1740 matches found
Mitsubishi Electric MELSEC and MELIPC Denial Of Service (CVE-2020-5531)
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller ModuleQ24DHCCPU-V, Q24DHCCPU-VG User Ethernet port CH1, CH2: First 5 digits of serial number 21121 or before, MELSEC iQ-R Series C Controller Module / C Intelligent Function ModuleR12CCPU-V Ethern...
Rockwell Automation Allen-Bradley PowerMonitor 1000 Authentication Bypass Using an Alternate Path or Channel (CVE-2018-19616)
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-1500 Insufficient Entropy (CVE-2014-2251)
The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors. This plugin only works with...
Schneider Electric Modicon Improper Handling of Exceptional Conditions (CVE-2019-6842)
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the packag...
Schneider Electric Modicon Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2019-6857)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium see security notification for specific versions which could cause a Denial of Service of the controller when reading specific memory blocks using...
General Electric Controller Asset Information
It is possible to obtain attributes of the remote General Electric Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules Missing Authentication For Critical Function (CVE-2018-17924)
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Exposure of Sensitive Information to an Unauthorized Actor (CVE-2017-7899)
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00...
Yokogawa Vnet/IP Open Communication Driver Resource Management Errors (CVE-2018-16196)
Multiple Yokogawa products that contain Vnet/IP Open Communication Driver CENTUM CS 3000R3.05.00 - R3.09.50, CENTUM CS 3000 Entry ClassR3.05.00 - R3.09.50, CENTUM VPR4.01.00 - R6.03.10, CENTUM VP Entry ClassR4.01.00 - R6.03.10, ExaopcR3.10.00 - R3.75.00, PRMR2.06.00 - R3.31.00, ProSafe-RSR1.02.00...
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 Weak Password Requirements (CVE-2017-7903)
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable- logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version...
Yokogawa CENTUM, Exaopc and B/M9000 Stack-based Buffer Overflow (CVE-2014-0782)
Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier,...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2019-6846)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause information disclosure when using the FTP protocol. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2018-13815)
A vulnerability has been identified in SIMATIC S7-1200 All versions, SIMATIC S7-1500 All Versions V2.6. An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be abl...
Rockwell Automation MicroLogix Controllers and RSLogix 500 Software Use of Hard-Coded Cryptographic Key (CVE-2020-6990)
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-16850)
Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14465)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2021-20591)
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules R00/01/02CPU all versions, R04/08/16/32/120ENCPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions allows a remote unauthenticated...
Schneider Electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2018-7838)
A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FT...
Mitsubishi Electric Controller Asset Information
It is possible to obtain attributes of the remote Mitsubishi Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...
Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2252)
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. This plugin only works with Tenable.ot. Please visit...