1740 matches found
Yokogawa CAMS for HIS Violation of Secure Design Principles (CVE-2022-30707)
Violation of secure design principles exists in the communication of CAMS for HIS. Affected products and versions are CENTUM series where LHS4800 is installed CENTUM CS 3000 and CENTUM CS 3000 Small R3.08.10 to R3.09.00, CENTUM series where CAMS function is used CENTUM VP, CENTUM VP Small, and...
ABB REX640 Incorrect Permission Assignment for Critical Resource (CVE-2022-1596)
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node. - Incorrect Permission Assignment for Critical...
Siemens EN100 Ethernet Module Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2022-30937)
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
JTEKT TOYOPUC Missing Authentication For Critical Function (CVE-2022-29951, CVE-2022-29958)
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that...
Emerson DeltaV Distributed Control System Use of Hard-Coded Credentials (CVE-2022-29962, CVE-2022-29963, CVE-2022-29964, CVE-2022-29965, CVE-2022-30261, CVE-2022-30263, CVE-2022-30266)
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that...
Honeywell Safety Manager Missing Authentication For Critical Function (CVE-2022-30313, CVE-2022-30314, CVE-2022-30315, CVE-2022-30316, CVE-2022-30317)
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that...
Honeywell Saia Burgess PG5 PCD Authentication Bypass Using an Alternate Path or Channel (CVE-2022-30319, CVE-2022-30320)
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that...
Omron SYSMAC CS/CJ/CP Series and NJ/NX Series Cleartext Transmission of Sensitive Information (CVE-2022-31204, CVE-2022-31207)
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that...
Rockwell Automation Logix Controllers Uncontrolled Resource Consumption (CVE-2022-1797)
The remote OT product is vulnerable as specified in advisory ICSA-22-144-01. - A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of- service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the targe...
Mitsubishi Electric MELSEC iQ-F Series Improper Input Validation (CVE-2022-25162)
Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/zx=32,64,80, y=T,R, z=ES,DS,ESS,DSS with serial number 17X or later and versions prior to 1.270, Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/zx=32,64,80, y=T,R, z=ES,DS,ESS,DSS with...
Mitsubishi Electric MELSEC iQ-F Series Improper Input Validation (CVE-2022-25161)
Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/zx=32,64,80, y=T,R, z=ES,DS,ESS,DSS with serial number 17X or later and versions prior to 1.270, Mitsubishi Electric Mitsubishi Electric MELSEC iQ-F series FX5U-xMy/zx=32,64,80, y=T,R, z=ES,DS,ESS,DSS with...
Schneider Electric Use of Hard-Coded Cryptographic Key in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25180)
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm...
Rockwell Automation ISaGRAF5 Runtime Use of Hard-Coded Cryptographic Key (CVE-2020-25180)
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm...
Mitsubishi Electric FA Products Cleartext Storage of Sensitive Information (CVE-2022-25160)
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5UC CPU all versions and Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions allows a remote unauthenticated attacker to disclose a file in a legitimate user's product by using previousl...
Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element (CVE-2020-25182)
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft...
Rockwell Automation ISaGRAF5 Runtime Plaintext Storage of a Password (CVE-2020-25184)
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could...
Siemens PROFINET Stack Integrated on Interniche Stack Uncontrolled Resource Consumption (CVE-2022-25622)
A vulnerability has been identified in SIMATIC CFU DIQ All versions, SIMATIC CFU PA All versions, SIMATIC S7-1500 CPU family incl. related ET200 CPUs and SIPLUS variants All versions V2.0.0, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 H V6 C...
Schneider Electric Cleartext Transmission of Sensitive Information in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25178)
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote...
Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal (CVE-2020-25176)
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer IXL protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated...
Schneider Electric Relative Path Traversal in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25176)
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer IXL protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated...