Lucene search
+L

138 matches found

OpenVAS
OpenVAS
•added 2023/03/07 12:00 a.m.•60 views

Riello UPS / NetMan Detection Consolidation

Consolidation of Riello NetMan network card and the underlying uninterruptible power supply UPS device detections. SPDX-FileCopyrightText: 2023 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders...

5.2AI score
SaveExploits0References1
CNVD
CNVD
•added 2022/10/10 12:00 a.m.•38 views

Generex UPS Adapter CS141 Command Execution Vulnerability

Generex UPS Adapter CS141 is a UPS Uninterruptible Power System adapter from Generex, a German company.A command execution vulnerability exists in Generex UPS Adapter CS141 versions prior to 2.08, which originates from the web of runupdate in /usr/bin/gxservice -update.sh interface fails to...

9.1CVSS5.9AI score0.03149EPSS
SaveExploits2References1
BDU FSTEC
BDU FSTEC
•added 2022/03/28 12:00 a.m.•26 views

APC Smart-UPS Power Supply Authentication Bypass

The vulnerability of microprogrammed power supply systems from APC Smart-UPS models series SMT, SMC, SCL, SMX, SRT, and SRTL is related to deficiencies in authentication procedures. Exploiting this vulnerability can allow an attacker, operating remotely, to arbitrarily alter the behavior of the U...

9.4CVSS8AI score0.05849EPSS
SaveExploits0References3Affected Software18
CNVD
CNVD
•added 2022/03/10 12:00 a.m.•83 views

Authentication bypass vulnerability in several Schneider Electric products

The Schneider Electric APC Smart-UPS SMC Series, among others, is a product of Schneider Electric, a French company. Schneider Electric APC Smart-UPS SMT Series is a line interactive power protection for servers, point-of-sale, routers, switches, hubs and other network devices. Schneider Electric...

9.8CVSS3.5AI score0.12486EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2022/03/09 8:15 p.m.•22 views

CVE-2022-0715

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series SMT Series ID=18: UPS 09.8 and prior / SMT Series...

9.1CVSS5.8AI score0.05849EPSS
SaveExploits0References1
NCSC
NCSC
•added 2022/03/09 12:00 a.m.•21 views

Vulnerabilities fixed in APC UPS systems

Vulnerabilities have been fixed in Uninterruptible Power Supply UPS systems from APC. APC is part of Schneider Electric. These UPS systems are widely used in situations where up-time is very important. The vulnerabilities with reference CVE-2022-22805 and CVE-2022-22806 allow a remote malicious...

9.8CVSS7.9AI score0.12486EPSS
SaveExploits0
CNNVD
CNNVD
•added 2022/03/09 12:00 a.m.•13 views

Schneider Electric 多款产品缓冲区错误漏洞

The Schneider Electric APC Smart-UPS SMC Series, among others, is a product of Schneider Electric, a French company. Schneider Electric APC Smart-UPS SMT Series is a line interactive power protection for servers, point-of-sale, routers, switches, hubs and other network devices. Schneider Electric...

9.8CVSS6.6AI score0.11883EPSS
SaveExploits0References4
NVD
NVD
•added 2022/01/28 8:15 p.m.•49 views

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.1CVSS0.00745EPSS
SaveExploits0References1
NVD
NVD
•added 2022/01/28 8:15 p.m.•43 views

CVE-2021-22815

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 NMC2: AP9630/AP9630CH/AP9630J,...

5.3CVSS0.00768EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2022/01/28 8:15 p.m.•16 views

CVE-2021-22815

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 NMC2: AP9630/AP9630CH/AP9630J,...

5.3CVSS6AI score0.00768EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2022/01/28 8:15 p.m.•13 views

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

6.1CVSS6.5AI score0.00745EPSS
SaveExploits0References2
attackerkb
attackerkb
•added 2022/01/28 8:15 p.m.•10 views

CVE-2021-22812

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power...

6.1CVSS6.5AI score0.00745EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2022/01/28 8:15 p.m.•18 views

CVE-2021-22813

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...

6.1CVSS5.9AI score0.00745EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2022/01/28 8:15 p.m.•15 views

CVE-2021-22815

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 NMC2: AP9630/AP9630CH/AP9630J,...

5.3CVSS6AI score0.00768EPSS
SaveExploits0References2
NVD
NVD
•added 2022/01/28 8:15 p.m.•36 views

CVE-2021-22810

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products:...

6.1CVSS0.00749EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2022/01/28 8:15 p.m.•11 views

CVE-2021-22810

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products:...

6.1CVSS5.9AI score0.00749EPSS
SaveExploits0References1
Prion
Prion
•added 2022/01/28 8:15 p.m.•36 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
Prion
Prion
•added 2022/01/28 8:15 p.m.•35 views

Cross site scripting

A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...

4.3CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software2
CVE
CVE
•added 2022/01/28 7:09 p.m.•92 views

CVE-2021-22815

The CVE-2021-22815 entry covers an Information Exposure vulnerability in Schneider Electric NMC/NMC2/NMC3 embedded devices and related APC equipment. Affected products include 1-phase and 3-phase UPS with NMC2/NMC3 (AP9630/9631/9635 on NMC2; AP9640/9641/9643 on NMC3), NMC2/NMC3-based PDUs, XRDP/X...

5.3CVSS5.2AI score0.00768EPSS
SaveExploits0References1Affected Software1
CVE
CVE
•added 2022/01/28 7:09 p.m.•75 views

CVE-2021-22814

CVE-2021-22814 describes a Cross-site Scripting (CWE-79) vulnerability in Schneider Electric NMC embedded devices (NMC2 and NMC3) that can cause arbitrary script execution when a malicious file is read and displayed. Affected products span multiple Schneider Electric lines: 1-phase and 3-phase UP...

6.1CVSS6.2AI score0.00745EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder