33482EPSS
SaveExploits5References3
CNNVD
CNNVD
•added 2022/12/30 12:00 a.m.•19 views

TP-LINK TL-WR902AC 代码问题漏洞

The TP-LINK TL-WR902AC is an Ac750 Travel Router from China P&L TP-LINK. A security vulnerability exists in the TP-LINK TL-WR902AC V3 prior to version 0.9.1, which stems from inadequate signature checking, and can be exploited by an attacker to execute arbitrary code or cause a denial of service...

8.8CVSS8.3AI score0.33482EPSS
SaveExploits5References5
Mend
Mend
•added 2022/12/28 6:16 a.m.•2 views

CVE-2022-46172

authentik is an open-source Identity provider focused on flexibility and versatility. In versions prior to 2022.10.4, and 2022.11.4, any authenticated user can create an arbitrary number of accounts through the default flows. This would circumvent any policy in a situation where it is undesirable...

6.4CVSS0.00545EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/12/26 12:00 a.m.•3 views

CVE-2020-12069: Use of Password Hash With Insufficient Computational Effort

In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device...

7.8CVSS5.8AI score0.00172EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
•added 2022/12/26 12:00 a.m.•11 views

CVE-2020-12069 CODESYS V3 prone to Inadequate Password Hashing

In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device...

7.8CVSS7.7AI score0.00172EPSS
SaveExploits0References4
Cvelist
Cvelist
•added 2022/12/26 12:00 a.m.•52 views

CVE-2020-12069 CODESYS V3 prone to Inadequate Password Hashing

In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device...

7.8CVSS9.3AI score0.00172EPSS
SaveExploits0References4
CVE
CVE
•added 2022/12/26 12:00 a.m.•112 views

CVE-2020-12069

CVE-2020-12069 affects CODESYS V3 products containing CmpUserMgr prior to version 3.5.16.0. The CODESYS Control runtime stores online communication passwords using a weak hashing algorithm, enabling a local attacker with low privileges to gain full control of the device. Publicly documented produ...

7.8CVSS7.8AI score0.00172EPSS
SaveExploits0References4Affected Software1
ICS
ICS
•added 2022/12/22 12:00 a.m.•55 views

Omron CX-Programmer

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Omron Equipment: CX-Programmer Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow arbitrary code execution or loss of sensitive information if a user opens a...

7.8CVSS8AI score0.00252EPSS
SaveExploits0References4
ICS
ICS
•added 2022/12/22 12:00 a.m.•55 views

Priva TopControl Suite

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Priva Equipment: TopControl Suite Vulnerability: Use of Password Hash with Insufficient Computational Effort 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to...

7.5CVSS7.7AI score0.00584EPSS
SaveExploits0References4
ICS
ICS
•added 2022/12/22 12:00 a.m.•62 views

Rockwell Automation Studio 5000 Logix Emulate

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Studio 5000 Logix Emulate Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a malicious user to perform remote code execution,...

7.8CVSS8.1AI score0.00384EPSS
SaveExploits0References4
ICS
ICS
•added 2022/12/20 12:00 a.m.•105 views

Rockwell Automation MicroLogix 1100 and 1400

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: MicroLogix 1100 and 1400 Vulnerabilities: Cross-site Scripting, Improper Restriction of Rendered UI Layers or Frames 2. RISK EVALUATION Successful exploitation of these...

7.5CVSS7.6AI score0.00697EPSS
SaveExploits0References4
ICS
ICS
•added 2022/12/20 12:00 a.m.•63 views

Fuji Electric Tellus Lite V-Simulator

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Fuji Electric Equipment: Tellus Lite V-Simulator Vulnerabilities: Out-of-bounds Write, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute...

7.8CVSS8.5AI score0.00301EPSS
SaveExploits0References4
ICS
ICS
•added 2022/12/15 12:00 a.m.•60 views

Siemens APOGEE/TALON Field Panels

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: APOGEE PXC/TALON TC Vulnerabilities: Predictable Exact Value from Previous Values 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to hijack...

6.5CVSS6.8AI score0.0135EPSS
SaveExploits0References8
ICS
ICS
•added 2022/12/13 12:00 a.m.•41 views

Siemens Mendix Workflow Commons

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

8.1CVSS8.2AI score0.00736EPSS
SaveExploits0References11
ICS
ICS
•added 2022/12/13 12:00 a.m.•62 views

Siemens Multiple Denial of Service Vulnerabilities in Industrial Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7.5CVSS6.4AI score0.00929EPSS
SaveExploits0References12
ICS
ICS
•added 2022/12/13 12:00 a.m.•73 views

Schneider Electric APC Easy UPS Online

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: APC Easy UPS Online Vulnerabilities: Missing Authentication for Critical Function, Unrestricted Upload of File with Dangerous Type, Incorrect Permission Assignment for...

9.8CVSS9.9AI score0.01071EPSS
SaveExploits0References4
ICS
ICS
•added 2022/12/13 12:00 a.m.•61 views

ICONICS and Mitsubishi Electric Products

1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION: Low attack complexity Vendor: ICONICS, Mitsubishi Electric Equipment: ICONICS Product Suite Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to write arbitrary files. 3. TECHNICAL...

7.1CVSS7AI score0.00313EPSS
SaveExploits0References3
ICS
ICS
•added 2022/12/13 12:00 a.m.•53 views

Siemens Simcenter STAR-CCM+

​​As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services ...

7.8CVSS7.8AI score0.00211EPSS
SaveExploits0References12
ICS
ICS
•added 2022/12/05 7:00 a.m.•303 views

Mitsubishi Electric FA Engineering Software (Update C)

1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: GX Works3, MX OPC UA Module Configurator-R Vulnerabilities: Cleartext Storage of Sensitive Information, Use of Hard-coded Password, Insufficiently Protected Credentials,...

9.1CVSS8.7AI score0.0134EPSS
SaveExploits0References11
Rows per page